Bogen BCMA 8000 Series Installation Manual
Bogen BCMA 8000 Series Installation Manual

Bogen BCMA 8000 Series Installation Manual

Master clock
Table of Contents

Advertisement

Quick Links

Installation Manual V1
BCMA 8000 Series Master Clock
201.934.8500 P.
201.934.9832 F.
www.bogen.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BCMA 8000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Bogen BCMA 8000 Series

  • Page 1 Installation Manual V1 BCMA 8000 Series Master Clock 201.934.8500 P. 201.934.9832 F. www.bogen.com...
  • Page 2: Table Of Contents

    201.934.8500 P. 201.934.9832 F. www.bogen.com BCMA 8000 Master Clock Table of Contents Table of Contents—2 Table of Contents—3 Wall Mount Installation —4 Rack Mount Installation —5 Installing the Master Clock with the Line Cord Receptacle—6 AC Power Wiring using 14 AWG Romex Cable—6 Rear View of Unit—7...
  • Page 3 201.934.8500 P. 201.934.9832 F. www.bogen.com BCMA 8000 Master Clock Table of Contents Setting the Secondary Time Source—27 Sync-Wire Communication - Programming Clock 1 & 2 Circuits from the LCD Display—28 Setting Daylight Savings Time from the LCD Display—28 Sync-Wire Communication – Protocol Definitions—29 Configuring the Zone Durations from the LCD Display—30...
  • Page 4: Wall Mount Installation -4

    201.934.8500 P. 201.934.9832 F. www.bogen.com Wall Mount Installation Fig 1 1. Place the supplied template on the wall where the master clock is being mounted. 2. Mark the center point of the top right hole. Drill the hole and install the supplied anchor from the mounting kit.
  • Page 5: Rack Mount Installation -5

    201.934.8500 P. 201.934.9832 F. www.bogen.com Rack Mount Installation 1. The master clock is 1U in size. Install the threaded nuts in the desired location in the rack rails. 2. Put the nylon washers on the two screws supplied. 3. Line up the master clock with the threaded nut.
  • Page 6: Installing The Master Clock With The Line Cord Receptacle-6

    201.934.8500 P. 201.934.9832 F. www.bogen.com Before You Get Started Installing the Master Clock with the Line Cord Receptacle *This product is intended for commercial use only and not intended for use in a private residential area Remainder of cord not shown...
  • Page 7: Rear View Of Unit-7

    Clock 1 & 2 Sync-Wire Outputs This terminal block is where connections would be landed for Clock 1 and Clock 2 sync-wire communication relay outputs. RS485 Input/Output This terminal block is where connections would be landed for RS485 communication to and from other Bogen systems.
  • Page 8: Remote Antenna Mounting Instructions-8

    201.934.8500 P. 201.934.9832 F. www.bogen.com Remote Antenna Mounting Instructions 1. Place the supplied template on the wall where the remote antenna is being mounted. 2. Mark the center point of the top right hole. Drill the hole and install the supplied anchor from the mounting kit.
  • Page 9: Before You Get Started

    Zone Each zone is controlled by a relay closure where devices such as bells can be connected. User programming features All 8000 series user programming is to be done by using the 16-button keypad located on the front of the Bogen master clock or via the web interface software upgrade. The keypad is shown below: The LCD display is 20 characters wide and consists of both a top and a bottom line.
  • Page 10: Wire Digital Communication System Connection-10

    201.934.8500 P. 201.934.9832 F. www.bogen.com System Connections – Wired Systems 2 Wire Digital Communication System Connection 18 19 White 110V (EU 240V) Black 24V BCAM Series Analog Clock 24V BCBD 1000 Series Digital Clock BCBD 2000 Series Digital Clock 110V...
  • Page 11: Rs485 Communication System Connection-11

    201.934.8500 P. 201.934.9832 F. www.bogen.com System Connections – Wired Systems RS485 Communication System Connection Black White (EU 240/24VAC) 110V/24V BCRM Series Analog Clock (EU 240/24V) Black/Yellow White/Orange 110V/24V BCBD 1000 Series Digital Clock BCBD 2000 Series Digital Clock (EU 240/24V)
  • Page 12: Sync-Wire Communication System Connection-12

    201.934.8500 P. 201.934.9832 F. www.bogen.com System Connections – Wired Systems Sync-Wire Communication System Connection (EU 240/24VAC) 110V/24V BCAM Series Analog Clock (EU 240/24V) /Blue Black/Yellow White/Orange BCBD 2000 Series Digital Clock (EU 240/24V) 110V/24V BCAM Series Analog Clock (EU 240/24V)
  • Page 13: Once-A-Day Pulse Using Clock 1 Or Clock 2

    201.934.8500 P. 201.934.9832 F. www.bogen.com System Connections – Wired Systems Once-a-day Pulse Using Clock 1 or Clock 2 Intercom, paging system, or other device...
  • Page 14: Sync-Wire 59 Minute Correction-14

    201.934.8500 P. 201.934.9832 F. www.bogen.com Inputs – Sync-Wire Inputs Installation Sync-Wire 59 Minute Correction Dry Contact Closure 110VAC Interface 24VAC Interface (EU 240VAC) N.O. Sync-Wire 58 Minute Corrections 1–4 Dry Contact Closure 110VAC Interface 24VAC Interface (EU 240VAC) N.O. * Please note that we can control most of these clock brands/models, but request that our customers verify the brand/model with us to be certain.
  • Page 15: Sync-Wire National Time/Rauland Input-15

    201.934.8500 P. 201.934.9832 F. www.bogen.com Inputs – Sync-Wire Inputs Installation Sync-Wire National Time/Rauland Input Dry Contact Closure 110VAC Interface 24VAC Interface (EU 240VAC) Sync-Wire Rauland Digital Input Output * Please note that we can control most of these clock brands/models, but request that our customers verify the brand/model with us to be certain.
  • Page 16: Sync-Wire Dukane Digital-16

    201.934.8500 P. 201.934.9832 F. www.bogen.com Inputs – Sync-Wire Inputs Installation Sync-Wire Dukane Digital Sync-Wire Once a Day Pulse Dry Contact Closure * Please note that we can control most of these clock brands/models, but request that our customers verify the brand/model with us to be certain.
  • Page 17: Gps Antenna Installation-17

    Supplied by Bogen: GPS Dome, a 75’ of RG58 or 150’ length of RG59 cabling (refer to Figure 1.1) Not supplied by Bogen: Steel or PVC piping with 1”-14” thread or 3/4” pipe thread, teflon tape, mounting plate and hardware for piping (refer to Figure 1.1)
  • Page 18: Fire Alarm Interface Installation-18

    Fire Alarm Interface Installation The Fire Alarm Interface allows a relay closure to be connected to the BCMA master clock that allows the user to interface the existing fire alarm with the Bogen BCBD 1000 or BCBD 2000 series digital clocks. N.O.
  • Page 19: Error Codes On Led Display-19

    201.934.8500 P. 201.934.9832 F. www.bogen.com Error Codes Error Codes on LED Display When one of the following errors occurs, one of the LED lights located above one of the six characters on the LED display will begin to flash. See figure below indicating the error each flashing light is associated with.
  • Page 20: User Level Programming

    201.934.8500 P. 201.934.9832 F. www.bogen.com User Level Programming Setting the Time from the LCD Display 1) Type in the user level password (default is 1111) at the main screen to enter user level programming. 2) The display should read “Set Time?”, as displayed in Fig 2.1.
  • Page 21: Add Events From The Lcd Screen-21

    201.934.8500 P. 201.934.9832 F. www.bogen.com User Level Programming Add Events from the LCD Screen 1) Type in the user level password (default is 1111) at the main screen to enter user level programming. 2) Press the NO/CANCEL button until the display reads “Add Events?” as shown in Fig 2.3.
  • Page 22: View/Edit Events Programming From The Lcd Display-22

    201.934.8500 P. 201.934.9832 F. www.bogen.com User Level Programming View/Edit Events Programming from the LCD Display 1) Type in the user level password (default is 1111) at the main screen to enter user level programming. 2) Press the NO/CANCEL button until the display reads “View/Edit Events?” as shown in Fig 2.7.
  • Page 23 201.934.8500 P. 201.934.9832 F. www.bogen.com User Level Programming Add Schedule Change from the LCD Display (max. 100) 1) Type in the user level password (default is 1111) at the main screen to enter user level programming. 2) Press the NO/CANCEL button until the display reads “Add Schedule Change?” as shown in Fig 2.9.
  • Page 24: View/Edit Schedule Change From The Lcd Display-24

    201.934.8500 P. 201.934.9832 F. www.bogen.com User Level Programming View/Edit Schedule Change from the LCD Display 1) Type in the user level password (default is 1111) at the main screen tot enter user level programming. 2) Press the NO/CANCEL button until the display reads “View/Edit Schedule Change?” as shown in Fig 2.14.
  • Page 25: Setting 12/24 Hour Mode From The Lcd Display-25

    201.934.8500 P. 201.934.9832 F. www.bogen.com User Level Programming Setting 12/24 Hour Mode from the LCD Display 1) Type in the user level password (default is 1111) at the main screen to enter user level programming. 2) Press the NO/CANCEL button until the screen shows “Set 12/24 Hour Mode?” as shown in Fig 2.19.
  • Page 26: Numeric Messaging From The Lcd Display-26

    201.934.8500 P. 201.934.9832 F. www.bogen.com User Level Programming Numeric Messaging from the LCD Display 1) Type in the user level password (default is 1111) at the main screen to enter user level programming. 2) Press the NO/CANCEL button until the display reads “Send Number Message?” as shown in Fig 2.22.
  • Page 27: Setting The Primary Time Source-27

    201.934.8500 P. 201.934.9832 F. www.bogen.com Technician Level Programming Setting the Primary Time Source 1) Type in 6063 at the main screen to enter the technician level menu mode. 2) Press the NO/CANCEL button until the display reads “Set Pri Time Source?” as shown in Fig 3.1.
  • Page 28 201.934.8500 P. 201.934.9832 F. www.bogen.com Technician Level Programming Sync-Wire Communication - Programming Clock 1 & 2 Circuits from the LCD Display 1) Type in 6063 at the main screen to enter the technician level menu mode. 2) Press the NO/CANCEL button until the screen shows “Change Clock 1 Circuit Selection?” as shown in Fig 3.5.
  • Page 29: Sync-Wire Communication - Protocol Definitions

    201.934.8500 P. 201.934.9832 F. www.bogen.com System Connections – Wired Systems Sync-Wire Communication – Protocol Definitions 1 - 58th minute (1) The hourly correction for 55 seconds every hour from XX:58:05 to XX:59:00. The daily correction (5 a.m. & 5 p.m.) is ten correction cycles sent to the relay (each for 95 seconds) beginning at 5:05:00, 5:07:00, 5:09:00, 5:11:00, 5:13:00, 5:15:00, 5:17:00, 5:19:00, 5:21:00, and 5:23:00.
  • Page 30 201.934.8500 P. 201.934.9832 F. www.bogen.com Technician Level Programming Configuring the Zone Durations from the LCD Display Each zone (relay) has two configurable durations that can be used during the programming of events. The default durations are three and five seconds.
  • Page 31 201.934.8500 P. 201.934.9832 F. www.bogen.com Technician Level Programming RS485 Communication - Setting the Data Rate from the LCD Display 1) Type in 6063 at the main screen to enter the technician level menu mode. 2) Press the NO/CANCEL button until the display reads “Set the RS485 Rate” as shown in Fig 3.12.
  • Page 32 201.934.8500 P. 201.934.9832 F. www.bogen.com Technician Level Programming Setting the Bias Seconds from the LCD Display The bias seconds allows the user to offset how many seconds, plus or minus, the time will be when receiving an input. This field can range between plus or minus 0-9999 seconds.
  • Page 33 201.934.8500 P. 201.934.9832 F. www.bogen.com Technician Level Programming Setting or Viewing the IP Address from the LCD Display 1) Type in 6063 at the main screen to enter the technician level menu mode. 2) Press the NO/CANCEL button until the display reads “Set IP Address?” as shown in Fig 3.19.
  • Page 34 201.934.8500 P. 201.934.9832 F. www.bogen.com Technician Level Programming Setting the Gateway from the LCD Display 1) Type in 6063 at the main screen to enter the technician level menu mode. 2) Press the NO/CANCEL button until the display reads “Set Gateway Address?” as shown in Fig 3.21.
  • Page 35 201.934.8500 P. 201.934.9832 F. www.bogen.com Web Interface Programming *The web interface is an optional feature and is not available on all units. *Please make sure that ports 123 and 80 in both directions are open on the firewall. Accessing the Web Interface (when connected via DHCP) 1) Plug in a patch cable to the unit, and then into a switch on your network.
  • Page 36: Web Interface - Log In

    201.934.8500 P. 201.934.9832 F. www.bogen.com Web Interface Programming Web Interface - Log In Password There are two levels of passwords that will enable the user to access features. The first level is the user level programming that includes features like setting the time, date, adding and editing events and schedule changes. The default password for the user level is 1111.
  • Page 37 201.934.8500 P. 201.934.9832 F. www.bogen.com Web Interface Programming Web Interface - Date/Time Time This field is where the current time is displayed. The time can be edited by clicking within the field, and typing in the desired time. The time must be entered in 24 hour format (HH:MM:SS). After typing in the desired time, click the Submit button to set the time on the unit (if there is no input connected).
  • Page 38 201.934.8500 P. 201.934.9832 F. www.bogen.com Web Interface Programming Web Interface - Events Event List The list will display each event programmed in the master clock. It is sorted by schedule number and then by time. The Edit button on the right, when clicked, will bring the user back to the Add Scheduled Event screen with the existing data already entered in. This list will display ten events per page.
  • Page 39 * This feature provides the Bogen digital clocks with the ability to count down from a preset amount of time. Simply enter a event with a CStart to start the timer and a event with a CStop to stop the timer. The master clock will automatically calculate the difference in time between the CStart and CStop and will start counting down. There...
  • Page 40 201.934.8500 P. 201.934.9832 F. www.bogen.com Web Interface Programming Web Interface - Add/Edit Events (including Countdown mode) continued t y u i Submit and Continue This button, when pressed, will save the current event and will display a new add event screen that has the previous event’s information already stored in the fields.
  • Page 41 201.934.8500 P. 201.934.9832 F. www.bogen.com Web Interface Programming Web Interface - Schedules Schedule Change List This list displays and allows the user to edit a previously entered schedule change. The Edit button, when pressed, will bring the user back to the Add Schedule Change screen with the existing data already filled in.
  • Page 42 201.934.8500 P. 201.934.9832 F. www.bogen.com Web Interface Programming Web Interface - Schedule Change (max. 100) r t y Schedule This field is where the user will enter which schedule they want the master clock to change to. Date This field is where the user will enter which date they want the schedule change to occur.
  • Page 43 201.934.8500 P. 201.934.9832 F. www.bogen.com Web Interface Programming Web Interface - Manual Control Zone Durations These drop-down lists determine what duration the selected zone (relay) will close for, if any. There are five options: N/A, On, Off, Configured Duration 1 and Configured Duration 2. Configured durations 1 & 2 can be set in the Clock Features pages.
  • Page 44: Web Interface - Settings

    201.934.8500 P. 201.934.9832 F. www.bogen.com Web Interface Programming Web Interface - Settings Send Number This field allows the user to designate which number will be sent to the corresponding digital slave clocks. It can be up to four numeric digits.
  • Page 45: Web Interface - System Settings

    201.934.8500 P. 201.934.9832 F. www.bogen.com Web Interface Programming Web Interface - System Settings User Password This field allows the user to enter a new password for the user level programming. The password must be entered twice before being changed. The default is 1111.
  • Page 46 201.934.8500 P. 201.934.9832 F. www.bogen.com Web Interface Programming Web Interface - DST Daylight Saving Time Selection This drop down list gives four options for Daylight Saving Time: • None - When this option is selected, Daylight Saving Time is not applied at all.
  • Page 47: Web Interface Programming

    201.934.8500 P. 201.934.9832 F. www.bogen.com Web Interface Programming Email Email Recipient - This field is where the user name of the email recipient will be inserted. Do not enter the domain and suffix. (correct: johnsmith) (incorrect: johnsmith@domain.com) Email Domain - This field is where the user will enter the domain name of the email server. (i.e. domain.com) Email Server - This field is where the email server address will be placed.
  • Page 48 201.934.8500 P. 201.934.9832 F. www.bogen.com Web Interface Programming Web Interface - Synchronization Input Selection This drop-down list allows the user to select which input will control the master clock. The choices are: • Real Time Clock • 58 Minute Sync_1 •...
  • Page 49 201.934.8500 P. 201.934.9832 F. www.bogen.com Web Interface Programming Web Interface - IP Gateway IP Address* This field allows the user to set the Gateway IP address for the master clock. Subnet Mask* This field allows the user set the Subnet Mask for the master clock.
  • Page 50: Ntp Servers

    201.934.8500 P. 201.934.9832 F. www.bogen.com Web Interface Programming NTP Servers Retry Failed-Server After This field allows the user to specify how many times it will attempt to access the time from a server before it moves on to the next one.
  • Page 51 201.934.8500 P. 201.934.9832 F. www.bogen.com Web Interface Programming Web Interface - IP Status MAC Address This displays the MAC address for the master clock. IP Address This display the IP address for the master clock. Processor Serial Number The displays the serial number of the master clock.
  • Page 52 201.934.8500 P. 201.934.9832 F. www.bogen.com Web Interface Programming Web Interface - Clock Features Display Format This drop-down list allows the user to select whether they want 12 hour or 24 hour mode to be displayed on the LCD and LED.
  • Page 53 201.934.8500 P. 201.934.9832 F. www.bogen.com Web Interface Programming Web Interface - Database Upload Database This button, when pressed, will upload the current schedules and events, and place it in a file for backup purposes. Browse File This button, when pressed, will allow the user to browse for the saved .db file that contains the saved events and schedules.
  • Page 54: Frequently Asked Questions

    The BCMA can accept an input from a (S)NTP server, 59 minute correction, four different versions of the 58 minute correction, National Time/ Rauland, Dukane digital, Rauland digital, Bogen Wireless Repeater, Once a Day pulse, GPS and Bogen’s RS485 protocol.
  • Page 55: Troubleshooting

    201.934.8500 P. 201.934.9832 F. www.bogen.com Troubleshooting The master clock will not power up. What do I do? Make sure the power cord is securely connected to the power outlet and to the back of the BCMA master clock. Upon being connected to power, the master clock should boot up instantly.
  • Page 56: Industry Canada

    CET appareil numérique de la classe B est conforme á la norme NMB-003 du Canada. CE Declaration of Conformity We, Bogen Communications certify and declare under our sole responsibility that the BCMA 8000 conform with the essential requirements of the EMC Directive 2004/108.EC and LVD 2006/95/EC, based on the following standards applied:...