Download Print this page

Performance Curves; Guide To Performance Curves; Curve Conditions - Johnson Controls SABROE WHC 2.1 Installation And Operating Manual

Circulation system for heat pumps and refrigeration compressors

Advertisement

11. Performance curves

11.1 Guide to performance curves

Each pump setting has its own performance curve. However,
AUTO
covers a performance range.
ADAPT
A power curve, P1, belongs to each performance curve. The
power curve shows the pump power consumption in watt at a
given performance curve.

11.2 Curve conditions

The guidelines below apply to the performance curves on the
following pages:
Test liquid: airless water.
The curves apply to a density of ρ = 983.2 kg/m
temperature of 60 °C.
All curves show average values and must not be used as
guarantee curves. If a specific minimum performance is
required, individual measurements must be made.
The curves for speeds I, II and III are marked.
The curves apply to a kinematic viscosity of  = 0.474 mm
(0.474 cSt).
The conversion between head H [m] and pressure p [kPa] has
been made for water with a density of 1000 kg/m
with other densities, for example hot water, the outlet pressure
is proportional to the density.
Curves are obtained according to EN 16297-2.
3
and a liquid
2
/s
3
. For liquids
21