Download Print this page
Mitsubishi Electric 800 Series Instruction Manual
Mitsubishi Electric 800 Series Instruction Manual

Mitsubishi Electric 800 Series Instruction Manual

Ul type 1
Hide thumbs Also See for 800 Series:

Advertisement

Quick Links

INVERTER
A800/F800
INSTRUCTION MANUAL
(UL TYPE 1 SPECIFICATIONS)
FR-A820-00046(0.4K)-01250(22K)-N6
FR-A840-00023(0.4K)-00620(22K)-N6
FR-F820-00046(0.75K)-01250(30K)-N6
FR-F840-00023(0.75K)-00620(30K)-N6
Thank you for choosing this Mitsubishi Electric inverter.
This Instruction Manual provides handling information and precautions that are specific to the FR-A800/F800-N6
series, which is the dedicated model with the UL Type 1 specifications. The common information can be found in
the Instruction Manual of the FR-A800/F800 series.
In addition to this manual, carefully read the Instruction Manual (Startup), the Instruction Manual (Detailed), and
the Safety Stop Function Instruction Manual. Do not use this product until you have a full knowledge of the
equipment, safety information and instructions.
Please forward this Instruction Manual to the end user.
1
INVERTER INSTALLATION .......................................................................................... 4
2
OUTLINE DIMENSION DRAWINGS.............................................................................. 5
3
WIRING COVER AND HANDLING ................................................................................ 7
4
RATING .......................................................................................................................... 9
─CONTENTS─
800
800

Advertisement

loading
Need help?

Need help?

Do you have a question about the 800 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Mitsubishi Electric 800 Series

  • Page 1 FR-F820-00046(0.75K)-01250(30K)-N6 FR-F840-00023(0.75K)-00620(30K)-N6 Thank you for choosing this Mitsubishi Electric inverter. This Instruction Manual provides handling information and precautions that are specific to the FR-A800/F800-N6 series, which is the dedicated model with the UL Type 1 specifications. The common information can be found in the Instruction Manual of the FR-A800/F800 series.
  • Page 2 Such training may be available at your  Be sure to perform daily and periodic inspections as specified in the local Mitsubishi Electric office. Contact your local sales office Instruction Manual. If a product is used without any inspection, a burst, breakage, or a fire may occur.
  • Page 3 Application of caution labels  For the FR-A800-N6 series, performing pre-excitation (LX signal and X13 Caution labels are used to ensure safety during use of Mitsubishi Electric signal) under torque control (Real sensorless vector control) may start the inverters.
  • Page 4 INVERTER INSTALLATION  Inverter model FR - A8 0 00046 Symbol Voltage class Symbol Description Symbol Type∗1 Plated UL Type 1 Symbol Circuit board coating∗3 conductor certification 00023 to 01250 SLD rated inverter current (A) 200V class 0.4 to 22K ND rated inverter capacity(kW) Without 400V class...
  • Page 5 OUTLINE DIMENSION DRAWINGS FR-A820-00046(0.4K), 00077(0.75K)-N6, FR-F820-00046(0.75K), 00077(1.5K)-N6 2-φ6 hole 6 (0.24) 7.5 (0.3) 95 (3.74) 4-φ28 hole 110 (4.33) (With a knockout hole) 32.5 32.5 (1.28) (1.77) (1.28) Inverter Model FR-A820-00046(0.4K)-N6 111.6 (4.39) 21.6 (0.85) FR-F820-00046(0.75K)-N6 FR-A820-00077(0.75K)-N6 126.6 (4.98) 36.6 (1.44) FR-F820-00077(1.5K)-N6 (Unit: mm (inches)) FR-A820-00105(1.5K), 00167(2.2K), 00250(3.7K)-N6...
  • Page 6 FR-A820-00340(5.5K), 00490(7.5K), 00630(11K)-N6 FR-A840-00170(5.5K), 00250(7.5K), 00310(11K), 00380(15K)-N6 FR-F820-00340(7.5K), 00490(11K), 00630(15K)-N6 FR-F840-00170(7.5K), 00250(11K), 00310(15K), 00380(18.5K)-N6 2-φ6 hole 6 (0.24) 12.5 (0.49) 195 (7.68) 220 (8.66) (1.77) (2.56) (2.56) (1.77) 3-φ44 hole Inverter Model (With a knockout hole) FR-A820-00340(5.5K), 00490(7.5K)-N6 FR-A840-00170(5.5K), 00250(7.5K)-N6 126.8 FR-F820-00340(7.5K), 00490(11K)-N6 (12.76)
  • Page 7 WIRING COVER AND HANDLING  Removal of the wiring cover Remove the inverter front cover. (For the details on how to remove the front cover, refer to the Instruction Manual (Detailed) of the A800/F800 series.) Loosen the fixing screws, and remove the front lid of the wiring cover. FR-A820-00630(11K)-N6, FR-F820-00630(15K)-N6 Fixing screws Loosen the fixing screws that fix the wiring cover to the inverter, and remove the wiring cover.
  • Page 8  Removing the knockout holes Punch out the knockout holes by firmly tapping it with an object, such as a hammer. Remove any sharp edges and burrs from knockout holes of the wiring cover. FR-A820-00630(11K)-N6, FR-F820-00630(15K)-N6 Conduit hubs must always be used to connect conduit to the enclosure knockout. The hub shall be assembled to the conduit before it is installed in the conduit box knockout opening.
  • Page 9 RATING  FR-A800-N6 series 200 V class 00046 00077 00105 00167 00250 00340 00490 00630 00770 00930 01250 Model FR-A820-[]-N6 (0.4K) (0.75K) (1.5K) (2.2K) (3.7K) (5.5K) (7.5K) (11K) (15K) (18.5K) (22K) 0.75 18.5 0.75 18.5 Applicable motor capacity (kW)  ND (initial setting) 0.75 18.5...
  • Page 10  FR-A800-N6 series 400 V class 00023 00038 00052 00083 00126 00170 00250 00310 00380 00470 00620 Model FR-A840-[]-N6 (0.4K) (0.75K) (1.5K) (2.2K) (3.7K) (5.5K) (7.5K) (11K) (15K) (18.5K) (22K) 0.75 18.5 0.75 18.5 Applicable motor capacity (kW)  ND (initial setting) 0.75 18.5 0.75...
  • Page 11  FR-F800-N6 series 200 V class 00046 00077 00105 00167 00250 00340 00490 00630 00770 00930 01250 Model FR-F820-[]-N6 (0.75K) (1.5K) (2.2K) (3.7K) (5.5K) (7.5K) (11K) (15K) (18.5K) (22K) (30K) 0.75 18.5 Applicable motor capacity (kW)  0.75 18.5 Rated capacity (kVA) ...
  • Page 12  FR-F800-N6 series 400 V class 00023 00038 00052 00083 00126 00170 00250 00310 00380 00470 00620 Model FR-F840-[]-N6 (0.75K) (1.5K) (2.2K) (3.7K) (5.5K) (7.5K) (11K) (15K) (18.5K) (22K) (30K) 0.75 18.5 Applicable motor capacity (kW)  0.75 18.5 Rated capacity (kVA) ...
  • Page 13 Manufacturer Rated Voltage, Vac MMP-T32 Mitsubishi Electric Corp. 480Y / 277  Suitable for Use in a Circuit Capable of Delivering Not More Than 50 or 25 kA rms Symmetrical Amperes, 480Y/277 Volts Maximum when protected by the Type E Combination motor Controllers indicated in the above table.
  • Page 14  Motor overload protection (FR-A800-N6 series) When using the electronic thermal relay function as motor overload protection, set the rated motor current in Pr.9 Electronic thermal O/L relay. Operation characteristics of electronic thermal relay function This function detects the overload (overheat) of the motor, stops the operation of the inverter's output transistor, and stops the output.
  • Page 15 Instruction Manual (Startup) et Instruction Manual (Detailed)) destinés à être utilisés avec ce produit. Veuillez transmettre les manuels correspondants à l’utilisateur final. Les manuels peuvent également être téléchargés au format PDF sur Mitsubishi Electric FA Global Website. Pour commander des manuels, veuillez contacter votre représentant commercial.
  • Page 16 (When Pr.9 setting is 0(A)) percentage to the rated motor current.  When you set the electronic thermal relay function dedicated to the Mitsubishi Electric constant-torque motor, this characteristic curve applies to operation at 6 Hz or higher. ...
  • Page 17 MEMO...
  • Page 18 MEMO...
  • Page 19 REVISIONS *The manual number is given on the bottom left of the back cover. Print Date *Manual Number Revision Oct. 2013 IB(NA)-0600529ENG-A First edition Jul. 2014 IB(NA)-0600529ENG-B Added • Compatibility with the FR-F800-N6 series May 2015 IB(NA)-0600529ENG-C Edited • Location change of earth (ground) terminals (FR-A820-00105(1.5K) to 00250(3.7K)-N6, FR-A840- 00023(0.4K) to 00126(3.7K)-N6, FR-F820-00105(2.2K) to 00250(5.5K)-N6, FR-F840-00023(0.75K) to 00126(5.5K)-N6) Oct.
  • Page 20 GR-18542 Piraeus SE- 223 55 Lund Phone: +30 (0)211 / 1206-900 Phone: +46 (0) 8 625 10 00 Fax: +30 (0)211 / 1206-999 Mitsubishi Electric Turkey Elektrik Ürünleri A.Ş. TURKEY MELTRADE Kft. HUNGARY Fabrika Otomasyonu Merkezi Fertő utca 14. Şerifali Mahallesi Nutuk Sokak No.5 HU-1107 Budapest TR-34775 Ümraniye-İSTANBUL...

This manual is also suitable for:

Fr-a800 seriesFr-f800 seriesFr-a820-00046-n6Fr-a820-00077-n6Fr-f820-00046-n6Fr-f820-00077-n6 ... Show all