144 V float voltage . discharge from one short circuit . Serious burns, shock, or material fusing may occur . module with 16 V float voltage . XLHV MODULE SUPERCAPACITOR INSTRUCTION MANUAL ELX1407 December 2024 www.eaton.com/supercapacitors...
. Either high ambient temperature or high cell temperature due to high current can also be where: managed with forced air cooling . Please consult with Eaton I = RMS current (A) applications engineers at ELXTechSupport@eaton .com Resr = DC equivalent series resistance (Ω)
Figure 3. Front panel with mounting holes . Front panel should be secured to a standard 19” rack using M6 hex head bolts . Note: Series or parallel configurations have not been evaluated for UL810a. Please consult with Eaton applications engineers at Electrical ELXTechSupport@eaton.com for additional support.
. Please The power provided on COM IN and COM OUT for the CMS contact an Eaton representative for assistance in selecting a also functions to power CANbus communications . fuse . Observe polarity indicated on module . Reverse polarity operation of the module(s) can shorten the useful life of the module .
Eaton . The user may use other software applications to ID will be different for each module . By default, following accomplish the same functions .
Page 8
Product serial number . For the above product serial number 0x2195A9, CAN Functional Response Id is 0x22195A9 . The corresponding response for module IDs 2195A9 and 2195AA is shown in Figure 12 . XLHV MODULE SUPERCAPACITOR INSTRUCTION MANUAL ELX1407 December 2024 www.eaton.com/supercapacitors...
. Modscan64 is a product of WinTECH Software . The software is not licensed by or necessarily recommended by Eaton . The user may use other software These messages are updated every 1 second if there applications to accomplish the same functions .
Page 10
°C corresponding to the IP address as shown in Table 5. temperature Module voltage UINT32 CMS fault UINT16 No units CMS warning UINT16 No units Table 7. Modbus register definitions . XLHV MODULE SUPERCAPACITOR INSTRUCTION MANUAL ELX1407 December 2024 www.eaton.com/supercapacitors...
The module will report overvoltage warnings . Allow module to idle and self discharge for 45 minutes • or until no overvoltage warnings are reported . Resume normal operation . • XLHV MODULE SUPERCAPACITOR INSTRUCTION MANUAL ELX1407 December 2024 www.eaton.com/supercapacitors...
Firmware license agreement Unless otherwise prescribed in an agreement, any software included in an Eaton product delivered to a buyer is licensed and not sold to the buyer . The license is nonexclusive and limited to only the buyer’s internal use with the Eaton product . Eaton retains for itself or its suppliers all title, ownership and intellectual property rights to any software delivered .
Need help?
Do you have a question about the XLHVS1020944C0B00 and is the answer not in the manual?
Questions and answers