Personnel Requirements Electrical Connection Electrical Safety System Commissioning Installation Environment System Operation Requirements System Power-On Equipment and personnel EcoFlow App safety requirements System Maintenance & Grounding conductor Replacement monitoring System Power-Off Declaration of the Rated Routine Maintenance Residual Current of the...
If there is a probability of personal injury or equipment damage during op- document. EcoFlow is not liable for any loss caused by the user's failure to erations on the equipment, immediately stop the operations, take feasible use this product in compliance with this user manual.
DISPOSAL For information on the disposal of electrical and electronic equipment, please visit the following website: https://eu.ecoflow.com/pages/electronic-devices-disposal SETTING THE RATED RESIDUAL CURRENT OF THE RESIDUAL-CURRENT DEVICE RCD (type A) with rated residual operating current of 100 mA(AC-GRID) and 30mA (AC-BACKUP) would be recommended if there is additional...
If the equipment has been stored for a long time (more than 6 months), it • Not included must be checked and tested by professionals before being put into use. For details about Battery maintenance, see EcoFlow PowerOcean LFP Battery User Manual. - Ground point with...
APPEARANCE LABEL DESCRIPTION ENCLOSURE LABELS ❶ ❷ ❸ Icon Name Meaning ❹ Eletric shock warning Caution, risk of eletric shock Danger to life due to high voltages in the inverter; observe a waiting time of 5 minutes. ❺ High voltages that can cause lethal Delayed discharge electric shocks are present in the live components of the inverter.
Orange By using EcoFlow Products, Applications and Services, you consent to the EcoFlow Term of Use and Privacy Policy, which you can access via the “About” section of the “User” page on the EcoFlow App or on the official EcoFlow...
Follow the in-app instructions to fix the issue. • As end users, you can visit and log in to the EcoFlow user app and find the most common FAQ or contact customer support by tapping the following in sequence Setting-Help and feedback.
Technical Parameters Technical parameters EF HD-P1-3K-S1 EF HD-P1-3.68K-S1 EF HD-P1-4.6K-S1 EF HD-P1-5K-S1 EF HD-P1-6K-S1 Maximum PV Power (W) 9000 9680 10600 11000 12000 Maximum Input Voltage (V) Mppt Voltage Range (V) 90-520 Maximum Input Current per MPPT (A) 18 (single PV input), 16 (dual PV input) DC Input (PV) Maximum Short Circuit Current per MPPT (A)
TELEMETRY DATA • Telemetry parameters include home load power consumption, PV production, grid usage, etc., to be revealed to the user via EcoFlow App or web portal. • Telemetry parameters include internal inverter parameters such as current, voltage, temperature, etc., which are used for safety diagnosis of the device.
Address: RM 401, Plant #1, Runheng Industrial Zone, Fuyuanyi Road, Zhancheng Community, Fuhai Street, Bao'an District, Shenzhen City, Guangdong Province, P.R.China Tel: 0086(0)755-23590789 EU Declaration of Conformity We, EcoFlow Inc. declare under our sole responsibility that the products PRODUCT: EcoFlow PowerOcean Hybrid Inverter MODELS: EF HD-P1-3K-S1, EF HD-P1-3.68K-S1, EF HD-P1-4.6K-S1, EF HD-P1-5K-S1,...