SereneLife SLACHT128 User Manual
SereneLife SLACHT128 User Manual

SereneLife SLACHT128 User Manual

Portable air conditioner and heater
Hide thumbs Also See for SLACHT128:

Advertisement

Quick Links

Visit Our Website
SCAN ME
serenelifehome.com
SLACHT128
Portable Air Conditioner and Heater
USER MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLACHT128 and is the answer not in the manual?

Questions and answers

John Provenzano
April 15, 2025

Serenelife Schlact 128.. constant E4 code. Filters are clean, until turns on AC or humidifier and shuts off after 5 minutes. Eventually restarts by itself Positive the unit isnt frozen rather the temperature sensor is malfunctioning. Are you able to guide me as to how to identify it and can I order a replacement element.

1 comments:
Anthony
April 15, 2025

Positive the unit thinks it is frozen

Summary of Contents for SereneLife SLACHT128

  • Page 1 Visit Our Website SCAN ME serenelifehome.com SLACHT128 Portable Air Conditioner and Heater USER MANUAL...
  • Page 2: Table Of Contents

    PLEASE KEEP THIS MANUAL CAREFULLY FOR FUTURE REFERENCE. FOR HOUSEHOLD USE ONLY. CONTENT Features and Technical Speci cations Important Safety Tips Precautions Product Introduction Main Parts and Components Control Panel and Remote Controller Product Operation Placement and Installation Operation Method Clean and Maintenance Drainage Method Maintenance...
  • Page 3: Features And Technical Speci Cations

    Features: • Lightweight & Portable AC Unit • Compact Freestanding Room Air Conditioner & Heater • (4) Operation Modes: AC Cool / Heat / Dehumidi er / Fan • Hassle-Free, Quick Setup Heating & Cooling • Simple Electric Plug-in Operation •...
  • Page 4: Important Safety Tips

    Technical Specs: • AC Cooling Power: 12,000 BTU • Cooling Capacity (SACC): 7,800 BTU • Heating Power: 12,000 BTU • Coverage Area: Cools & Heats Rooms Up to 400’ + Square feet • Rated Power: 1035Watt • Air Flow: 360 Cubic Meters / Hour •...
  • Page 5 • The voltage of the A/C should meet the required speci cations. Any damage caused by incorrect power supply is not covered by the warranty. • Children are not allowed to play with the A/C. This appliance is not intended for use by children unless they have been given supervision or instruction concerning its use by a person responsible for their safety.
  • Page 6 REFRIGERANT (FOR R32 ONLY) CAUTION ON FIRE READ THE MANUAL CAREFULLY BEFORE USING THE APPLIANCE. R32 refrigerant gas complies with international environmental directives. Warnings • Do not use methods to accelerate the defrosting process or cleaning other than those recommended by the manufacturer. •...
  • Page 7 When using the product: • Keep any required ventilation openings clear of obstructions. • Servicing should be performed only as recommended by the manufacturer. Unventilated Area • An unventilated area where the appliance using ammable refrigerants is installed should be constructed so that, in case of a refrigerant leak, it will not stagnate and create a re or explosion hazard.
  • Page 8: Product Introduction

    Special Warning: • Place the A/C on even ground and install it vertically to ensure normal operation of the compressor. • Keep the A/C at least 50 cm (20 inches) away from surrounding objects. Ensure smooth air inlet and outlet. •...
  • Page 9 www.SereneLifeHome.com...
  • Page 10: Control Panel And Remote Controller

    Control Panel and Remote Controller 2,,(3 45'3 6&73 0)1+ 0%5< Cooling and Heating Model 1. Power Key: Press to turn ON/OFF the A/C. 2. Swing Key: Press to activate the automatic swinging of the wind guide bar. 3. Speed Key: Press to select high/medium/ low fan speed.
  • Page 11: Product Operation

    Product Operation Placement and Installation Placement: Place the unit on an even, dry surface, ensuring it is at least 50 cm (20 inches) away from surrounding objects. 50cm Installation: • Screw the exhaust duct assembly into the air outlet behind the panel (turn counterclockwise).
  • Page 12: Incorrect Installation

    Incorrect Installation: • It is important to keep the exhaust duct smooth. Incorrect installation will a ect the operation of the A/C. • Prevent the exhaust duct from sharp bending. • Ensure air can ow smoothly through the duct. Warning: The exhaust duct is speci cally designed for this model.
  • Page 13 Fan Mode: • When the mode key is pressed or Fan mode is selected via the remote controller, the wind indicator lamp will light up. • Press the Speed key to select high, medium, or low fan speed. • Temperature cannot be set in this mode. Dehumidi cation Mode: •...
  • Page 14: Clean And Maintenance

    Timer Mode: • In standby mode, press the Timer key to set the ON time. Use the Up and Down keys to set the ON time (1-24 hours). The timer indicator lamp will light up. • In ON mode, press the Timer key to set the OFF time. Use the Up and Down keys to set the OFF time (1-24 hours).
  • Page 15: Common Failures And Diagnosis

    Filter Screen • Vacuum the lter screen every two weeks. If it becomes blocked with dust, the e ciency of the A/C will be reduced. • Remove the air inlet grille and pull out the lter screen from both sides, as shown in the gures.
  • Page 16: Troubleshooting

    Troubleshooting In case of any of the following issues, please contact professional maintenance personnel immediately. Trouble Cause Solution Reset the circuit breaker on the No display A/C cord Restart the A/C after powering The A/C doesn’t work The display panel shows “FL” o and draining;...
  • Page 17: Register Product

    Register Product Start Here Thank you for choosing SereneLife. By registering your product, you ensure that you receive the full bene ts of our exclusive warranty and personalized customer support. Complete the form to access expert support and to keep your SereneLife purchase in perfect condition.
  • Page 18 Questions or Comments? We are here to help! Phone: 1.718.535.1800 Serenelifehome.com/ContactUs...