CONTENTS About this Manual Troubleshooting Product Storage Disclaimer Intended Use Replacement Decommissioning Intended User Safety Instructions Technical Parameters Network security Symbol Conventions &Vulnerability Disclosure General Requirements EU Declaration of Personnel Requirements Conformity Electrical Safety Installation Environment Requirements Equipment and personnel safety requirements Grounding conductor monitoring...
For information on the disposal of electrical and electronic equipment, please refer to the following website: https://eu.ecoflow.com/pages/electronic-devices-disposal SETTING THE RATED RESIDUAL CURRENT OF THE RESIDUAL-CURRENT DEVICE RCDs (Type A) with a rated residual operating current are recommended to...
(post commissioning) EPO shutdown / Fault, system cannot work System Power-On Electrical energization and LED If the LED indicates a faulty status, visit the EcoFlow Pro app to retrieve the indicator check System Power-Off error code for troubleshooting. LED Indicators...
System Operation OPERATION MODE The PowerOcean Plus energy storage system can work in shutdown, standby, self-check or operating mode. SYSTEM POWER-ON Shutdown PROCEDURE (PV MODULE CONFIGURED) mode Set the BATTERY SWITCH on top of the Junction Box to ON position.
EcoFlow Pro app when the installer performs system commissioning. Or custom the DI values. CUSTOM PARAMETER You can custom the following parameters in Commissioning > Device settings > Customize settings in the EcoFlow Pro app when the installer performs system commissioning. • Connection parameters •...
Page 8
Pull the top screw by hand to remove the fan module. Align the locating pins and place the fan module into the fan position. Disconnect the cable. Secure the top screw. Prepare a new fan and install it on the inverter. To install a new fan: Secure the bottom screws, and lower the handle.
For home owners, to troubleshoot the system: Visit and log in to the EcoFlow app and find the most common FAQ or contact customer support in the Setting > Help and feedback. If the problem persists, contact the EcoFlow technical support team.
Technical Parameters EF HD-P3- EF HD-P3- EF HD-P3- EF HD-P3- Technical parameters 29K9-S1 25K0-S1 20K0-S1 15K0-S1 Max. Input Power (W) 20000 20000 15000 10000 Input Voltage Range(V) 160-1000 MPPT Operating Voltage Range (V) 200-850 Start-up Voltage (V) Nominal Input Voltage (V) PV1 Input Max.
Page 11
Max. Operating Altitude (m) 3000 Cooling Method Intelligent air cooling User Interface LED indicator, EcoFlow app RS485 (for meter) & CAN (for BMS) & Wi-Fi & Bluetooth & WAN & Communication Method Wi-Fi Frequency Range (MHz) 2.4GHz: 2412-2472, 5GHz: 5180-5700, 5745-5825 Maximum Output Power (dBm) <20...
TELEMETRY DATA • Telemetry parameters include home load power consumption, PV production, grid usage, etc., to be revealed to the user via EcoFlow App or web portal. • Telemetry parameters include internal inverter parameters such as current, voltage, temperature, etc., which are used for safety diagnosis of the device.
EcoFlow Inc. RM 401, Plant #1, Runheng Industrial Zone, Fuyuanyi Road, Zhancheng Community,Fuhai Street, Bao'an District,Shenzhen City, Guangdong Province, P.R.China EU Declaration of Conformity We, EcoFlow Inc. ,as Manufacturer, declare under our sole responsibility that the products EcoFlow PowerOcean Plus Hybrid Inverter Product Name: EF HD-P3-29K9-S1,EF HD-P3-25K0-S1,EF HD-P3-20K0-S1,EF HD-P3-15K0-S1 Models: to which this declaration relates, is in compliance with the follow requirements:...