Beurer BM 48 Instructions For Use Manual
Beurer BM 48 Instructions For Use Manual

Beurer BM 48 Instructions For Use Manual

Upper arm blood pressure monitor
Hide thumbs Also See for BM 48:

Advertisement

Quick Links

BM 48
EN Upper arm blood pressure monitor
Instructions for use

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BM 48 and is the answer not in the manual?

Questions and answers

Summary of Contents for Beurer BM 48

  • Page 1 BM 48 EN Upper arm blood pressure monitor Instructions for use...
  • Page 2 4 x 1,5 V AAA (LR03)
  • Page 3: Table Of Contents

    ENGLISH Read these instructions for use carefully. Observe the warnings and safety notes. Keep these instructions for use for fu- ture reference. Make the instructions for use accessible to other users. If the device is passed on, provide the instructions for use to the next user as well.
  • Page 4 Separate the product and packaging elements and  CAUTION dispose of them in accordance with local regulations. Indicates a potentially impending danger. If it is not avoided, slight or minor injuries may occur. Protected against solid foreign objects 12.5 mm in Product information IP20 diameter and larger...
  • Page 5: Intended Use

    Contraindications Atmospheric pressure limitation  WARNING Importer symbol • Do not use the blood pressure monitor on newborns, children or pets. • Persons with reduced physical, sensory or mental capabilities should be supervised by a person responsible for their safety 3.
  • Page 6: General Precautions

    your measured values with your doctor and never make your • Place the cu on the upper arm only. Do not place the cu on own medical decisions based on them (e.g. regarding medi- other parts of the body. cine doses). •...
  • Page 7: Notes On Handling Batteries

    • Do not use the device in the vicinity of strong electromag- • Never mix batteries of di erent manufacturers, capacities (new netic fields and keep it away from radio systems or mobile and used), size, or type within a device. telephones.
  • Page 8: Device Description

    • The device may not be fully usable in the presence of electro- Information on the display magnetic disturbances. This could result in issues such as error ® Low battery indicator Symbol for Bluetooth messages or the failure of the display/device. connection •...
  • Page 9: Establishing A Bluetooth ® Connection

    • Start the app. • Do not take a measurement within 30 minutes of eating, drink- • Select BM 48 in the app and follow the instructions. ing, smoking or exercising. • The transfer starts automatically after a successful measure- •...
  • Page 10: Adopting The Correct Posture

    • If you want to take several measurements in succession, al- • Place your arm on a surface ways make sure that you leave 5 minutes between each meas- • Place your feet flat on the ground next to one another. urement.
  • Page 11: Cardiac Arrhythmia

    • Blood pressure is always stated in the form of two values: Measured blood pres- Risk - The highest pressure is the systolic blood pressure. This sure value range Classification indicator occurs when the heart muscle contracts and blood is Systolic Diastolic colour...
  • Page 12 Low blood pressure Indicates that the value was obtained when the user’s circulatory system was not su ciently at  WARNING rest. The blood pressure values measured in this case generally do not represent the blood pressure Low blood pressure (hypotension) can be a health hazard and at rest.
  • Page 13: Cleaning And Maintenance

    REPLACEMENT PARTS error. correctly connected and that Accessories and/or replacement parts are available at you do not move or speak. www.beurer.de, under “Service”. Please state the corresponding An error oc- Please wait one minute and re- order number. curred during the peat the measurement.
  • Page 14: Disposal

    The batteries are Insert new batteries into the 11. TECHNICAL SPECIFICATIONS nearly flat. device. Type BM 48/1 Model BM 48 10. DISPOSAL Measurement Oscillometric, non-invasive blood pressure Repairing and disposing of the device method measurement on the upper arm •...
  • Page 15: Mains Adapter

    100 – 240 V, 50 – 60 Hz, 0.5 A max Classification Internal power supply, IP 20 no AP or APG, continuous operation Output 5 V DC, 1 A, in conjunction with Beurer blood Blood pressure: Application part, type BF pressure monitors only ®...
  • Page 16: Guarantee/Service

    The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Beurer GmbH is under license. Other trademarks and trade names are those of their respective owners. Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a service mark of Apple Inc., registered in the U.S.

Table of Contents