Page 1
MODEL: S3224IB-XX Version: 1.1 INSTALLATION GUIDE WALL MOUNT SHOWER SYSTEM MODEL FINISH S3224IB-CH CHROME S3224IB-BN BRUSHED NICKEL S3224IB-BG BRUSHED GOLD S3224IB-MB MATTE BLACK S3224IB-MG MATTE BLACK & BRUSHED GOLD HOT LINE: +1-866-203-0866...
Page 2
THANK YOU Dear Valued Customer, Thank you for choosing SUMERAIN products. We would like to take this opportunity to express our sincere gratitude for your recent purchase. We hope you are completely satisfied with your new product. Rest assured, we meticulously engineer all SUMERAIN products and put them through rigorous factory tests to ensure their prolonged, trouble-free use under normal conditions.
Page 3
("SUMERAIN"). This warranty applies solely to SUMERAIN products purchased by consumers in the United States after January 1st , 2020. In the event of a faucet experiencing leaks or drips during regular usage, SUMERAIN will provide the necessary faucet cartridge to the pur chaser, free of charge, in order to restore the faucet to proper working condition.
Page 4
FUNCTIONS & SPECIFICATIONS Faucet Type Shower System Feature Concealed Shower Faucet Theme Modern, Contemporary Mounting Type Wall Mount Finish Chrome, Brushed Nickel, Matte Black, Brushed Gold, Matte Black & Brushed Gold Number Of Handles Handles Material Metal Handle Style Lever Shower Arm Reach 15-3/4Inch [400mm ] Showerhead Width...
Page 6
NPT 1/2" Finish wall NPT 1/2" NPT 1/2" NPT 1/2" Ground SIDE VIEW OF SHOWER...
Page 7
ASSEMBLE PHH32231XX Red/Blue Button PSA00004XX Wall Supply Elbow ASSEMBLE PHH32230XX Set Screw SUS304 PSC05051XX Mounting Screw SUS304 PSC00002XX Diverter Knob Zn Alloy No.3 PHD00004XX If any of these items are missing, please contact SUMERAIN consumer service by email to: supports@sumerain.com.
Page 8
4. PLANNING AND INSTALLATION INSTRUCTIONS Attentions: The shower has to be installed, rinsed and checked in compliance with the applicable regulations in order to guarantee proper shower function! The dimensions of the shower set-up must be individually. Operating pressure at the control valve: Max.
Page 9
5.2 Turn on your shut-off valve for cleaning the hot and cold water supply pipe before connect to the valve body, allow the water flush 3~5 minutes to flush out dirt and debris. Shut off the water supply again after finish. HOT WATER SUPPLY COLD WATER SUPPLY 5.3 Locate and level the valve assembly with air level.
Page 10
5.4 Connect the valve body to the water supply system using the appropriate fittings for your valve type (copper, iron, or PEX). Note: For PEX, be sure to use the correct crimp fittings and proper cold expansion tool. We take copper tubing as example: 5.4.1(a) Remove the cartridge and check-in valve and pressure reducing valve from valve body before soldering.
Page 12
5.4.4 Locate and level the valve assembly and secure to the mounting bracket with screws and anchors. Please align the elbow front face with the finish wall. Improper elbow installation depth will lead to leak from connector or has to customize extension parts with extra expense.
Page 13
5.4.5 Please skip steps 5.4.1(a) to 5.4.4(a) if connect with PEX fittings or PVC fittings. The valve doesn’t need to be disassembled. Apply Teflon tape to the threads of valve body and connect to supply pipes and shower pipe with PEX fittings. [Left for hot water, right for cold water].
Page 14
6. VALVE TRIM INSTALLATION 6.1 Remove the plaster guard covers and check all connection for leaks. 6.2 Pressure testing & flushing the installation. Use appropriate fittings to plug the outlets and check for leaks. After testing, remove the shower plug and flush the system again. Reinstall the plaster guard covers after flushing.
Page 16
6.3 Done the finish wall and drill proper window for maintain if needs in the future. 6.4 Take off the bonnet cap, bonnet nut and the temperature limit ring from the valve assembly. 6.5 Turn on and adjust the cartridge to achieve the desired shower water maximum temperature. Anti-scald protection: It is important to regularly test the mixing valve to prevent scalding risks and ensure user safety.
Page 17
6.6 Attach the temperature limit ring to cartridge for locking the maximum temperature. Reinstall the bonnet cap and bonnet nut to the bonnet too. 6.7 Attach the escutcheon over the valve body. 6.8 Seal the wall around the escutcheon with waterproof sealant.
Page 18
6.9 Attach handle onto the valve stem and tighten set screws by the Allen wrench that is provided. Please don’t over tighten. Finally press-in the screw cover. 6.10 Valve trim installation finished. 7. SHOWERHEAD INSTALLATION 7.1 Attach shower arm escutcheon to the shower arm and apply Teflon tape to the thread of shower arm. Then secure the shower arm into the pipe elbow inside the wall by rotating clockwise.
Page 19
7.2 Seal the wall around the shower arm escutcheon with waterproof sealant. 7.3 Put the screen washer into the connector of showerhead and secure the showerhead on the shower head arm by hand rotating clockwise. Missing the screen washer might lead to shower invalid.
Page 20
8. HAND SHOWER INSTALLATION 8.1 Apply Teflon tape to the thread of wall supply elbow and screw the thread into the pipe elbow inside the wall. 8.2 Attach the docking of hand shower holder to the wall and fasten by mounting screws.
Page 21
8.3 Docking the hand shower holder to the dock and secure with set screw by Allen wrench. 8.4. Connect the hand shower to the wall supply elbow with flexible hose.
Page 22
9. INSPECTION 9.1 Turn on hot and cold water supply and check all connection for ensuring no leaking anywhere. 10. FUNCTION INSPECTION 10.1 Turn on the handle, the water outflow from the showerhead. 10.2 Switch the diverter knob, the water will outflow from the hand shower. INSTALLATION FINISHED...
Page 23
Address: 1226 NORTH KING ST NUM 522 WILMINGTON, DE 19801 United States Tel: +1(866)203-0866 Web: http://www.sumerain.com E-mail: supports@sumerain.us HONGKONG SUMERAIN SANITARY INDUSTRY CO., LIMITED Address: FLAT/RM 3B 3/F BANK TOWER NOS.351&353 KING'S ROAD NORTH POINT Tel: +86-750-2731579 E-mail: supports@sumerain.com SUMERAIN EUROPE SUPPORT Flottwellstr.