SMC Networks 6924MT - annexe 1 Installation Manual

Stackable fast ethernet switch
Hide thumbs Also See for 6924MT - annexe 1:
Table of Contents

Advertisement

Quick Links

TigerStack 100
Stackable Fast Ethernet Switch
N 24 100BASE-FX MT-RJ ports
N Optional 100BASE-FX or 1000BASE-X modules
N Optional stack module for linking up to four units
N 8.8 Gbps of aggregate switch bandwidth
N Support for redundant power unit
N Up to five port trunks per switch
N Port mirroring for non-intrusive analysis
N QoS support for two-level priority
N Full support for IEEE 802.1Q VLANs
N IP Multicasting with IGMP Snooping
N Manageable via console, Web, SNMP/RMON

Installation Guide

SMC6924MT

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 6924MT - annexe 1 and is the answer not in the manual?

Questions and answers

Summary of Contents for SMC Networks 6924MT - annexe 1

  • Page 1: Installation Guide

    TigerStack 100 Stackable Fast Ethernet Switch N 24 100BASE-FX MT-RJ ports N Optional 100BASE-FX or 1000BASE-X modules N Optional stack module for linking up to four units N 8.8 Gbps of aggregate switch bandwidth N Support for redundant power unit N Up to five port trunks per switch N Port mirroring for non-intrusive analysis N QoS support for two-level priority...
  • Page 3 TigerStack 100 Installation Guide From SMC’s Tiger line of feature-rich workgroup LAN solutions 38 Tesla Irvine, CA 92618 September 2002 Pub. # F2.47 150200025600A R01 Phone: (949) 679-8000...
  • Page 4 Irvine, CA 92618 All rights reserved. Printed in Taiwan Trademarks: SMC is a registered trademark; and EZ Switch, TigerStack and TigerStack are trademarks of SMC Networks, Inc. Other product and company names are trademarks or registered trademarks of their respective holders.
  • Page 5 All SMC products carry a standard 90-day limited warranty from the date of purchase from SMC or its Authorized Reseller. SMC may, at its own discretion, repair or replace any product not operating as warranted with a similar or functionally equivalent product, during the applicable warranty term.
  • Page 6 RIGHTS, WHICH MAY VARY FROM STATE TO STATE. NOTHING IN THIS WARRANTY SHALL BE TAKEN TO AFFECT YOUR STATUTORY RIGHTS. * SMC will provide warranty service for one year following discontinuance from the active SMC price list. Under the limited lifetime warranty, internal and external power supplies, fans, and cables are covered by a standard one-year warranty from date of purchase.
  • Page 7: Japan Vcci Class A

    OMPLIANCES FCC - Class A This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart B of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment.
  • Page 8 OMPLIANCES EC Conformance Declaration - Class A SMC contact for these products in Europe is: SMC Networks Europe, Edificio Conata II, Calle Fructuós Gelabert 6-8, 2 08970 - Sant Joan Despí, Barcelona, Spain. This information technology equipment complies with the requirements of the Council...
  • Page 9 OMPLIANCES Taiwan BSMI Class A Australia AS/NZS 3548 (1995) - Class A SMC contact for products in Australia is: SMC Communications Pty. Ltd. Suite 18, 12 Tryon Road, Lindfield NSW2070, Phone: 61-2-94160437 Fax: 61-2-94160474...
  • Page 10: Safety Compliance

    OMPLIANCES Safety Compliance Warning: Fiber Optic Port Safety When using a fiber optic port, never look at the transmit laser while CLASS I it is powered on. Also, never look directly at the fiber TX (transmit) LASER DEVICE port and fiber cable ends when they are powered on. Avertissment: Ports pour fibres optiques - sécurité...
  • Page 11 OMPLIANCES Wichtige Sicherheitshinweise (Germany) 1. Bitte lesen Sie diese Hinweise sorgfältig durch. 2. Heben Sie diese Anleitung für den späteren Gebrauch auf. 3. Vor jedem Reinigen ist das Gerät vom Stromnetz zu trennen. Verwenden Sie keine Flüssigoder Aerosolreiniger. Am besten eignet sich ein angefeuchtetes Tuch zur Reinigung.
  • Page 12 OMPLIANCES viii...
  • Page 13: Table Of Contents

    ABLE OF ONTENTS About the TigerStack 100 ..... . .1-1 Overview ..........1-1 Switch Architecture .
  • Page 14 ABLE OF ONTENTS Rack Mounting ........3-3 Desktop or Shelf Mounting .
  • Page 15 ABLE OF ONTENTS Standards ..........C-5 Compliances .
  • Page 16 ABLE OF ONTENTS...
  • Page 17: About The Tigerstack 100

    IGER TACK Overview SMC’s TigerStack™ 100 is a stackable switch with 24 100BASE-FX MT-RJ ports, plus two slots for optional slide-in 100BASE-FX or 1000BASE-X modules. One of these slots can also be used for an optional stacking module that allows you attach up to four switches to a 9.6 Gbps high-speed backplane.
  • Page 18: Switch Architecture

    BOUT THE IGER TACK 100BASE-FX Multimode Fiber Module 100BASE-FX Single-Mode Fiber Module 100Base-FX-SC Extender Module 100Base-FX-SC Singlemode Module SMC6900FSC SMC6900FSSC 1000BASE-SX Gigabit Module 1000BASE-LX Gigabit Module SMC6900G SMC6900GLSC 1000BASE-T Gigabit Module Stack Module SMC6900GT Figure 1-3. Optional Modules Switch Architecture The TigerStack employs a high-speed switching fabric.
  • Page 19: Management Options

    BOUT THE IGER TACK Management Options This switch contains a comprehensive array of LEDs for “at-a-glance” monitoring of network and port status. It also includes a Network Management Module that allows the entire stack to be managed in-band via SNMP or RMON (Groups 1, 2, 3 and 9) protocols, with a Web browser, or remotely via Telnet.
  • Page 20: Status Leds

    BOUT THE IGER TACK Status LEDs The LEDs, which are located on the front panel for easy viewing, are shown below and described in the following table. Status Activity Figure 1-4. Port and System LEDs Port and System Status LEDs Condition Status Power...
  • Page 21: Network Management Module

    BOUT THE IGER TACK Port and System Status LEDs Condition Status Module Ports A module is installed in this slot. Status Activity Traffic is passing through the module. Network Management Module Network Management Module SMC6924VFNMM RS-232 Figure 1-5. Network Management Module This switch includes a Network Management Module on the rear panel.
  • Page 22: Multicast Switching

    BOUT THE IGER TACK Some of this switch’s advanced features are described below. For a detailed description, refer to the Management Guide. Spanning Tree Protocol The TigerStack 100 supports IEEE 802.1D Spanning Tree Protocol. This protocol adds a level of fault tolerance by allowing two or more redundant connections to be created between a pair of LAN segments.
  • Page 23: Optional Media Extender Modules

    BOUT THE IGER TACK The switch uses IGMP Snooping and IGMP to manage multicast group registration. Traffic Priority This switch provides Quality of Service (QoS) by prioritizing each packet based on the required level of service, using two distinct categories with Weighted Fair Queuing.
  • Page 24 BOUT THE IGER TACK Using single-mode fiber (SMF) cable, the 100BASE-FX port can be connected to a remote site up to 10 km (6.21 mi.) away. This port operates only at 100 Mbps, full duplex. Optional 1000BASE-SX Module (SMC6900G) SMC6900G Figure 1-8.
  • Page 25: Optional Redundant Power Unit (Smcrpu150W)

    A stack cable is included with each module. Optional Redundant Power Unit (SMCRPU150W) SMC provides an optional Redundant Power Unit (RPU), SMCRPU150W, that can supply power to the switch in the event of failure of the internal power supply.
  • Page 26: Power Supply Receptacles

    BOUT THE IGER TACK Power Supply Receptacles There are two power receptacles on the rear panel of the switch. The standard power receptacle is for the AC power cord. The receptacle labeled “DC Input” is for the optional Redundant Power Unit (RPU). Figure 1-12.
  • Page 27: Features And Benefits

    BOUT THE IGER TACK Features and Benefits Connectivity N 24 multimode fiber MT-RJ ports that offer a cost-effective solution for fiber-to-the-desktop applications N Each MT-RJ port operates at 100 Mbps in half- or full-duplex mode (configured manually) N 62.5/125 micron and 50/125 micron multimode fiber cable supported on all MT-RJ ports N 802.3u Fast Ethernet compliance ensures compatibility with standards-based hubs, network cards and switches from any vendor...
  • Page 28: Performance

    BOUT THE IGER TACK N Optional 1000BASE-T Gigabit module that supports a connection of up to 100 meters using Category 5, 5e, or better cable, and operates at 1 Gbps, 100 Mbps, or 10 Mbps, half or full duplex, with auto-negotiation for speed, duplex mode and flow control N Optional Stack modules that can connect up to four switches (104 ports) to the stack’s 9.6 Gbps backplane...
  • Page 29 BOUT THE IGER TACK • Spanning Tree Protocol for redundant network connections • VLAN support for 256 groups, port-based or with IEEE 802.1Q VLAN tagging • Quality of Service (QoS) supports two levels of priority and Weighted Fair Queueing • Multicast Switching based on IGMP (Internet Group Management Protocol) Snooping and Multicast Filtering •...
  • Page 30 BOUT THE IGER TACK 1-14...
  • Page 31: Network Planning

    HAPTER ETWORK LANNING Introduction to Switching A network switch allows simultaneous transmission of multiple packets via non-crossbar switching. This means that it can partition a network more efficiently than bridges or routers. The switch has, therefore, been recognized as one of the most important building blocks for today’s networking technology.
  • Page 32: Sample Applications

    ETWORK LANNING Sample Applications The TigerStack 100 is not only designed to segment your network, but also to provide a wide range of options in setting up network connections. Some typical applications are described below. Collapsed Backbone The TigerStack 100 is an excellent choice for mixed Fast Ethernet installations where significant growth is expected in the near future.
  • Page 33: Central Wiring Closet

    ETWORK LANNING Central Wiring Closet With up to 104 ports in a stack (i.e., 104 distinct segments), the TigerStack 100 can collapse a complex network down into a single efficient bridged node, increasing overall bandwidth and throughput. In the figure below, the MT-RJ ports on the TigerStack stack are providing 100 Mbps connectivity for up to 96 end nodes.
  • Page 34: Remote Connections With Fiber Cable

    ETWORK LANNING Remote Connections with Fiber Cable Fiber optic technology allows for longer cabling than any other media type. A 100 Mbps multimode fiber (MMF) link can run up to 2 km (at full duplex), and a 100 Mbps single-mode fiber (SMF) link can run as far as 10 km.
  • Page 35: Making Vlan Connections

    ETWORK LANNING Making VLAN Connections VLANs can be based on port groups, or each data frame can be explicitly tagged to identify the VLAN group it belongs to. When using port-based VLANs, ports can either be assigned to any number of groups. Port-based VLANs are suitable for small networks.
  • Page 36: Connectivity Rules

    ETWORK LANNING Connectivity Rules When adding hubs (repeaters) to your network, please follow the connectivity rules listed below for Ethernet, Fast Ethernet, or Gigabit Ethernet. However, note that because switches break up the path for connected devices into separate collision domains, you should not include the switch or connected cabling in your calculations for cascade length involving other devices.
  • Page 37: 100 Mbps Fast Ethernet Collision Domain

    9/125 micron core single-mode fiber 10 km (6.21 miles) Single-Mode (SMF) - full duplex SMC 3-2 Rule for Class II Repeaters Between any two PCs or other stations in the same 100BASE-TX collision domain, there may be: • up to 3 link segments and •...
  • Page 38: Application Notes

    ETWORK LANNING Application Notes 1. Full-duplex operation only applies to point-to-point access (such as when a switch is attached to a workstation, server or another switch). When the switch is connected to a hub, both devices must operate in half-duplex mode. 2.
  • Page 39: Installing The Switch

    HAPTER NSTALLING THE WITCH Selecting a Site TigerStack 100 units can be mounted in a standard 19-inch equipment rack or on a flat surface. Be sure to follow the guidelines below when choosing a location. N The site should: • be at the center of all the devices you want to link and near a power outlet.
  • Page 40: Equipment Checklist

    N Power Cord—either US, Continental Europe or UK N RS-232 console cable N This Installation Guide N SMC Warranty Registration Card—be sure to complete and return to Optional Rack-Mounting Equipment If you plan to rack-mount the switch, be sure to have the following...
  • Page 41: Mounting

    NSTALLING THE WITCH Mounting A TigerStack 100 unit can be mounted in a standard 19-inch equipment rack or on a desktop or shelf. Mounting instructions for each type of site follow. Installing Optional Modules: Before mounting the switch, be sure you install any optional modules.
  • Page 42 NSTALLING THE WITCH To rack-mount devices: 1. Attach the brackets to the device using the screws provided in the Bracket Mounting Kit. S ta tu A c ti v it y Figure 3-1. Attaching the Brackets 2. Mount the device in the rack, using four rack-mounting screws (not provided).
  • Page 43: Desktop Or Shelf Mounting

    NSTALLING THE WITCH 3. If installing a single switch only, turn to “Connecting to a Power Source” at the end of this chapter. 4. If installing multiple switches, mount them in the rack, one below the other, in any order. 5.
  • Page 44: Installing An Optional Module Into The Switch

    NSTALLING THE WITCH Installing an Optional Module into the Switch Optional modules are available for media expansion, stacking and management. These modules can be installed into the modular slots on the rear panel of the switch. The Network Management Module must be installed in the upper slot, and the Stack Module in the lower-left slot.
  • Page 45: Stacking

    NSTALLING THE WITCH 1 0 0 B a s e - F X - S x t e n d e r M o d u l e S M C 6 9 0 0 F S Figure 3-4. Installing a Module 6.
  • Page 46 NSTALLING THE WITCH 4. Turn to the next section, “Connecting to a Power Source.” Figure 3-5. Stacking the Switches...
  • Page 47: Connecting To A Power Source

    NSTALLING THE WITCH Connecting to a Power Source To connect a device to a power source: Note: It is recommended that the switches be stacked before being connected to a power source. However, a device can be added to the top or bottom of a stack that is on and operating without first powering down the stack.
  • Page 48 NSTALLING THE WITCH 3. Check the front-panel LEDs as the device is powered on to be sure the Power LED is lit. If not, check that the power cable is correctly plugged in. The Mgmt LED on the unit with the Network Management Module installed will be lit.
  • Page 49: Making Network Connections

    HAPTER AKING ETWORK ONNECTIONS Connecting Network Devices The TigerStack 100 is designed to interconnect multiple segments (or collision domains). It may be connected to 100 Mbps network cards in PCs and servers, as well as to Fast Ethernet hubs, switches or routers. It may also be connected to remote devices using the optional 100BASE-FX or 1000BASE-X modules.
  • Page 50: Mt-Rj Fiber Connections

    AKING ETWORK ONNECTIONS MT-RJ Fiber Connections Each device requires a 62.5/125 micron or 50/125 micron multimode fiber optic cable with MT-RJ connectors at both ends. 1. Remove and keep the MT-RJ port’s plastic cover. When not connected to a fiber cable, the cover should be replaced to protect the optics. 2.
  • Page 51: Sc Fiber Connections

    SC connector at both ends. If you need to connect to a device with 62.5/125 micron cable that has ST-type connectors, SMC provides an optional SC-ST Converter (Part Number: 99-012034-091). Each single-mode fiber port requires 9/125 micron single-mode fiber optic cable with an SC connector at both ends.
  • Page 52 AKING ETWORK ONNECTIONS 3. Connect one end of the cable to the SC port on the switch and the other end to the SC port on the other device. Since SC connectors are keyed, the cable can be attached in only one orientation. Figure 4-1.
  • Page 53: 1000Base-T Twisted-Pair Connections

    AKING ETWORK ONNECTIONS 1000BASE-T Twisted-Pair Connections A 1000BASE-T connection requires a shielded or unshielded twisted-pair (STP or UTP) cable with RJ-45 connectors at both ends. For all connections, Category 5, 5e, or better (recommended) cable is required with all four wire pairs connected. You should also test the cable installation for IEEE 802.3ab compliance.
  • Page 54 AKING ETWORK ONNECTIONS Figure 4-2. Making Twisted-Pair Connections 2. If the device is a network card and the TigerStack is in the wiring closet, attach the other end of the cable segment to a modular wall outlet that is connected to the wiring closet (see “Wiring Closet Connections”...
  • Page 55: Wiring Closet Connections

    2. If not already in place, attach one end of a cable segment to the back of the patch panel where the punch-down block is located, and the other end to a modular wall outlet. 3. Label the cables to simplify future troubleshooting. Equipment Rack SMC TigerSwitch 100 (side view) Status Activity Punch-Down Block...
  • Page 56 AKING ETWORK ONNECTIONS...
  • Page 57: Troubleshooting

    The switch is either downloading firmware or running the Power-On Self-Diagnostics Test (POST). If this LED does not stop flashing, then POST has failed, and you should contact SMC Technical Support. Link LED is Off • Verify that the switch and attached device are powered •...
  • Page 58: Power And Cooling Problems

    If you still cannot isolate the problem, then the internal power supply may be defective. In this case, contact SMC Technical Support for assistance.
  • Page 59: Cables

    50/125 micron 400 MHz/km 2-500 m (7-1641 ft.) 500 MHz/km 2-550 m (7-1805 ft.) Note: If you need to connect to a device with 62.5/125 micron cable that has ST-type connectors, SMC provides an optional SC-ST Converter (Part Number: 99-012034-091).
  • Page 60: Rj-45 Port And Cable Assignments

    ABLES RJ-45 Port and Cable Assignments CAUTION: DO NOT plug a phone jack connector into any RJ-45 port. Use only twisted-pair cables with RJ-45 connectors that conform with FCC standards. The RJ-45 port on the SMC6900GT module supports 1000, 100, and 10 Mbps Ethernet operation, with auto-negotiation of speed, duplex mode, and flow control.
  • Page 61: Cable Testing For Existing Category 5 Cable

    ABLES The table below shows the 1000BASE-T MDI and MDI-X port pinouts. These ports require that all four pairs of wires be connected. Note that for 1000BASE-T operation, all four pairs of wires are used for both transmit and receive. MDI Signal Name MDI-X Signal Name Transmit Data plus (TD1+)
  • Page 62: Adjusting Existing Category 5 Cabling

    ABLES Additionally, cables must also pass test parameters for Return Loss and Equal-Level Far-End Crosstalk (ELFEXT). These tests are specified in the ANSI/TIA/EIA-TSB-95 Bulletin, “The Additional Transmission Performance Guidelines for 100 Ohm 4-Pair Category 5 Cabling.” Note that when testing your cable installation, be sure to include all patch cables between switches and end devices.
  • Page 63: Console Port Pin Assignments

    ABLES Console Port Pin Assignments The DB-9 serial port on the switch’s rear panel is used to connect to the switch for out-of-band console configuration. The on-board menu-driven configuration program can be accessed from a terminal or a PC running a terminal emulation program.
  • Page 64: Console Port To 25-Pin Dte Port On Pc

    ABLES Console Port to 25-Pin DTE Port on PC Switch’s 9-Pin Serial Null Modem PC’s 25-Pin DTE Port Port 2 RXD <---------RXD ------------ 2 TXD 3 TXD -----------TXD ----------> 3 RXD 5 SGND -----------SGND ---------- 7 SGND No other pins are used.
  • Page 65: Specifications

    PPENDIX PECIFICATIONS Physical Characteristics Ports 24 100BASE-FX fiber 1 slot for an optional media expansion module 1 slot for an optional media expansion module or stacking module Network Interface 100BASE-FX: MT-RJ connector Multimode fiber cable; 62.5/125 or 50/125 microns Stack Interface Connects up to 4 units 4.8 Gbps, full duplex, uplink/downlink ports 9.6 Gbps stack backplane bandwidth...
  • Page 66 PECIFICATIONS Weight 10.63 lbs (4.82 kg) Size 17.37 x 11.22 x 2.53 in (44.0 x 28.5 x 6.4 cm) Temperature ° ° Operating: 32 to 122 F (0 to 50 ° ° Storage: -40 to 158 F (-40 to 70 Humidity Operating: 5% to 95% AC Input...
  • Page 67: Switch Features

    PECIFICATIONS Switch Features Spanning Tree Protocol Forwarding Mode Store-and-forward Throughput Wire speed Flow Control Full Duplex: IEEE 802.3x Half Duplex: Back pressure Broadcast Storm Control Configurable threshold on a per-port basis. VLAN Support Up to 256 groups; port-based or with 802.1Q VLAN tagging Multicast Switching IGMP Snooping Quality of Service...
  • Page 68: Management Features

    TFTP or Web (HTTP) in-band or XModem out-of-band MIB Support MIB II (RFC 1213), Bridge MIB (RFC 1493), Ethernet-Like MIB (RFC 1643), RMON MIB (RFC 1757), SMC’s private MIB RMON Support Groups 1, 2, 3, 9 (Statistics, History, Alarm, Event)
  • Page 69: Standards

    PECIFICATIONS Standards IEEE 802.3u Fast Ethernet IEEE 802.3z, 802.3ab Gigabit Ethernet IEEE 802.1D Spanning Tree Protocol and traffic priorities IEEE 802.1Q VLAN Bridge Management IEEE 802.3x full-duplex flow control ISO/IEC 8802-3 SNMP (RFC 1157), RMON (RFC 1757), ARP (RFC 826), IGMP (RFC 1112), MIB II (RFC 1213), Interfaces Evolution MIB (RFC 1573), Ethernet-Like MIB (RFC 1643), Bridge MIB (RFC 1493) Compliances...
  • Page 70: Slide-In Module

    PECIFICATIONS Slide-in Module 100BASE-FX Extender Module Model SMC6900FSC, SMC6900FST, SMC6900FSSC Ports SMC6900FSC, SMC6900FST: 2 100BASE-FX multimode SMC6900FSSC: 1 100BASE-FX single-mode Network Interface SMC6900FSC, SMC6900FST: 50/125 or 62.5/125 micron multimode fiber cable (SMC6900FST includes SC-ST Converter) SMC6900FSSC: 9/125 micron single-mode fiber cable Communication Mode Full duplex Communication Rate...
  • Page 71: 1000Base-Lx Extender Module

    PECIFICATIONS Communication Mode Full and half duplex, auto-negotiation Communication Rate 1000 Mbps Standards IEEE 802.3z Gigabit Ethernet 1000BASE-LX Extender Module Model SMC6900GLSC Ports 1 1000BASE-LX Network Interface SC connector, 9/125 micron single-mode fiber cable Communication Mode Full and half duplex, auto-negotiation Communication Rate 1000 Mbps Standards...
  • Page 72: Agent Module

    PECIFICATIONS Communication Mode Full and half duplex, auto-negotiation Communication Rate 1000, 100, and 10 Mbps Standards IEEE 802.3ab Gigabit Ethernet Agent Module Model SMC6924MTNMM Ports 1 RS-232 serial port Connector Interface RS-232C DTE Standards IEEE 802.3u Fast Ethernet ISO/IEC 8802-3 Stack Module Model SMC6900S...
  • Page 73 PPENDIX RDERING NFORMATION TigerStack 100 Products and Accessories Product Number Description SMC6924MT 24-port MMF MT-RJ ports 100FX switch with two media expansion slots one RS-232 SMC6924MTNMM Network Management Module with serial port SMC6900S Stacking Module with 4.8 Gbps uplink/downlink ports SMC6900FSC Extender Module with two 100BASE-FX multimode fiber ports (SC-type Connector)
  • Page 74: Ordering Information

    RDERING NFORMATION...
  • Page 75: Glossary

    LOSSARY 10BASE-T IEEE 802.3 specification for 10 Mbps Ethernet over two pairs of Category 3, 4, or 5 UTP cable. 100BASE-FX IEEE 802.3u specification for 100 Mbps Fast Ethernet over two strands of 50/125 or 62.5/125 micron core fiber cable. 100BASE-TX IEEE 802.3u specification for 100 Mbps Fast Ethernet over two pairs of Category 5 UTP cable.
  • Page 76 LOSSARY Bandwidth The difference between the highest and lowest frequencies available for network signals. Also synonymous with wire speed, the actual speed of the data transmission along the cable. Class I Repeater Fast Ethernet repeater that is principally used to connect different physical signaling systems (e.g., 100BASE-TX, 100BASE-FX) and that has an internal delay such that only one repeater of this type can reside within a single collision domain when maximum cable lengths are used.
  • Page 77: Full Duplex

    LOSSARY Fast Ethernet A 100 Mbps network communication system based on Ethernet and the CSMA/CD access method. Fast Ethernet Switch Device that provides a full 100 Mbps bandwidth (or either 10 or 100 Mbps bandwidth with Auto-Negotiation) to each port (LAN segment). Full Duplex Transmission method that allows switch and network card to transmit and receive concurrently, effectively doubling the bandwidth of that link.
  • Page 78 LOSSARY IEEE 802.3u Defines CSMA/CD access method and physical layer specifications for Fast Ethernet. IEEE 802.3x Defines Ethernet frame start/stop requests and timers used for flow control on full-duplex links. IEEE 802.3z Defines CSMA/CD access method and physical layer specifications for 1000BASE Gigabit Ethernet.
  • Page 79: Network Diameter

    LOSSARY Media Access Control (MAC) A portion of the networking protocol that governs access to the transmission medium, facilitating the exchange of data between network nodes. An acronym for Management Information Base. It is a set of database objects that contains information about the device. Media Independent Interface, the standard interface for Fast Ethernet—similar to the AUI interface for traditional Ethernet.
  • Page 80 LOSSARY Transmission Control Protocol/Internet Protocol (TCP/IP) Protocol suite that includes TCP as the primary transport protocol, and IP as the network layer protocol. Unshielded twisted-pair cable. Virtual LAN (VLAN) A Virtual LAN is a collection of network nodes that share the same collision domain regardless of their physical location or connection point in the network.
  • Page 81: Index

    NDEX Numerics buffer size C-1 buffers, saturation of 1-3 100 Mbps connectivity rules 2-7 1000 Mbps connectivity rules 2-6 1000BASE-LX fiber cable lengths 2-6 cable module 1-8 lengths 2-6 1000BASE-SX specifications B-1 connections 4-3 cleaning fiber terminators 4-2 fiber cable lengths 2-6 compliances module 1-8 EMC C-5...
  • Page 82 NDEX fiber cables 4-3 LED indicators flow control, IEEE 802.3x 1-3 Activity 1-4 front panel of switch 1-1 FDX 1-4 full-duplex connectivity 2-1 Link 1-4 Mgmt 1-4 problems A-1 PWR 1-4 RDP 1-4 Gigabit Ethernet cable lengths 2-6 Status 1-5 grounding for racks 3-3 limited warranty C-5 location requirements 3-1...
  • Page 83 NDEX redundant power unit See RPU network RJ-45 port connections 4-5 connections 4-2 RJ-45 port pinouts B-3 examples 2-2 RMON 1-3 null-modem cable 1-5 routing applications 2-8 RPU 1-9 connecting 3-10 installing in a rack 3-5 installing on a desktop 3-5 optional RS-232 port 1-5 modules 1-2...
  • Page 84 NDEX tags priority 1-7 VLAN 2-5 Telnet A-2 temperature within a rack 3-3 traffic priority 1-7 troubleshooting in-band access A-2 power and cooling problems A-2 switch indicators A-1 VLANs 1-5 tagging 2-5 warranty C-5 Web-based management 1-3 Weighted Fair Queuing 1-7 Index-4...
  • Page 86 Fax 81-45-224-2331 Australia: 61-2-9416-0437; Fax 61-2-9416-0474 India: 91-22-8204437; Fax 91-22-8204443 If you are looking for further contact information, please visit www.smc.com or www.smc-europe.com. Model Number: SMC6924MT 38 Tesla Publication Number: 150200025600A Irvine, CA 92618 Revision Number: E092002-R01 Phone: (949) 679-8000...

This manual is also suitable for:

Tigerstack smc6924mt