7.2. GENERAL CHARACTERISTICS
Reference guidelines
Safety:
EMC :
Insulation :
Pollution degree:
Measurement category:
Display
Characteristics:
Sample rate:
Conversion mode:
Power supply
Battery type:
Indicazione batteria scarica:
Battery life:
Auto Power Off:
Mechanical characteristics
Dimensions (L x W x H):
Weight (including battery):
Max conductor size:
Mechanical protection:
Environmental conditions
Reference temperature:
Operating temperature:
Operating humidity:
Storage temperature:
Storage humidity:
Max height of use:
This product conforms to the prescriptions of the European directive on
low voltage 2014/35/EU and to EMC directive 2014/30/EU
This instrument satisfies the requirements of 2011/65/EU (RoHS)
directive and 2012/19/EU (WEEE) directive)
7.3. ACCESSORIES
7.3.1. Standard accessories
•
Couple of test leads
•
Carrying bag
•
Battery
•
User manual
38
IEC/EN61010-1
IEC/EN61326-1
double insulation
2
CAT III 600V to ground
3½ LCD (2000counts), decimal point
unit symbol, and backlight
2 times/sec
Mean value
1 battery 9V IEC 6F22
"BAT "is displayed
about 150 hours (backlight OFF)
about 50 hours (backlight ON)
after 15 minutes of idleness
197 x 70 x 40mm ; 8 x 3 x 2 in
183g (6 ounces)
30mm (1in)
IP40
23°C ± 5°C (73°F ± 41°F)
5°C ÷ 40°C (41°F ÷ 104°F)
<80%RH
-20°C ÷ 60 °C (-4°F ÷ 140°F)
<80%RH
2000m (6.562ft)
HT4010