April 14, 2025

What is dry mode used for and do I have to dismantle air exhaust duct?

1 comments:
Mr. Anderson
April 15, 2025

The purpose of Dry Mode on the SereneLife SLPAC805W is to dehumidify the air. It operates the compressor when the ambient temperature is ≥17°C (62°F) and stops it when the temperature drops to ≤15°C (59°F).

It is not necessary to dismantle the air exhaust duct for Dry Mode. Instead, you need to remove the water plug and connect a drainage hose to allow water to drain into a tank or channel.

This answer is automatically generated

r.pursley@comcast.net
July 26, 2025

after short time unit shuts down and shows E5

Summary of Contents for SereneLife SLPAC805W

  • Page 1 SLPAC805W Portable Air Conditioner Compact Home A/C Cooling Unit with Built-in Dehumidifier & Fan Modes, Includes Window Mount Kit (8,000 BTU)
  • Page 2: Table Of Contents

    Read all instructions carefully before setting up and operating the unit. Please keep this instruction manual for future reference. This manual is designed to provide you with important information needed to setup, operate, maintain and troubleshoot your portable air conditioner. Failure to follow these instructions may damage and/or impair operation and void the warranty.
  • Page 3: User Tips

    USER TIPS Please avoid such operations, in case of any safety and health risks. Such instructions are to be followed, for safety and health concerns. PRECAUTIONS For indoor use only; For household use only please place the A/C in a dry environment.
  • Page 4 Do not operate the machine Please wipe the machine with a with wet hands or in a humid soft cloth, instead of wax, diluent environment. or irritant detergent. Clean the lter once every two For your health, never drink weeks condensed water discharged from the machine.
  • Page 5: Safety Warnings

    SAFETY WARNINGS Damaged power cord or plug Never damage the power cord, or shall not be used. Never plug use unlicensed power cord. Make to a loose socket. sure voltage is right. Do not modify or extend the A grounded outlet is suggested power cord.
  • Page 6 Never control on/o status by Please turn o the machine directly plugging/unplugging. before unplugging. Never overload the socket. Keep away from heat sources or direct sunlight exposure. If there is any actue noise, In case of electric shock, never smell or smoke, turn o and damage the power cord by unplug for diagnosis.
  • Page 7 Never insert ngers or any Keep electrical parts away from hard objects into the louver. water. If water enters, turn o and unplug Please turn o and unplug before in time; and call for check and wiping, cleaning or replacing repair from a professional.
  • Page 8: Tips

    TIPS For a proper work of compressor, For a proper ventilation, keep place the machine vertically on the machine at least 50cm from an even ground. objects nearby. Never use the appliance near Keep the appliance from spraying agent or any solvent, or plastics gasoline or other ammable objects.
  • Page 9: Product Overview

    PRODUCT OVERVIEW Main Components 1. Handle 2. Air Inlet Grille (Up) 3. Control Panel 4. Casters 5. Louver 6. Air Outlet Grille 7. Drainage Hole 8. Air Inlet Grille (Down) 9. Air Exhaust Duct Assembly 10. Window Sealing Kit www.SereneLifeHome.com...
  • Page 10: Control Panel And Remote Control

    CONTROL PANEL AND REMOTE CONTROL 1. Power Button Press the button for ON/OFF 2. Fan Speed Button Press the key to choose high/low speed 3. UP/Down Button for Temperature and Timer Under cooling mode, press the keys could increase or decrease setting temperature; In timer mode, press the keys to set time powering ON.
  • Page 11: Operation

    OPERATION Place & Install Best Install Place • Place the machine on the horizontal oor near the window. • For proper ventilation and best machine performance, keep the appliance at least 50cm from objects nearby. 50cm Install Air Exhaust Duct Assembly Connector Air exhaust duct Flat nozzle...
  • Page 12 Step 1: Clip- xture Type 1. Measure window size; 2. Adjust Length of the plate according to window size; 3. Lock the plate Step 2: Fix the plate to window Step 3: Swirl the exhaust pipe assembly (exhaust tting end) into the rear panel outlet (counterclockwise). www.SereneLifeHome.com...
  • Page 13 little breach screw 1.Plug in rst Step 4: Insert the exhaust pipe assembly (exhaust port end) into the window seal panel assembly and screw it up. Impression Drawing of Completion www.SereneLifeHome.com...
  • Page 14 Incorrect installation • It’s important to keep the exhaust duct smooth. Incorrect installation will a ect work of the A/C. • Prevent the exhaust duct from sharp bending. • Ensure air can ow smoothly in the duct. Warning The exhaust duct is designed especially for this model. Don’t replace or lengthen it; otherwise, it will result in failure.
  • Page 15: How To Operate

    Warning: 1. Never use leaked batteries; 2. Chemicals in batteries could result in such health hazards as burns. If liquid in batteries splashes to skin or clothes, please wash with clean water in time. If batteries are swallowed, please rinse mouth immediately with clean water and then go to the doctor.
  • Page 16: Clean And Maintenance

    TIMER MODE • In standby mode, press Timer button to set ON time. A range of 0 to 24 Hours could be set with UP/DOWN button. Timer indicator will light up in this mode. • Under running state, press Timer button to set OFF time. A range of 0 to 24Hours could be set with UP/DOWN button.
  • Page 17 Filter is to be cleaned once every two weeks. If air quality indoor is poor, it has to be washed more often, or performance of the appliance would be lowered due to blocked lter screen. Please follow below instructions for cleaning: Take o air-inlet grille as indicated in the photo;...
  • Page 18: Common Failures And Diagnosis

    Seasonal Maintenance If the appliance will not be in use for a long time, please maintain by following below steps: 1. Pull out water plug for drainage. 2. Run in Fan mode for at least 2 hours to dry internal parts. 3.
  • Page 19: Troubleshooting

    TROUBLESHOOTING The following table lists the common faults and maintenance methods of this series of portable A/C. When the machine is in abnormal operation, the following table can be used for simple diagnosis and maintenance. If it still can’t be solved, please contact professional maintenance personnel.
  • Page 20: Features And Technical Specs

    FEATURES: • Metal Control Box to Prevent from Fire and Exploding • Rotary Compressor • Universal Castors for Moving Freely • Wi function • Lightweight & Portable A/C Unit • Compact Freestanding Room Air Conditioner • (3) Operation Modes: AC Cooling / Dehumidi er / Fan •...
  • Page 21 TECHNICAL SPECS: • Power Supply: 115V/60Hz • Rated Power: 800W • Refrigerant Type: R410a • Cooling capacity (ASHRAE): 8,000 Btu/h • Cooling capacity (DOE): 5,000 Btu/h • Coverage Area: Cools Rooms up to 300 Square Feet • Air Flow: 360 Cubic Meters / Hour •...