Summary of Contents for Stryker SmartPump 5920-011-000
Page 1
5.5 inch (width) x 8.5 inch Black Graphics on White Background; document should not appear Booklet 20# Bond or Equivalent Description/Type: on produced Labels or IFUs. Instructions For Use Stryker Instruments Print Location: Suppliers/Services: Part Number: Rev. (269) 323-7700 (800) 253-3210 Print Center 5920-011-700 DSGN-fm-50366 rev.
Page 2
® SmartPump Tourniquet System Dual Channel Tourniquet Pump 5920-011-000 Instructions For Use Software Version 1.xx ENGLISH (EN) 2013-03 5920-011-700 Rev-F www.stryker.com...
Page 4
5920-011-700 Rev-F Important Information Contraindications The words WARNING, CAUTION and NOTE have The Stryker SmartPump Tourniquet System special meaning and should be reviewed. is not intended to be used as a ligature or in lieu of cauterization to stop hemorrhages.
Page 5
NOTE: If you need more information or in-service training, contact your Stryker sales representative or call Stryker customer service at 1-800-253-3210. Outside the US, contact your nearest Stryker subsidiary.
Page 6
DESCRIPTION Rolling Stand 5920-013-000 Tubing, Stockinettes, 5920-XXX-XXX series Fill Lines, and Adapters Disposable Cuffs 5921-XXX-XXX series Reusable Cuffs 5922-XXX-XXX series Report Printer Kit 5920-012-000 NOTE: Contact your Stryker sales representative for a complete list of additional accessories. www.stryker.com...
Page 7
Press and hold for 1.5 seconds to allow the adjustment of the TIME or deflate the cuff of the selected channel. PRESSURE values for the selected cuff channel. After adjustments have been made, press the button again to save the new values. www.stryker.com...
Page 8
Turn to install, adjust height, and remove PRINT Port the pump from the rolling stand. Using a serial cable, allows the connection of a Stryker Tourniquet Report Printer to the pump. ALARM MUTE Indicator/Button Illuminates green to indicate normal operation and flashes red to indicate an alarm condition.
Page 9
Displays the real-time, actual pressure Displays the IVRA lock or unlock status value of an inflated cuff in millimeters [shown unlocked]. of mercury and a graphical pressure Battery Status Area gauge icon. Displays the charge status or power level of the internal battery. www.stryker.com...
Page 10
Over Pressure Gauge The actual pressure value of the selected cuff is greater than the set target pressure value. IVRA Lock The Intravenous Regional Anesthesia (IVRA) control is locked. IVRA Unlock The IVRA control is unlocked. www.stryker.com...
Page 11
Indicates the cuff pressure value is either high or low Six beeps, about one beep per Indicates the cuff time value has second, followed by a six second exceeded its limit pause (silent), then repeated www.stryker.com...
Page 12
Time Control Pressure Adjustment Control (Stand-by) Adjustment Set and Inflate Deflate Cuff One Cuff Two Fill Line Default Save Connector Connector Connection Display Only Cuff One Cuff Two Print Report Printer Port IVRA Lock/ Increase Decrease Channel Channel UnLock Control www.stryker.com...
Page 13
ON the pump. An audible tone will occur to indicate power is applied. See 2. Press the SET/SAVE button to save the new the Audible Event Indicators section. value. Observe the minute value is blinking. www.stryker.com...
Page 14
1. Press the TIME INCREASE or DECREASE buttons of cuff channel one to set the month value. 2. Press SET/SAVE button to save the new value. Observe the day value is blinking. Figure 2 To Initiate Setting the Values www.stryker.com...
Page 15
NOTE: The time display format cannot be changed during an active cuff procedure. 3. Press the INCREASE button on the TIME control of both cuff channels simultaneously. 4. Observe the current time format on the information screen change automatically, for example, from H:MM to MINUTES. www.stryker.com...
Page 16
NOTE: The alarm volume may be adjusted in the one and two. Both channel display setting active or READY mode. values will blink to confirm de-selection of the minimization mode. Figure 6 To Minimize the Display of Screen Values Figure 5 To Adjust Alarm Value www.stryker.com...
Page 17
The pump will not deflate the cuff automatically when the target time is reached. You must press the DEFLATE button to deflate the selected cuff. www.stryker.com...
Page 18
To Change the Procedure Time and Target Pressure Values NOTES: Time and pressure values may be changed when the pump is in the READY mode or during active cuff inflation. www.stryker.com...
Page 19
Bier Block procedure or death. the management of two cuffs involved in a bilateral procedure. See the To Perform a Bier Block Procedure section for details. www.stryker.com...
Page 20
See the To Change the Procedure Time and Target Pressure Values section. After incremental deflation of the cuff is complete, press the IVRA LOCK/ UNLOCK CONTROL button to unlock the control and allow full deflation of the cuff. www.stryker.com...
Page 21
DO NOT service this equipment. If you abrasive, hospital enzymatic cleaning require service, contact your Stryker sales solution. representative or call Stryker customer 2. Wipe the external surfaces of the equipment service at 1-800-253-3210.
Page 22
Audible tone occurs, using the internal battery tone for 60 seconds. ALARM MUTE indicator/button power. Connect AC power to the blinks red, and the battery pump as soon as possible to charge icon has no band charge the internal battery. segments. www.stryker.com...
Page 23
20 mmHg above the obstructed. target value for more than If the condition persists, return five seconds while the cuff is the pump for repair. deflated or in a ready state. www.stryker.com...
Page 24
The system has detected an Return the pump for repair. information screen. hardware error condition. CODE 38 appears on the The system has detected Return the pump for repair. information screen. a power supply or battery charging error condition. www.stryker.com...
Page 25
DO NOT dispose of as unsorted municipal waste. Contact local distributor for disposal information. To comply with Batteries Directive 2006/66/EC, this device has been designed for safe removal of the batteries at end-of-life by a waste treatment facility. www.stryker.com...
Page 26
Real-time digital numeric with graphic pressure gauge Accuracy: ± 2% or 4 mmHg, whichever is greater, set pressure value Range: 100 to 475 mmHg NOTE: Specifications are approximate and may vary from unit to unit or as a result of power supply fluctuations. www.stryker.com...
Page 27
5920-011-000 is suitable for use in all establishments CISPR 11 other than domestic establishments and those directly Harmonic emissions Class A connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. IEC 61000-3-2 Voltage fluctuations/ Complies flicker emissions IEC 61000-3-3 www.stryker.com...
Page 28
NOTE 1: At 80 MHz and 800 MHz the higher frequency range applies. NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. www.stryker.com...
Page 29
(50/60 Hz) at 50/60 Hz should be at levels magnetic field characteristics of a typical location in a typical commercial or IEC 61000-4-8 hospital environment. NOTE: U is the alternating current mains voltage prior to application of the test level. www.stryker.com...
Page 30
NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. www.stryker.com...
Page 31
Channel Tourniquet Pump contains software that is installed by Stryker Corporation (“Stryker”). Elapsed Procedure 1 hour [1:00 Stryker owns this software and is licensing it to Time Value displayed] you, the original pump customer, subject to the Target Cuff Pressure 250 mm Hg [250 following terms and conditions.
Page 33
ES/DE/FR/IT/NL 5920-011-712 JA/ZH/KO 5920-011-720 SV/DA/FI/PT/NO 5920-011-730 PL/EL 5920-011-750 Stryker Instruments 4100 E. Milham Kalamazoo, Michigan (USA) 49001 1-269-323-7700 1-800-253-3210 Stryker France ZAC Satolas Green Pusignan Av. de Satolas Green 69881 MEYZIEU Cedex France 2013-03 5920-011-700 Rev-F www.stryker.com...