EcoFlow PowerOcean EF HD-P3-6K0-S1 User Manual

EcoFlow PowerOcean EF HD-P3-6K0-S1 User Manual

Hybrid inverter

Advertisement

Quick Links

User Manual
V1.3
EcoFlow PowerOcean Hybrid Inverter
|01

Advertisement

Table of Contents
loading

Summary of Contents for EcoFlow PowerOcean EF HD-P3-6K0-S1

  • Page 1 User Manual V1.3 EcoFlow PowerOcean Hybrid Inverter...
  • Page 2: Table Of Contents

    System Installation Electrical Safety Electrical Connection Installation Environment Re- System Commissioning quirements System Power-On Equipment and personnel safe- EcoFlow App ty requirements System Maintenance Grounding conductor monitor- System Power-Off Routine Maintenance Declaration of the Rated Re- sidual Current of the Residu-...
  • Page 3: Safety Instructions

    If there is a probability of personal injury or equipment damage during op- document. EcoFlow is not liable for any loss caused by the user's failure to erations on the equipment, immediately stop the operations, take feasible use this product in compliance with this user manual.
  • Page 4: Installation Environment Requirements

    DISPOSAL For information on the disposal of electrical and electronic equipment, please visit the following website: https://eu.ecoflow.com/pages/electronic-devices-disposal SETTING THE RATED RESIDUAL CURRENT OF THE RESIDUAL-CURRENT DEVICE RCD with rated residual operating current of 100 mA(AC-GRID) and 30mA (AC-BACKUP) would be recommended if there is additional protec-...
  • Page 5: Checking Before The Installa

    If the equipment has been stored for a long time (more than 6 months), it must be checked and tested by professionals before being put into use. For details about Battery maintenance, see EcoFlow PowerOcean LFP Battery User Manual.  A.
  • Page 6: Appearance

    APPEARANCE LABEL DESCRIPTION ENCLOSURE LABELS ❶ Icon Name Meaning Eletric shock warning Caution, risk of eletric shock Danger to life due to high voltages in the inverter; observe a waiting time of 5 minutes. High voltages that can cause lethal electric shocks are Delayed discharge present in the live components of the inverter.
  • Page 7: Electrical Connection

    By using EcoFlow Products, Applications and Services, you consent to the EcoFlow Term of Use and Privacy Policy, which you can access via the “About” section of the “User” page on the EcoFlow App or on the official Inver ter EcoFlow website at https://www.ecoflow.com/policy/terms-of-use and...
  • Page 8: Technical Parameters

    Technical Parameters Technical parameters EF HD-P3-6K0-S1 EF HD-P3-8K0-S1 EF HD-P3-10K-S1 EF HD-P3-12K-S1 Maximum PV power 10kW 12kW 14kW 16kW Maximum input voltage 1000V d.c. Mppt voltage range d.c. 200~850V d.c. Maximum input current DC Input per MPPT (PV) Maximum short circuit current per MPPT Number of MPPTs Overvoltage category...
  • Page 9: Eu Declaration Of Conformity

    Address: Factory Building A202, Founder Technology Industrial Park, North Side of Songbai Highway, Longteng Community, Shiyan Sub-district, Baoan District, Shenzhen City, Guangdong, China Tel: 0086(0)755-86103589 EU Declaration of Conformity We, EcoFlow Inc. declare under our sole responsibility that the products EcoFlow PowerOcean Hybrid Inverter PRODUCT: EF HD-P3-10K-S1,EF HD-P3-8K0-S1, EF HD-P3-6K0-S1...
  • Page 10 Raccolta carta Copyright ©2023 Ecoflow All Rights Reserved.

Table of Contents