Consort WMH3E Installation And Operating Manual

Quality space heaters
Hide thumbs Also See for WMH3E:

Advertisement

Quick Links

Q
S
H
I
O
M
C
N
:
WMH3E
I
O
M
All electrical appliances produced by the Company are guaranteed for one year against faulty
materials or workmanship.
This applies only if the appliance has been used for purposes in
accordance with the instructions provided and has not been connected to an unsuitable
electricity supply, or subject to misuse, neglect, damage or modified or repaired by any person
not authorised by us. This guarantee is offered to you as an extra benefit and does not affect your
legal rights.
The correct electricity supply voltage is shown on the rating label attached to the appliance.
Reasonable care has been taken to ensure that this guide is accurate at the time of printing.
In the interest of progress the Company reserve the right to vary specifications from time to time
without notice.
58000387 Iss 06
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WMH3E and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Consort WMH3E

  • Page 1 WMH3E All electrical appliances produced by the Company are guaranteed for one year against faulty materials or workmanship. This applies only if the appliance has been used for purposes in accordance with the instructions provided and has not been connected to an unsuitable electricity supply, or subject to misuse, neglect, damage or modified or repaired by any person not authorised by us.
  • Page 2: Table Of Contents

    Any modifications made to the unit not the correct working operation of the heater. DO approved by Consort will void manufac- NOT site this heater in a damp environment such as bathroom or drying rooms. DO NOT site the heater turer’s warranty and potentially create a...
  • Page 3: Dimensions

    2. Dimensions OPTIMUM MOUNTING HEIGHT IS 400mm FROM THE FLOOR. NOTE: - MINIMUM CLEARANCE FROM THE FLOOR IS 350mm. - MINIMUM CLEARANCE FROM THE SIDES OF THE HEATR AND ANY OPSTRUCTION IS 300mm. - THE HEATER MUST NOT BE LOCATED IMMEDIATELY BELOW A FIXED SOCKET OUTLET.
  • Page 4: Installation

    Drill 2 holes in the wall to suit No 10 wood screws (round head) and insert wall plugs. At The inlets of the WMH3E are all round the posterior the top 2 screw positions ‘A’ screws can now sides of the heater. While the outlet is on the front be screwed in until the heads are approxi- of the heater.
  • Page 5: Controls

    4.5 PROG - Automatic time mode tings will be saved. After 15 minutes, the WMH3E will return to the previous operating mode. In this mode, the heater will follow the week’s time / temperature program.
  • Page 6: Heat Symbol

    Setup 4.8 Setting the time and day menu). The WMH3E will come set with the correct time 4.10 Fan only mode and day. It has an internal battery back up that can remember the settings. It will auto- This appliance comes with a fan only option.
  • Page 7: Setting The Automatic Program Schedule

    5. Setting the automatic program schedule An example of one day program on WMH3E PROGRAM 1 PROGRAM 2 PROGRAM 5 PROGRAM 6 ºC PROGRAM PROGRAM 19ºC 22ºC 22ºC 16ºC 10ºC 4ºC 06:00 08:00 12:00 14:00 16:00 22:00 Step 4: Press the MENU button.
  • Page 8: Program Mode Overview

    6. Program mode overview 6.1 Overview of program mode from one day to another. The WMH3E has a 7-day, 5-day + 2-day and a To do this, follow the steps below; 24 hour timer available. This can be chosen in the Setup menu.
  • Page 9: Setup Menu

    7. Setup Menu Press and hold MENU and - together for 5 8 - Closed window detec- tion time seconds. The display will enter the setup menu. Use + and - to change a value. 9 - Temperature rise in Use Menu to scroll between the settings.
  • Page 10: Fault Detection And Indication

    8. Fault detection and indication 8.1 Self diagnostics 8.4 Maintenance This unit has a self diagnostic system in place to ALWAYS ENSURE THAT THE MAIN EXTERNAL ELEC- detect any faults with the heater, below is a table TRICITY SUPPLY IS SWITCHED OFF BEFORE COM- of all possible faults that will display on the screen MENCING ANY MAINTENANCE ON THIS HEATER.
  • Page 11: Wiring Diagrams

    9. Wiring diagrams...
  • Page 12: Declaration Of Conformity

    ETSI EN 300 220-2 V3.2.1 (2018-06) · · BS EN 60335.2.30 (2009) ETSI EN 301 489-1 V2.2.2 (2019) · · ETSI BS EN 303 645 ETSI EN 301 489-3 V2.1.1 (2019) · · WMH3E UMBER ESCRIPTION PPLIANCE O’S ESPONSIBLE ERSON AVID ULLIVAN OSITION PERATIONS MANAGER...

Table of Contents