Page 1
WMH3E All electrical appliances produced by the Company are guaranteed for one year against faulty materials or workmanship. This applies only if the appliance has been used for purposes in accordance with the instructions provided and has not been connected to an unsuitable electricity supply, or subject to misuse, neglect, damage or modified or repaired by any person not authorised by us.
Any modifications made to the unit not the correct working operation of the heater. DO approved by Consort will void manufac- NOT site this heater in a damp environment such as bathroom or drying rooms. DO NOT site the heater turer’s warranty and potentially create a...
2. Dimensions OPTIMUM MOUNTING HEIGHT IS 400mm FROM THE FLOOR. NOTE: - MINIMUM CLEARANCE FROM THE FLOOR IS 350mm. - MINIMUM CLEARANCE FROM THE SIDES OF THE HEATR AND ANY OPSTRUCTION IS 300mm. - THE HEATER MUST NOT BE LOCATED IMMEDIATELY BELOW A FIXED SOCKET OUTLET.
Drill 2 holes in the wall to suit No 10 wood screws (round head) and insert wall plugs. At The inlets of the WMH3E are all round the posterior the top 2 screw positions ‘A’ screws can now sides of the heater. While the outlet is on the front be screwed in until the heads are approxi- of the heater.
4.5 PROG - Automatic time mode tings will be saved. After 15 minutes, the WMH3E will return to the previous operating mode. In this mode, the heater will follow the week’s time / temperature program.
Setup 4.8 Setting the time and day menu). The WMH3E will come set with the correct time 4.10 Fan only mode and day. It has an internal battery back up that can remember the settings. It will auto- This appliance comes with a fan only option.
5. Setting the automatic program schedule An example of one day program on WMH3E PROGRAM 1 PROGRAM 2 PROGRAM 5 PROGRAM 6 ºC PROGRAM PROGRAM 19ºC 22ºC 22ºC 16ºC 10ºC 4ºC 06:00 08:00 12:00 14:00 16:00 22:00 Step 4: Press the MENU button.
6. Program mode overview 6.1 Overview of program mode from one day to another. The WMH3E has a 7-day, 5-day + 2-day and a To do this, follow the steps below; 24 hour timer available. This can be chosen in the Setup menu.
7. Setup Menu Press and hold MENU and - together for 5 8 - Closed window detec- tion time seconds. The display will enter the setup menu. Use + and - to change a value. 9 - Temperature rise in Use Menu to scroll between the settings.
8. Fault detection and indication 8.1 Self diagnostics 8.4 Maintenance This unit has a self diagnostic system in place to ALWAYS ENSURE THAT THE MAIN EXTERNAL ELEC- detect any faults with the heater, below is a table TRICITY SUPPLY IS SWITCHED OFF BEFORE COM- of all possible faults that will display on the screen MENCING ANY MAINTENANCE ON THIS HEATER.
ETSI EN 300 220-2 V3.2.1 (2018-06) · · BS EN 60335.2.30 (2009) ETSI EN 301 489-1 V2.2.2 (2019) · · ETSI BS EN 303 645 ETSI EN 301 489-3 V2.1.1 (2019) · · WMH3E UMBER ESCRIPTION PPLIANCE O’S ESPONSIBLE ERSON AVID ULLIVAN OSITION PERATIONS MANAGER...
Need help?
Do you have a question about the WMH3E and is the answer not in the manual?