Bogen 3000 Series Installation Manual

Bogen 3000 Series Installation Manual

Master clock

Advertisement

Installation Manual V3
BCMA 3000 Series Master Clock
Bogen Communications
201.934.8500 P.
50 Spring Street
201.934.9832 F.
Ramsey, NJ 07446
www.bogen.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Bogen 3000 Series

  • Page 1 Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Installation Manual V3 BCMA 3000 Series Master Clock...
  • Page 2: Table Of Contents

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com BCMA 3000 Master Clock Table of Contents Installation Instructions Setting the RS485 Data Rate Wall Mount 3 Setting the User Level Password Rack Mount 4 Setting the Bias Seconds...
  • Page 3: Wall Mount

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Wall Mount Installation Fig 1 1. Remove the cover of the wiring panel (Fig 1). 2. Mark the four drilling points on the wall based on the drawing above.
  • Page 4: Rack Mount

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Rack Mount Installation 1. The master clock is 1U in size. Install the threaded nuts in the desired location in the rack rails. 2. Put the nylon washers on the two screws supplied.
  • Page 5: Before You Get Started

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Before You Get Started Installing the Master Clock with the Line Cord Receptacle Remainder of cord not shown Caution! Do not plug in the power cord until the following steps are completed.
  • Page 6: Rear View Of Unit

    RS485 Input/Output This terminal block is where connections would be landed for RS485 communication to and from other Bogen systems. Inputs This terminal block is where connections would be landed to use the BCMA as a slave clock when being controlled by another system.
  • Page 7: Remote Antenna Mounting Instructions (Rack Mount Only)

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Remote Antenna Mounting Instructions 1. Remove the cover of the wiring panel. 2. Mark the four drilling points on the wall based on the drawing above. 3. Drill the holes for the anchors supplied in the mounting kit at the designated markings from step 1.
  • Page 8: Basic Information

    Zone Each zone is controlled by a relay closure which devices such as bells can be connected. User programming features All 3000 series user programming is to be done by using the 16-button keypad located on the front of the Bogen master clock. The keypad is shown below: The LCD display is 20 characters wide and consists of both a top and a bottom line.
  • Page 9 Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com System Connections – Wired Systems 2 Wire Digital Communication BCAM Series 24V Analog Clock 24V BCBD 1000 Series Digital Clock BCBD 2000 Series Digital Clock BCAM Series 24V Analog Clock...
  • Page 10: Wired Systems - Rs485 Communication

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com System Connections – Wired Systems RS485 Communication BCRM Series 24V/110V Analog Clock 24V/110V BCBD 1000 Series Digital Clock BCBD 2000 Series Digital Clock BCRM Series 24V/110V Analog Clock...
  • Page 11: Wired Systems - Sync-Wire Communication

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com System Connections – Wired Systems Sync-Wire Communication BCAM Series 110V/24V Analog Clock BCBD 2000 Series Digital Clock BCAM Series 110V/24V Analog Clock...
  • Page 12 Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Inputs – Sync-Wire Inputs Installation 59 Minute Correction Dry Contact Closure 110VAC Interface 24VAC Interface N.O. 58 Minute Corrections 1–4 Dry Contact Closure 110VAC Interface 24VAC Interface...
  • Page 13 Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Inputs – Sync-Wire Inputs Installation National Time/Rauland Dry Contact Closure 110VAC Interface 24VAC Interface Rauland Digital Input Output...
  • Page 14 Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Inputs – Sync-Wire Inputs Installation Dukane Digital Once a Day Pulse Dry Contact Closure...
  • Page 15: Fire Alarm Input

    Fire Alarm Interface Installation The Fire Alarm Interface allows a relay closure to be connected to the BCMA master clock that allows the user to interface the existing fire alarm with the Bogen BCBD 1000 or BCBD 2000 series digital clocks. N.O.
  • Page 16: Setting The Time

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com User Level Programming Setting the Time from the LCD Display 1) Type in the user level password (default is 1111) at the main screen to enter user level programming.
  • Page 17: Add Events

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com User Level Programming Add Events from the LCD Screen 1) Type in the user level password (default is 1111) at the main screen to enter user level programming.
  • Page 18: View/Edit Events

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com User Level Programming View/Edit Programming from the LCD Display 1) Type in the user level password (default is 1111) at the main screen to enter user level programming.
  • Page 19: Add Schedule Change

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com User Level Programming Add Schedule Change from the LCD Display 1) Type in the user level password (default is 1111) at the main screen to enter user level programming.
  • Page 20: View/Edit Schedule Change

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com User Level Programming View/Edit Schedule Change from the LCD Display 1) Type in the user level password (default is 1111) at the main screen tot enter user level programming.
  • Page 21: 12/24 Hour Mode

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com User Level Programming Setting 12/24 Hour Mode from the LCD Display 1) Type in the user level password (default is 1111) at the main screen to enter user level programming.
  • Page 22: Numeric Messaging

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com User Level Programming Numeric Messaging from the LCD Display 1) Type in the user level password (default is 1111) at the main screen to enter user level programming.
  • Page 23: Primary Time Source

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Technician Level Programming Setting the Primary Time Source 1) Type in 6063 at the main screen to enter the technician level menu mode. 2) Press the NO/CANCEL button until the display reads “Set Pri Time Source?” as shown in Fig 3.1.
  • Page 24: Secondary Time Source

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Technician Level Programming Sync-Wire Communication - Programming Clock 1 & 2 Circuits from the LCD Display 1) Type in 6063 at the main screen to enter the technician level menu mode.
  • Page 25 Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com System Connections – Wired Systems Sync-Wire Communication – Protocol Definitions 58th minute (1) The hourly correction for 55 seconds every hour from XX:58:05 to XX:59:00. The daily correction (5 a.m. & 5 p.m.) is ten correction cycles sent to the relay (each for 95 seconds) beginning at 5:05:00, 5:07:00, 5:09:00, 5:11:00, 5:13:00, 5:15:00, 5:17:00, 5:19:00, 5:21:00, and 5:23:00.
  • Page 26: Setting The Zone Durations

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Technician Level Programming Configuring the Zone Durations from the LCD Display Each zone (relay) has two configurable durations that can be used during the programming of events. The default durations are three and five seconds.
  • Page 27: Setting The Rs485 Data Rate

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Technician Level Programming RS485 Communication - Setting the Data Rate from the LCD Display 1) Type in 6063 at the main screen to enter the technician level menu mode.
  • Page 28: Setting The Bias Seconds

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Technician Level Programming Setting the Bias Seconds from the LCD Display The bias seconds allows the user to offset how many seconds, plus or minus, the time will be when receiving an input. This field can range between plus or minus 0-7500 seconds.
  • Page 29: Setting The Ip Address

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Technician Level Programming Setting the IP Address from the LCD Display 1) Type in 6063 at the main screen to enter the technician level menu mode. 2) Press the NO/CANCEL button until the display reads “Set the IP Address?” as shown in Fig 3.19.
  • Page 30: Setting The Gateway

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Technician Level Programming Setting the Gateway from the LCD Display 1) Type in 6063 at the main screen to enter the technician level menu mode. 2) Press the NO/CANCEL button until the display reads “Set the Gateway?” as shown in Fig 3.21.
  • Page 31: Web Interface Programming

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Web Interface Programming The web interface is an optional feature and is not available on all units. Please make sure that ports 123 and 80 are open on the firewall.
  • Page 32: Log In

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Web Interface Programming Log In Password There are two levels of passwords that will enable the user to access features. The first level is the user level programming that includes features like setting the time, date, adding and editing events and schedule changes.
  • Page 33: Main Menu

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Web Interface Programming Main Menu Schedule Events This link will access the Schedule Events View/Edit/Add page which allows the user to add new events to a schedule, view existing events or edit existing events.
  • Page 34: View/Edit/Add Events

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Web Interface Programming View/Edit Programming Event List The list will display each event programmed in the master clock. It is sorted by schedule number and then by time. The Edit button on the right, when clicked, will bring the user back to the Add Scheduled Event screen with the existing data already entered in.
  • Page 35: Adding An Event/Count-Down Mode

    * This feature provides the Bogen digital clocks with the ability to count down from a preset amount of time. Simply enter a event with a CStart to start the timer and a event with a CStop to stop the timer. The master clock will automatically calculate the difference in time between the CStart and CStop and will start counting down. There...
  • Page 36 Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Web Interface Programming Add Programming/Countdown Mode (cont.) Submit and Continue This button, when pressed, will save the current event and will display a new add event screen that has the previous event’s information already stored in the fields.
  • Page 37: View/Edit/Add Schedule Change

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Web Interface Programming View/Edit Schedule Change Schedule Change List This list displays and allows the user to edit a previously entered schedule change. The Edit button, when pressed, will bring the user back to the Add Schedule Change screen with the existing data already filled in.
  • Page 38: Adding A Schedule Change

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Web Interface Programming Add Schedule Change Schedule This field is where the user will enter which schedule they want the master clock to change to. Date This field is where the user will enter which date they want the schedule change to occur.
  • Page 39: Manual Control

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Web Interface Programming Manual Control Zone Durations These drop-down lists determine what duration the selected zone (relay) will close for, if any. There are five options: N/A, On, Off, Configured Duration 1 and Configured Duration 2.
  • Page 40 Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Web Interface Programming Individual Settings - BELL and Numeric Messaging Send Number This field allows the user to designate which number will be sent to the corresponding digital slave clocks. It can be up to four numeric digits.
  • Page 41: Technician Level Menu

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Web Interface Programming Technician Level Menu System Settings This link, when clicked, will enter the System Settings pages. These pages include the user password, the RS485 data rate, setting the offset, the input selection, setting Clock #1 and Clock #2 sync-wire protocol outputs and resetting the unit back to manufacturer’s default settings.
  • Page 42: System Settings

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Web Interface Programming System Settings Page 1 User Password This field allows the user to enter a new password for the user level programming. The default is 1111.
  • Page 43 Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Web Interface Programming System Settings Page 2 Input Selection This drop-down list allows the user to select which input will control the master clock. The choices are: •...
  • Page 44: Ip Settings

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Web Interface Programming IP Settings Page 1 Gateway IP Address This field allows the user to set the Gateway IP address for the master clock. Subnet Mask This field allows the user set the Subnet Mask for the master clock.
  • Page 45 Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Web Interface Programming IP Settings Page 2 Retry Failed-Server After This field allows the user to specify how many times it will attempt to access the time from a server before it moves on to the next one.
  • Page 46 Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Web Interface Programming IP Settings Page 3 MAC Address This displays the MAC address for the master clock. IP Address This display the IP address for the master clock.
  • Page 47: Clock Features

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Web Interface Programming Clock Features Display Format This drop-down list allows the user to select whether they want 12 hour or 24 hour mode to be displayed on the LCD and LED.
  • Page 48: Database Maintenance

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Web Interface Programming Database Maintenance Upload Database This button, when pressed, will upload the current schedules and events, and place it in a file for backup purposes.
  • Page 49: Frequently Asked Questions

    What is the maximum length I can go with the GPS cable? When the GPS option is purchased, a 75 foot cable comes standard with the unit. This is Bogen’s recommended longest distance. Is there a Converter option like there was in the BCSM and the BCGPS? No, the Converter Box should be purchased separately from the unit when using a two wire digital communication system.
  • Page 50: Troubleshooting

    Bogen Communications 201.934.8500 P. 50 Spring Street 201.934.9832 F. Ramsey, NJ 07446 www.bogen.com Troubleshooting The master clock will not power up. What do I do? Make sure the power cord is securely connected to the power outlet and to the back of the BCMA master clock. Upon being connected to power, the master clock should boot up instantly.