Chapter 2 Hardware Installation and Connection

Figure 5 Attaching Rubber Feet

Do NOT block the ventilation holes. Leave space between devices when
stacking.

2.3 Mounting the Switch on a Rack

The Switch can be mounted on an EIA standard size, 19-inch rack or in a wiring closet with
other equipment. Follow the steps below to mount your Switch on a standard EIA rack using a
rack-mounting kit.

2.3.1 Rack-mounted Installation Requirements

• Two mounting brackets.
• Eight M3 flat head screws and a #2 Philips screwdriver.
• Four M5 flat head screws and a #2 Philips screwdriver.
Failure to use the proper screws may damage the unit.
2.3.1.1 Precautions
• Make sure the rack will safely support the combined weight of all the equipment it
contains.
• Make sure the position of the Switch does not make the rack unstable or top-heavy. Take
all necessary precautions to anchor the rack securely before installing the unit.

2.3.2 Attaching the Mounting Brackets to the Switch

1 Position a mounting bracket on one side of the Switch, lining up the four screw holes on
the bracket with the screw holes on the side of the Switch.