Phoenix Contact FL MGUARD RS2000 TX/TX VPN User Manual
Phoenix Contact FL MGUARD RS2000 TX/TX VPN User Manual

Phoenix Contact FL MGUARD RS2000 TX/TX VPN User Manual

Hide thumbs Also See for FL MGUARD RS2000 TX/TX VPN:

Advertisement

Quick Links

Chipsmall Limited consists of a professional team with an average of over 10 year of expertise in the distribution
of electronic components. Based in Hongkong, we have already established firm and mutual-benefit business
relationships with customers from,Europe,America and south Asia,supplying obsolete and hard-to-find components
to meet their specific needs.
With the principle of "Quality Parts,Customers Priority,Honest Operation,and Considerate Service",our business
mainly focus on the distribution of electronic components. Line cards we deal with include
Microchip,ALPS,ROHM,Xilinx,Pulse,ON,Everlight and Freescale. Main products comprise
IC,Modules,Potentiometer,IC Socket,Relay,Connector.Our parts cover such applications as commercial,industrial,
and automotives areas.
We are looking forward to setting up business relationship with you and hope to provide you with the best service
and solution. Let us make a better world for our industry!
Contact us
Tel: +86-755-8981 8866 Fax: +86-755-8427 6832
Email & Skype: info@chipsmall.com Web: www.chipsmall.com
Address: A1208, Overseas Decoration Building, #122 Zhenhua RD., Futian, Shenzhen, China
  

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FL MGUARD RS2000 TX/TX VPN and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Phoenix Contact FL MGUARD RS2000 TX/TX VPN

  • Page 1 Chipsmall Limited consists of a professional team with an average of over 10 year of expertise in the distribution of electronic components. Based in Hongkong, we have already established firm and mutual-benefit business relationships with customers from,Europe,America and south Asia,supplying obsolete and hard-to-find components to meet their specific needs.
  • Page 2 AUTOMATION User manual UM EN FL MGUARD2 — Order No.: User manual for the hardware and software of FL MGUARD security appliances...
  • Page 3 UM EN FL MGUARD2 Revision: Order No.: — This user manual is valid for: Designation Revision Order No. FL MGUARD RS2000 TX/TX VPN 2700642 FL MGUARD RS4000 TX/TX 2700634 FL MGUARD RS4000 TX/TX VPN 2200515 FL MGUARD SMART2 2700640 FL MGUARD SMART2 VPN...
  • Page 4: Please Observe The Following Notes

    How to contact us Internet Up-to-date information on Phoenix Contact products and our Terms and Conditions can be found on the Internet at: www.phoenixcontact.com Make sure you always use the latest documentation.
  • Page 5 The receipt of technical documentation (in particular user documentation) does not consti- tute any further duty on the part of Phoenix Contact to furnish information on modifications to products and/or technical documentation. You are responsible to verify the suitability and intended use of the products in your specific application, in particular with regard to observ- ing the applicable standards and regulations.
  • Page 6: Table Of Contents

    Operation......................6-1 Management menu .................... 6-4 Network menu ....................6-56 Authentication menu..................6-108 Network Security menu .................. 6-129 CIFS Integrity Monitoring menu ..............6-148 IPsec VPN menu ....................6-164 QoS menu ......................6-207 Redundancy ....................6-218 6.10 Logging menu....................6-234 6.11 Support menu....................6-239 8334_en_01 PHOENIX CONTACT...
  • Page 7 Performing a restart .................... 8-1 Performing a recovery procedure ............... 8-2 Flashing the firmware/rescue procedure ............8-3 Glossary ..........................9-1 10 Technical data ........................10-1 10.1 FL MGUARD RS4000/RS2000 ................ 10-1 ......................10.2 FL MGUARD SMART2 10-2 10.3 Ordering data ....................10-3 PHOENIX CONTACT 8334_en_01...
  • Page 8: Introduction

    Individual rule sets as action (target) of firewall rules (apart from user firewall or VPN firewall) Anti-virus features – CIFS integrity check of network drives for changes to specific file types (e.g., (optional) executable files) – Anti-virus scan connector which supports central monitoring of network drives with virus scanners 8334_en_01 PHOENIX CONTACT...
  • Page 9 Can act as an NTP and DNS server via the LAN interface Support In the event of problems with your FL MGUARD, please contact your dealer. Additional information on the device as well as on release notes and software updates can be found on the Internet at www.phoenixcontact.com. PHOENIX CONTACT 8334_en_01...
  • Page 10: Device Versions

    (at the WAN port of the FL MGUARD), without having to make configuration changes or perform driver installations on the existing system. It is designed for instant use in the office or when traveling. Figure 1-1 FL MGUARD SMART2 8334_en_01 PHOENIX CONTACT...
  • Page 11 DIN rail. The following connectivity options are available FL MGUARD RS4000: (LAN/WAN) FL MGUARD RS2000: (LAN/WAN) TX/TX Ethernet/Ethernet TX/TX VPN Ethernet/Ethernet + VPN TX/TX VPN Ethernet/Ethernet + VPN Figure 1-2 FL MGUARD RS4000/FL MGUARD RS2000 PHOENIX CONTACT 8334_en_01...
  • Page 12: Preliminary User Manualtypical Application Scenarios

    In stealth mode, the FL MGUARD can be positioned between an individual computer and the rest of the network. The settings (e.g., for firewall and VPN) can be made using a web browser under the URL https://1.1.1.1/. No configuration modifications are required on the computer itself. Figure 2-1 Stealth mode 8334_en_01 PHOENIX CONTACT...
  • Page 13: Network Router

    Modem, if the Internet connection is via a serial connected modem (compatible with Hayes or AT command set). For computers in the Intranet, the FL MGUARD must be specified as the default gateway. DSL-Modem/ Router Internet Intranet Figure 2-2 Network router PHOENIX CONTACT 8334_en_01...
  • Page 14: Dmz

    IPsec-capable VPN client software must be installed on the external computers and the operating system must support this functionality. For example, Windows 2000/XP can be used or the computer can be equipped with an FL MGUARD. Internet Intranet Figure 2-4 VPN gateway 8334_en_01 PHOENIX CONTACT...
  • Page 15: Wlan Via Vpn

    The default route of an FL MGUARD usually uses the WAN port. However, in this case the Internet can be accessed via the LAN port: Default gateway in the main building IP address of the default gateway 192.168.1.253 PHOENIX CONTACT 8334_en_01...
  • Page 16: Resolving Network Conflicts

    The 1:1 NAT feature of the FL MGUARD can be used to translate these networks to other networks, thus resolving the conflict. (1:1 NAT can be used in normal routing and in IPsec tunnels.) 8334_en_01 PHOENIX CONTACT...
  • Page 17 FL MGUARD 2 PHOENIX CONTACT 8334_en_01...
  • Page 18: Operating Elements And Leds

    Red ON The alarm output is open due to an error (see “Installing the FL MGUARD RS4000/RS2000” on page 4-3). (The alarm output is interrupted during a restart.) Green ON Connection via modem established INFO – (Not used) 8334_en_01 PHOENIX CONTACT...
  • Page 19 Ethernet status. Indicates the status of the LAN or WAN port. As soon as the device is connected to the relevant network, a continuous light indicates that there is a connection to the network partner in the LAN or WAN. When data packets are transmitted, the LED goes out briefly. PHOENIX CONTACT 8334_en_01...
  • Page 20: Fl Mguard Smart2

    When data packets are transmitted, the LED goes out briefly. 1, 2, 3 Various LED light codes Recovery mode. After pressing the Rescue button. See “Restart, recovery procedure, and flashing the firmware” on page 8-1. 8334_en_01 PHOENIX CONTACT...
  • Page 21 FL MGUARD 2 PHOENIX CONTACT 8334_en_01...
  • Page 22: Startup

    Maximum humidity 95%, non-condensing (FL MGUARD RS4000/FL MGUARD RS2000/FL MGUARD DELTA TX/TX) To avoid overheating, do not expose to direct sunlight or other heat sources. NOTE: Cleaning Clean the device housing with a soft cloth. Do not use abrasive solvents. 8334_en_01 PHOENIX CONTACT...
  • Page 23: Checking The Scope Of Supply

    The FL MGUARD SMART2, FL MGUARD RS4000 or FL MGUARD RS2000 device – Package slip The FL MGUARD RS4000 and FL MGUARD RS2000 also include: – COMBICON plug-in connector for the power supply connection and inputs/outputs (inserted) PHOENIX CONTACT 8334_en_01...
  • Page 24 To remove the FL MGUARD RS4000/RS2000 from the DIN rail, insert a screwdriver horizontally in the locking slide under the housing, pull it down – without tilting the screwdriver – and pull up the FL MGUARD RS4000/RS2000. 8334_en_01 PHOENIX CONTACT...
  • Page 25: Connecting To The Network

    Signal contact + (9 to 36 V) VPN status light Table 4-3 Service 2 plug pin assignment Designation Function CMD V+ Not used None, at present Not used None, at present Not used None, at present Not used None, at present PHOENIX CONTACT 8334_en_01...
  • Page 26: Connecting The Supply Voltage

    The FL MGUARD RS4000/RS2000 is designed for operation with a DC voltage of 9 V DC ... 36 V DC/SELV, 1.5 A maximum. Therefore, only SELV circuits with voltage limitations according to EN 60950-1 may be connected to the supply connections and the alarm contact. 8334_en_01 PHOENIX CONTACT...