The manual involves the function, use method, installation and maintenance of the step driver. The contents described in the manual are only applicable to Xinje's DP3L1 series stepping driver products. Notice to user This manual is applicable to the following personnel: ...
Catalog 1.PRODUCT INTRODUCTION ..........................1 1-1. N ..............................1 AMING RULE 1-2. P ..............................1 ERFORMANCE 1-3. A ............................1 PPLICATION FIELD 1-4. E ............................2 LECTRIC FEATURES 1-5. S ............................2 AFETY PRECAUTIONS 2. INSTALLATION AND WIRING ........................... 3 2-1.
1.Product introduction 1-1. Naming rule DP3L1 - 56 5 - IO ① ② ③ ④ ①: DP3L1 series open loop stepping driver ②: Driver output maximum peak current 5.6A ③: The maximum supply voltage of the driver is 50VDC ④: External analog quantity adjust speed 1-2.
1-4. Electric features Item DP3L1-565 DP3L1-565-IO Input power supply (VDC) 20-50 Output peak current (A) 1.4-5.6 Matched motor (base) 42/57 Outline dimension (mm) 75*105*27.8 Step pulse frequency (Hz) 200K Potentiometer specification 0~10K (KΩ) Control signal input voltage 5~24 (Hardware 1.0.00 version support 24VDC; Hardware (VDC)...
2. Installation and wiring 2-1. Installation 2-1-1 Outline dimension ⚫ DP3L1-565 Unit: mm ⚫ DP3L1-565-IO Unit: mm 2-1-2 Installation environment The reliable working temperature of the driver is usually within 60℃ and that of the motor is within 80℃. To ensure that the driver works within the reliable working temperature range, the driver should be installed in the electric cabinet with good ventilation and proper protection.
forced heat dissipation. Avoid being used in dust, oil mist, corrosive gas, high humidity and strong vibration. 2-2. Wiring 2-2-1 Typical wiring diagram ⚫ DP3L1-565 PUL+ PUL- Pulse DIR+ Direction DIR- ENA+ Enable ENA- Error output DC power +20~+50V Motor ⚫...
2-2-2 Wiring notice (1) In order to prevent the driver from being interfered, it is suggested that the control signal should use twisted shielded wire, and the shielding layer should be short circuited with the ground wire. Except for special requirements, the shielded wire of the control signal cable should be single ended grounded: one end of the upper computer of the shielded wire should be grounded, and the driver end of the shielded wire should be suspended.
3. Driver interface Signal indicator Green light: Power Red light: Alarm Control signal interface DIP switch Strong electricity interface 3-1. Control signal interface 3-1-1 Function Signal Function Explanation PUL+ Pulse The rising edge is valid, and the hardware version 1.0.00 supports 24VDC; Hardware control PUL-...
control Hardware version 1.0.00 supports 24VDC; Hardware version 1.0.01 supports signal 5~24VDC. DIR- The initial running direction of the motor depends on the wiring of the motor. Exchanging any phase can change the initial running direction of the motor. The port can be externally connected with an adjustable potentiometer (recommend Potentiomet 0-10K ), the voltage is provided by the driver internally, and the speed range is selected er speed...
Page 11
⚫ DP3L1-565-IO IO signal Note: Hardware version 1.0.00 supports 24VDC; Hardware version 1.0.01 supports 5~24VDC. The resistance ranges of the potentiometer recommended is 0~10KΩ.
3-2. Strong electricity interface 3-2-1 Function Interface Function Explanation DC power supply DC power supply ground ground Positive pole of DC +V Select the voltage according to the demand power supply A+,A- Motor phase A coil Exchange A+, A-, can change the motor operation direction B+,B- Motor phase B coil Exchange B+, B-, can change the motor operation direction...
4. DIP switch DP3L1 series driver adopts 8-digit DIP switch to set subdivision precision, dynamic current and static half current. Detailed description is as follows: ⚫ DP3L1-565 Dynamic current Half/full current Subdivision precision ⚫ DP3L1-565 -IO Dynamic current High/low acceleration/deceleration Subdivision precision 4-1.
5. Protection function The green LED is the power indicator. When the driver is powered on, the LED is always on; When the drive is powered off, the LED goes off. The red LED is the fault indicator. When there is a fault, the indicator will flash continuously, then stop for one second, and then flash continuously;...
6. Common troubleshooting Fault Reason Solution Check the power supply Power supply system error circuit The power light doesn't work Increase the power supply Low supply voltage voltage The current setting is too small Set suitable current The subdivision is too large Set suitable subdivision Protection circuit action Power on again...
Page 18
WUXI XINJE ELECTRIC CO., LTD. No.816, Jianzhu West Road, Binhu District, Wuxi City, Jiangsu Province, China Tel: 400-885-0136 Fax: (510) 85111290 www.xinje.com...
Need help?
Do you have a question about the DP3L1-565 Series and is the answer not in the manual?