PROPANE GAS MODELS:
SAFETY INFORMATION
WARNING
!
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
- Do not store or use gasoline or other
fl ammable vapors and liquids in the vicinity of
this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
f i r e - p a r t s . c o m
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call
the fi re department.
- Installation and service must be performed
by a qualifi ed installer, service agency, or the
supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless
a certifi ed kit is used.
INSTALLER:
Leave this manual with the appliance
CONSUMER:
Retain this manual for future reference
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030
Phone 1 (866) 820-8686 • www.continentalfi replaces.com • hearth@continentalfi replaces.com
$10.00
CB42NTR / CB42NTRE
ADD PRODUCT CODE HERE (TRADE GOTHIC LT STD FONT)
CB42PTR / CB42PTRE
INSTALLATION AND
ADD MANUAL TITLE
OPERATION MANUAL
CERTIFIED TO THE CANADIAN AND AMERICAN NATIONAL STANDARDS:
CSA 2.22 AND ANSI Z21.50 FOR VENTED DECORATIVE GAS APPLIANCES
IF INSTALLATION + OPERATION, ADD SERIAL
CSA /
INTERTEK
LOGO
BARCODE LABEL ON THE OWNER'S MANUAL"
Builder Series 42
Product Name / Code
(MUST use title from Price Book)
ADD ____ ILLUSTRATED
ADD PRODUCT IMAGE
FOR INDOOR USE ONLY
NUMBER LABEL HERE
IF SEPARATE MANUALS, ADD "PLACE
ENGLISH
FRENCH PG. 71
W415-1541 / F / 03.12.19

Advertisement

loading
Need help?

Need help?

Do you have a question about the CB42PTR and is the answer not in the manual?

Questions and answers

Summary of Contents for Continental Fireplaces CB42PTR

  • Page 1 CB42NTR / CB42NTRE ADD PRODUCT CODE HERE (TRADE GOTHIC LT STD FONT) NATURAL GAS MODELS: ENGLISH CB42PTR / CB42PTRE PROPANE GAS MODELS: FRENCH PG. 71 INSTALLATION AND ADD MANUAL TITLE OPERATION MANUAL Builder Series 42 Product Name / Code SAFETY INFORMATION...
  • Page 2 safety information WARNING • This appliance is hot when operated and DANGER can cause severe burns if contacted. • Any changes or alterations to this appliance or its controls can be dangerous and is prohibited. HOT GLASS WILL CAUSE • Do not operate appliance before reading and BURNS.
  • Page 3 safety information WARNING • Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this appliance. • This appliance must not be connected to a chimney fl ue pipe serving a separate solid fuel burning appliance.
  • Page 4 table of contents general information gas installation rates and effi ciencies operation (electronic) installation overview operation (millivolt) rating plate information finish framing mobile home installation minimum framing dimensions dimensions 10.0 finishing venting requirements 10.1 safety barrier / door removal and typical vent installation installation special vent installations...
  • Page 5 Serial #: Model: Natural Gas: CB42NTR Propane: CB42PTR CB42NTRE CB42PTRE 1.0 general information When the appliance is installed at elevations above 4,500 ft (1371m), and in the absence of specifi c recommendations from the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of 4% for each additional 1,000 ft (305m).
  • Page 6 general information installation overview f i r e - p a r t s . c o m Recommended installation steps: 1. Determine venting requirements before deciding the fi nal location of the appliance. 2. Install rough framing (see “rough framing” section). 3.
  • Page 7 general information WARNING • Always light the pilot - whether for the fi rst time or if the gas supply has run out - with the glass door opened or removed. • Provide adequate clearance for servicing and operating the appliance. •...
  • Page 8 OF HEAT, NOT INTENDED FOR USE AS A HEAT OF HEAT, NOT INTENDED FOR USE AS A HEA B42NTR CB42NTR CB42PTR B42PTR APPLIANCE, NOT FOR USE WITH SOLID FUEL. APPLIANCE, NOT FOR USE WITH SOLID FUEL. APPLIANCE, NOT FOR USE WITH SOLID FUEL...
  • Page 9 general information dimensions f i r e - p a r t s . c o m W415-1541 / F / 03.12.19...
  • Page 10 2.0 venting requirements WARNING • Risk of fi re. Maintain specifi ed air space clearances to vent pipe and appliance. • The vent system must be supported every 3’(0.9m) for both vertical and horizontal runs. Use support ring assembly W010- 0067 or equivalent non-combustible strapping to maintain the minimum clearance to combustibles for both vertical and horizontal runs.
  • Page 11 venting requirements Horizontal runs may have a 0” rise per foot or 0mm rise per meter however for optimum performance it is recommended that all horizontal runs have a minimum 1/4” rise per foot or 21mm rise per meter using fl exible venting. For safe and proper operation of the appliance, follow the venting instructions exactly.
  • Page 12 venting requirements 16" (40.6cm) minimum f i r e - p a r t s . c o m 40 ft (12m) maximum 3 ft (1m) minimum 20" (50.8cm) maximum 24 1/8" (61.3cm) 24 1/8" minimum plus (61.3cm) rise* REAR VENT * See "venting"...
  • Page 13 venting requirements special vent installations 2.2.1 periscope termination Use the periscope kit to locate the air termination above grade. The periscope must be installed so that when fi nal grading is completed, the bottom air slot is located a minimum 12” (305mm) above grade. The maximum allowable vent length (including both rise and run) is 10’...
  • Page 14 venting requirements minimum air terminal location clearances Covered balcony applications ††* = 3 feet = 2 x ACTUAL (0.9m) (4.6m) note: INSTALLATIONS Wall terminals are for illustration purposes only. Size and shapes may vary. CANADA U.S.A. 12” (30.5cm) 12” (30.5cm) Clearance above grade, veranda porch, deck or balcony.
  • Page 15 venting requirements venting application fl ow chart TOP EXIT Horizontal Termination Vertical Termination Vertical rise is equal Vertical rise is equal Vertical rise is less Vertical rise is less to or greater than to or greater than than horizontal run than horizontal run the horizontal run the horizontal run...
  • Page 16 venting requirements elbow vent length values Feet Inches Millimeters 1° 0.03 12.7 15° 0.45 152.4 30° 11.0 279.4 45° 1.35 16.0 406.4 90°* 32.0 812.8 * The fi rst 90° offset has a zero value and is shown in the formula as - 90° * The fi...
  • Page 17 venting requirements ) > (V Simple venting configuration See graph to determine the required vertical rise V for the required horizontal run H (only one 90° elbow) 150 (381) 147 (373) REQUIRED VERTICAL 100 (254) RISE IN INCHES (CENTIMETERS) V 57 (145) 50 (127) 8 (20.3)
  • Page 18 venting requirements rear exit horizontal termination ) < (V Simple venting configuration See graph to determine the required vertical rise V for the required (only two 90° elbows) horizontal run H 40 (12.2) 38.3 (11.7) REQUIRED 30 (9.1) VERTICAL RISE IN FEET 20 (6.1) (METERS) V 10 (3.1)
  • Page 19 venting requirements ) > (V Simple venting configuration See graph to determine the required vertical rise V for the (only two 90° elbows) required horizontal run H 150(3810) 150(3810) 147 (3733.8 147 (3733.8 Simple venti REQUIRED (only on VERTICAL RISE IN 100 (2540) 100 (2540) INCHES...
  • Page 20 venting requirements top and rear exit vertical termination ) < (V See graph to determine the required vertical rise V for the Simple venting configurations. required horizontal run H 40 (12.2) 30 (9.1) REQUIRED VERTICAL RISE IN FEET (METERS)V 20 (6.1) 10 (3.1) 3 (0.9) 5 (1.5)
  • Page 21 venting requirements ) > (V Simple venting configurations. See graph to determine the required vertical rise V for the required horizontal run H 20 (6.1) 19 (5.8) REQUIRED VERTICAL 10 (3.1) RISE IN FEET (METERS)V 3 (0.9) (1.5) (3.1) (4.6) (6.1) (7.6) (9.1)
  • Page 22 venting requirements 2.10 rear exit WARNING • Failure to create a seal to the fi rebox with the exhaust collar assembly will cause the appliance to function improperly and can cause injury or property damage. Remove the safety barrier and glass front (see "safety barrier / door removal and installation"...
  • Page 23 venting requirements 2.12 top exit WARNING • Failure to install the cover plate and gasket will cause the appliance to function improperly and can cause injury or property damage. This appliance is factory shipped as a rear vent model equipped with a #44 burner orifi ce. This orifi ce size is suitable for rear vent installations with 0"...
  • Page 24 3.0 rough framing note: When using optional fi nishing accessories, the framing dimensions and fi nishing materials may differ from what is outlined in the section below; refer to the leafl et instructions supplied in the accessory kit for specifi c framing and fi...
  • Page 25 rough framing minimum framing dimensions HORIZONTAL VENT SECTIONS: A minimum of 1" (25mm) at the bottom and sides and 3" (76mm) at the top of the vent pipe on all horizontal runs to combustibles is required. Use fi restop spacer W010-3440 (supplied). note: The minimum clearances from the top of the horizontal vent pipe to combustible materials may be reduced from 3"...
  • Page 26 rough framing minimum enclosure clearances TOP VENT f i r e - p a r t s . c o m 34 5/8" (87.9cm) TOP EXIT ENCLOSURE The appliance requires a minimum enclosure height of 50 1/2" (128.3cm). For temperature requirements, the enclosure space around and above the appliance must be left unobstructed.
  • Page 27 rough framing MINIMUM REAR VENT CLEARANCES For rear vent termination not exceeding 10" (254mm) of horizontal vent run. f i r e - p a r t s . c o m REAR EXIT ENCLOSURE The appliance requires a minimum enclosure height of 41 5/8" (105.7cm). For temperature requirements, the enclosure space around and above the appliance must be left unobstructed.
  • Page 28 rough framing MAXIMUM REAR VENT CLEARANCES (EXAMPLE 1) For rear vent termination exceeding 10" (254mm). f i r e - p a r t s . c o m REAR EXIT ENCLOSURE The appliance requires a minimum enclosure height of 41 5/8" (105.7cm). For temperature requirements, the enclosure space around and above the appliance must be left unobstructed.
  • Page 29 rough framing MAXIMUM REAR VENT CLEARANCES (EXAMPLE 2) f i r e - p a r t s . c o m REAR EXIT ENCLOSURE The appliance requires a minimum enclosure height of 41 5/8" (105.7cm). For temperature requirements, the enclosure space around and above the appliance must be left unobstructed.
  • Page 30 rough framing note: For heavier fi nishing materials such as marble, we recommend adding extra support to the frame. Ensure there is adequate fl oor support for the appliance and fi nishing material. Before framing your appliance, determine vent requirements before deciding the fi nal location of the appliance. After rough framing, place the appliance in its fi...
  • Page 31 4.0 venting installation WARNING • Ensure to unpack all loose materials from inside the fi rebox prior to connecting the gas and electrical supply • If your appliance is supplied with a remote, ensure the remote receiver is in the “OFF” position prior to connecting the gas and electrical supply to the appliance.
  • Page 32 venting installation horizontal installation WARNING • The fi restop assembly must be installed with the vent shield to the top. • Terminals must not be recessed into a wall or siding more than the depth of the return fl ange of the mounting plate.
  • Page 33 venting installation using either fl exible vent components WARNING • Do not allow the inner fl ex pipe to bunch up on horizontal or vertical runs and elbows. Keep it pulled tight. • Spacers are attached to the inner fl ex pipe at predetermined intervals to maintain an even air gap to the outer fl...
  • Page 34 venting installation 4.3.2 vertical air terminal installation WARNING • Maintain a minimum 2” (51mm) space between the air inlet base and the storm collar. note: Fastening hardware provided with appropriate roof terminal and liner kits. Fasten the roof support to the roof using 6 screws. The roof support is optional.
  • Page 35 venting installation 4.3.4 horizontal air terminal installation WARNING • Risk of fi re! Do not allow loose materials or insulation to touch the vent pipe. Remove insulation to allow for the installation of the attic shield and to maintain clearances to combustibles. Move the appliance into position.
  • Page 36 venting installation 4.3.5 vertical air terminal installation WARNING • Maintain a minimum 2” (51mm) space between the air inlet base and the storm collar. note: Fastening hardware provided with appropriate roof terminal and liner kits. Before attaching elbows to the collars on the back of the appliance, 1 1/2” (38.1mm) will need to be trimmed off the 4”...
  • Page 37 venting installation vertical through existing chimney WARNING • Risk of fi re. • Co-axial to co-linear venting confi gurations must only be used in a non-combustible chimney or enclosure. Installation in a combustible enclosure could result in a fi re. This appliance is designed to be attached to a 3”...
  • Page 38 venting installation 4.4.1 restricting vertical vents WARNING • Turn off gas and electrical supply before servicing the appliance. • Appliance may be hot. Do not service until appliance is cool. • For safe and proper operation of the appliance, follow the venting instructions exactly. •...
  • Page 39 5.0 electrical information electronic wiring diagram WARNING • Do not wire 110 volts to the valve or wall switch. *Some jurisdisctions may prohibit the use of a standing pilot. In ACS/IPI these jurisdictions, the anti-condensation switch shall be SWITCH* disconnected to comply with local codes. To disconnect, (OPTIONAL) locate the white connector at the end of the white and blue wires of the ACS switch and disconnect.
  • Page 40 electrical information battery back-up installation WARNING • Ensure the gas and electrical power to the appliance is turned off. • Appliance may be hot. Do not service until the appliance has cooled. note: In the event of a power failure, your appliance can be operated using the battery back-up supplied. Before beginning installation, disconnect the gas and electrical power supply from the appliance.
  • Page 41 electrical information optional wall switch WARNING • Do not connect either the wall switch, thermostat or gas valve directly to 110 volt electricity. For ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a convenient location.
  • Page 42 6.0 gas installation WARNING • Risk of fi re, explosion, or asphyxiation. Ensure there are no ignition sources such as sparks or open fl ames. • Support gas control when attaching gas supply pipe to prevent damaging gas line. • Always light the pilot whether for the fi...
  • Page 43 7.0 operation (electronic) WARNING • If you do not follow these instructions exactly, a fi re or explosion may result causing property damage, personal injury, or loss of life. • If applicable, always light the pilot whether for the fi rst time or if the gas supply has run out with the glass door opened or removed.
  • Page 44 8.0 operation (millivolt) WARNING • If you do not follow these instructions exactly, a fi re or explosion may result causing property damage, personal injury, or loss of life. • If applicable, always light the pilot whether for the fi rst time or if the gas supply has run out with the glass door opened or removed.
  • Page 45 9.0 fi nish framing minimum framing dimensions f i r e - p a r t s . c o m 35" 88.9cm 2 3/16" (56mm) 7 3/16" (182mm) 18 9/16" 47.2cm W415-1541 / F / 03.12.19...
  • Page 46 10.0 fi nishing WARNING • Risk of fi re! • Never obstruct the front opening of the appliance. • The front of the appliance must be fi nished with any non-combustible materials such as brick, marble, granite, etc., provided that these materials do not go below the specifi ed dimension, as illustrated. •...
  • Page 47 fi nishing 10.2 front hood installation note: This hood must be installed, if it has not already been factory installed. Remove safety door and barrier. Remove the securing screws from the top of the fi rebox, as shown. Install the front hood, ensuring it is angled downward when installed. Reinstall the previously removed securing screws.
  • Page 48 fi nishing 10.3 non-combustible facing material WARNING Non-combustible facing material must not project more than 4” (101.6mm) from the face of the door (all four sides). If greater projections are desired, increase the clearance to the sides, bottom and top by 2” (50.8mm) for every additional 1”...
  • Page 49 fi nishing 10.4 minimum mantel clearances WARNING • Risk of fi re. Maintain all specifi ed air space clearances to combustibles. Failure to comply with these instructions may cause a fi re or cause the appliance to overheat. Ensure all clearances (i.e. back, side, top, vent, mantel, front, etc.) are clearly maintained.
  • Page 50 fi nishing 10.5 recessed installation WARNING • Installing a television or other electronics above the appliance may cause discolouration, melting, or damage to the electronics. Use clearances as guidelines and refer to your manufacturer's instructions for further information. f i r e - p a r t s . c o m MINIMUM CLEARANCES CHART 6"...
  • Page 51 fi nishing 10.6 nailing tab installation Nailing tabs are provided as part of the frames, as shown. To determine the final location and where to bend the nailing tabs you must first determine the thickness of your finishing material (i.e. drywall).
  • Page 52 fi nishing 10.7 log placement WARNING • Failure to position the logs in accordance with these diagrams or failure to use only logs specifi cally approved with this appliance may result in property damage or personal injury. • Logs must be placed in their exact location in the appliance. Do not modify the proper log positions, since appliance may not function properly and delayed ignition may occur.
  • Page 53 fi nishing 10.8 glowing embers WARNING • Do not block or close off the burner ports. Blocked ports can cause an incorrect fl ame pattern, carbon deposits and delayed ignition. Tear the embers into pieces and loosely layer above the burner ports covering the burner area. Care should be taken to shred the embers into thin, small irregular pieces as only the exposed edges of the fi...
  • Page 54 11.0 optional blower installation WARNING • Ensure the appliance is completely cool before starting installation. • To avoid danger of suffocation, keep the packaging bag away from babies and children. Do not use in cribs, beds, carriages, or play pens. This bag is not a toy. Knot before throwing away. 1.
  • Page 55 12.0 adjustment 12.1 pilot burner adjustment Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direction to reduce the gas fl ow. PILOT 3/8” - 1/2” ELECTRODE BURNER (9.5mm - 12.7mm) ELECTRONIC 3/8” - 1/2” ILLUSTRATED (9.5mm - 12.7mm) FLAME MUST...
  • Page 56 adjustments 12.2 venturi adjustment This appliance has an air shutter that has been factory set open according to the chart below: VENTURI Regardless of venturi orientation, closing the air shutter will cause a more BURNER yellow flame, but can lead to carbonization. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports.
  • Page 57 13.0 maintenance WARNING • Turn off the gas and electrical power before servicing the appliance. • Appliance may be hot. Do not service until appliance has cooled. • Do not use abrasive cleaners on glass. • Do not paint the pilot assembly. This appliance and its venting system should be inspected before use and at least annually by a qualifi...
  • Page 58 maintenance note: Clean fl ame sensor using a fi ne emery cloth or a synthetic scrub pad (such as Scotch-Brite™) to remove any oxides. Clean the pilot assembly using a vacuum with a soft brush attachment. It is important that the pilot assembly is not painted.
  • Page 59 14.0 replacement parts WARNING • Failure to position the parts in accordance with this manual or failure to use only parts specifi cally approved with this appliance may result in property damage or personal injury. Contact your dealer for questions concerning prices and policies on replacement parts. Normally, all parts can be ordered through your Authorized dealer / distributor.
  • Page 60 replacement parts f i r e - p a r t s . c o m W415-1541 / F / 03.12.19...
  • Page 61 replacement parts f i r e - p a r t s . c o m W415-1541 / F / 03.12.19...
  • Page 62 replacement parts f i r e - p a r t s . c o m W415-1541 / F / 03.12.19...
  • Page 63 15.0 accessories f i r e - p a r t s . c o m W415-1541 / F / 03.12.19...
  • Page 64 16.0 troubleshooting (electronic) WARNING • Always light the pilot whether for the fi rst time or if the gas supply has run out, with the glass door open or removed. • Turn off gas and electrical power before servicing the appliance. •...
  • Page 65 troubleshooting (electronic) symptom problem test solution Pilot will not light. Makes Wiring: short, loose, or damaged Verify the thermocouple/sensor is clean and the wiring is undamaged. Verify the interrupter block is not damaged or too tight. Verify noise with no spark at connections connections from pilot assembly are tight;...
  • Page 66 troubleshooting (electronic) symptom problem test solution Motor is turning, Receiver batteries low. Replace batteries. frequent beeping occurs. Lights or blower Control module switch in Verify ON/OFF switch is in the “I” position which denotes on. won’t function (if wrong position. equipped).
  • Page 67 17.0 troubleshooting (millivolt) WARNING • Always light the pilot whether for the fi rst time or if the gas supply has run out, with the glass door open or removed. • Turn off gas and electrical power before servicing the appliance. •...
  • Page 68 troubleshooting (millivolt) symptom problem test solution Pilot will not light. No spark at pilot burner. Check if pilot can be lit by a match. Check that the wire is connected to the push button ignitor. Check if the push button ignitor needs tightening. PILOT Replace the wire if the wire insulation is broken or frayed.
  • Page 69 18.0 warranty Continental® products are manufactured under the strict standard of the world recognized ISO 9001 : 2015 Quality Management System. Continental® products are designed with superior components and materials assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fi red at a quality test station. The complete appliance is again thoroughly inspected by a qualifi...
  • Page 70 f i r e - p a r t s . c o m 7200, Route Transcanadienne, Montréal, Québec H4T 1A3 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 103 Miller Drive, Crittenden, Kentucky, USA 41030 Phone: 1-866-820-8686 continentalfireplaces.com...
  • Page 71 CB42NTR / CB42NTRE ADD PRODUCT CODE HERE (TRADE GOTHIC LT STD FONT) MODÈLES DE GAZ NATUREL CB42PTR / CB42PTRE MODÈLES DE PROPANE FRANÇAIS FRANÇAIS MANUEL D'INSTALLATION ADD MANUAL TITLE ET D'OPÉRATION Product Name / Code Série Contracteur 42 CONSIGNES DE SÉCURITÉ...
  • Page 72 consignes de sécurité AVERTISSEMENT • Cet appareil est chaud lorsqu’il AVERTISSEMENT fonctionne et peut causer de graves brûlures en cas de contact. • Toute modifi cation apportée à cet appareil ou aux contrôles peut être LA VITRE CHAUDE CAUSERA dangereux et est interdit. DES BRÛLURES.
  • Page 73 consignes de sécurité AVERTISSEMENT • N’utilisez pas une souffl erie intégrée, un échangeur de chaleur intégré ni un autre accessoire non approuvé pour cet appareil. • Cet appareil ne doit pas être raccordé au conduit d’une cheminée desservant un autre appareil de chauffage à...
  • Page 74 table des matières information électrique information générales schéma de câblage électronique 110 taux et effi cacités installation du sauvegarde de pile 111 vue d'ensemble d'installation interrupteur mural optionnel information à propos de la plaque branchement de gaz d'homologation fonctionnement (électronique) installation dans une maison mobile 78 fonctionnement (millivolt) dimensions...
  • Page 75 # de Série: Modèle: Gaz Naturel: CB42NTR Propane: CB42PTR CB42NTRE CB42PTRE 1.0 information générales Lorsque l'appareil est installé à des élévations dépassant 4 500 pieds (1372m), et en l'absence de recommendations spécifi ques de l'autorité compétente locale, l'indice certifi é du débit à haute altitude devra être réduit au taux de 4% pour chaque 1 000 pieds (305m) supplémentaires.
  • Page 76 information générales vue d'ensemble d'installation f i r e - p a r t s . c o m Étapes d'installation recommandées: 1. Determinez les exigences d'évacuation avant de determinez le position fi nale de l'appareil. 2. Installez l'encadrement approximatif (voir la section « encadrement approximatif »). 3.
  • Page 77 information générales AVERTISSEMENT • Allumez toujours la veilleuse, que ce soit pour la première fois ou lorsque l'approvisionnement en gaz est épuisé, avec la porte vitrée ouverte ou retirée. • Prévoyez un accès suffi sant pour entretenir et opérer l'appareil. •...
  • Page 78 OF HEAT, NOT INTENDED FOR USE AS A HEATING OF HEAT, NOT INTENDED FOR USE AS OF HEAT, NOT INTENDED FOR USE AS B42NTR CB42NTR CB42PTR B42PTR B42PTR APPLIANCE, NOT FOR USE WITH SOLID FUEL. APPLIANCE, NOT FOR USE WITH...
  • Page 79 information générales dimensions f i r e - p a r t s . c o m W415-1541 / F / 03.12.19...
  • Page 80 2.0 exigences d'évacuation AVERTISSEMENT • Risque d’incendie. Conservez les dégagements nécessaires au conduit d’évent et à l’appareil. • Les courses horizontales et verticales du système doivent être supportées à tous les 3 pi (0,9m). Utilisez l’ensemble de support mural Wolf Steel W010-0067 ou des attaches incombustibles équivalents afi n de maintenir le dégagement aux matériaux combustibles pour les courses verticales et horizontales.
  • Page 81 exigences d'évacuation Pour une performance optimale de l’appareil et une apparence optimale des fl ammes, gardez la longueur des évents et le nombre de coudes au minimum. La prise d’air de la terminaison extérieure doit demeurer dégagée en tout temps. Vérifi ez la prise d’air de la terminaison au moins une fois l’an pour vous assurer qu’elle n’est pas obstruée ni endommagée.
  • Page 82 exigences d'évacuation installations typiques d'évents 16" (40,6cm) minimum f i r e - p a r t s . c o m 40 pi (12m) maximum 24" (61cm) 3 pi (1m) maximum minimum 8" (203mm) minimum 34 5/8" (87,9cm) ÉVACUATION SUR LE DESSUS W415-1541 / F / 03.12.19...
  • Page 83 exigences d'évacuation 16" (40,6cm) minimum f i r e - p a r t s . c o m 40 pi (12m) maximum 3 pi (1m) minimum 20" (50,8cm) maximum 24 1/8" (61,3cm) 24 1/8" minimum plus la (61,3cm) pente* ÉVACUATION SUR L'ARRIÈRE * Voir la section «...
  • Page 84 exigences d'évacuation installations particulières d'évents 2.2.1 ensemble périscopique Utilisez l’ensemble périscopique afi n de positionner la terminaison au-dessus du niveau du sol. L’ensemble périscopique doit être installé de façon à ce que la fente d’air du bas soit située à un minimum de 12 pouces (305mm) au-dessus du niveau du sol.
  • Page 85 exigences d'évacuation emplacements et dégagements minimaux de la terminaison Applications pour balcon couvert ††* = 3 feet = 2 x ACTUAL (4.6m) (0.9m) note: INSTALLATIONS Les terminaux du mur sont à des fi ns d’illustration seulement. La taille et les formes peuvent varier. CANADA É.-U.
  • Page 86 exigences d'évacuation charte d'application des évacuations ÉVACUATION SUR LE DESSUS Terminaison Horizontale Terminaison Verticale La course verticale La course verticale La course verticale La course verticale est plus petite est plus petite est plus grande ou est plus grande ou que la course égale à...
  • Page 87 exigences d'évacuation valeurs du coude en longueurs d'évent Pieds Pouces Millimètres 1° 0,03 12,7 15° 0,45 152,4 30° 11,0 279,4 45° 1,35 16,0 406,4 90°* 32,0 812,8 * La première déviation de 90° a une valeur zéro et est illustrée dans la formule comme - 90°. * La première déviation de 45°...
  • Page 88 exigences d'évacuation ) > (V Configuration d'évacuation simple Consultez le graphique pour déterminer la course verticale nécessaire V par rapport à la course horizontale requise H (un coude de 90° seulement) 150 (381) 147 (373) COURSE VERTICALE 100 (254) REQUISE EN POUCES (CENTIMÈTRES)V 57 (145)
  • Page 89 exigences d'évacuation évacuation sur l'arrière terminaison horizontale ) < (V Configuration d'évacuation simple See graph to determine the required vertical rise V for the required (deux coudes de 90° seulement) horizontal run H 40 (12,2) 38,3 (11,7) COURSE 30 (9,1) VERTICALE REQUISE 20 (6,1)
  • Page 90 exigences d'évacuation ) > (V Configuration d'évacuation simple Consultez le graphique pour déterminer la course verticale (deux coudes de 90° seulement) nécessaire V par rapport à la course horizontale requise H 12,5 (3,8) 12,25 (3,7) 150(3810) 147 (3733.8 COURSE Simple venti COURSE (only on VERTICALE...
  • Page 91 exigences d'évacuation évacuation sur l'arrière et au dessus terminaison verticale ) < (V Consultez le graphique pour déterminer la course verticale Configurations d'évacuation simples. nécessaire V par rapport à la course horizontale requise H 40 (12,2) 30 (9,1) COURSE VERTICALE REQUISE EN PIEDS 20 (6,1)
  • Page 92 exigences d'évacuation ) > (V Configurations d'évacuation simples. Consultez le graphique pour déterminer la course verticale nécessaire V par rapport à la course horizontale requise H 20 (6,1) 19 (5,8) COURSE VERTICALE 10 (3,1) REQUISE EN PIEDS 3 (0,9) (MÈTRES) V (1,5) (3,1) (4,6)
  • Page 93 exigences d'évacuation 2.10 évacuation à l'arrière AVERTISSEMENT • Il est essential que le couvercle d'évacuation soit installé. Si non, l'appareil ne fonctionnera pas correctement et pourrait causer des blessures ou des dommages matériels. Enlevez l'écran de protection et vitre de la porte (voir la section « installation et enlevement de l'écran de protection et la porte »).
  • Page 94 exigences d'évacuation 2.12 évacuation sur le dessus AVERTISSEMENT • Il est essential que le couvercle d'évacuation soit installé. Si non, l'appareil ne fonctionnera pas correctement et pourrait causer des blessures ou des dommages matériels. Cet appareil est fabriqué équipé avec un #44 modèle d'orifi ce avec l'évacuation arrière. Cet taille d'orifi...
  • Page 95 3.0 encadrement approximatif note: Lorsque vous installez les accessoires de fi nition optionelles, les dimensions de l’ossature et les matériaux de fi nition peuvent différer de ce qui est décrit dans ces instructions ci-dessous, voir les instructions fournies dans le trousse de l’accessoire pour les spécifi cations détaillées. AVERTISSEMENT •...
  • Page 96 encadrement approximatif dégagements minimaux de l'ossature SECTIONS D’ÉVENTS HORIZONTALES: Un dégagement minimal aux matériaux combustibles de 1" (25mm) au-dessous et sur les côtés de l’évent et de 3" (76mm) au-dessus doit être maintenu sur toutes les courses horizontales. Utilisez l’espaceur coupe-feu W010-3440 (fourni). note: Les dégagements minimaux entre le haut de l’évent et les matériaux combustibles peut être réduite de 3"...
  • Page 97 encadrement approximatif dégagements minimaux de l'enceinte ÉVACUATION SUR LE DESSUS f i r e - p a r t s . c o m 34 5/8" (87,9cm) ENCEINTE AVEC ÉVACUATION SUR LE DESSUS L'enceinte de l'appareil doit avoir une hauteur minimale de 50 1/2" (128,3cm). Afi n de respecter les contraintes de température, l'espace à...
  • Page 98 encadrement approximatif DÉGAGEMENTS MINIMAUX D'ÉVACUATION À L'ARRIÈRE Pour la ventilation ne dépassement pas 10" (254mm) de section horizontale de ventilation. f i r e - p a r t s . c o m ENCEINTE AVEC ÉVACUATION À L'ARRIÈRE L'enceinte incombustible de l'appareil doit avoir une hauteur minimale de 41 5/8" (105,7cm). Afi n de respecter les contraintes de température, l'espace à...
  • Page 99 encadrement approximatif DÉGAGEMENTS MAXIMAUX D'ÉVACUATION À L'ARRIÈRE (EXEMPLE 1) Pour la ventilation arrière dépassement de 10" (254mm). f i r e - p a r t s . c o m ENCEINTE AVEC ÉVACUATION À L'ARRIÈRE L'enceinte de l'appareil doit avoir une hauteur minimale de 41 5/8" (105,7cm). Afi n de respecter les contraintes de température, l'espace à...
  • Page 100 encadrement approximatif DÉGAGEMENTS MAXIMAUX D'ÉVACUATION À L'ARRIÈRE (EXEMPLE 2) f i r e - p a r t s . c o m ENCEINTE AVEC ÉVACUATION À L'ARRIÈRE L'enceinte de l'appareil doit avoir une hauteur minimale de 41 5/8" (105,7cm). Afi n de respecter les contraintes de température, l'espace à...
  • Page 101 encadrement approximatif note: Pour les matériaux de fi nition plus lourds comme du marbre, nous vous recommandons d'ajouter un support additionnel à l'ossature. Assurez-vous que le support de plancher est adéquat pour l'appareil et le matériau de fi nition. Avant d'encadrer votre appareil, déterminez les exigences de ventilation avant de décider de l'emplacement fi nale de l'appareil.
  • Page 102 4.0 installation d'évacuation AVERTISSEMENT • Avant d’effectuer les branchements pour l’alimentation en gaz et électronique, assurez-vous de retirer toute composante non fi xée à l’intérieur de la chambre de combustion. • Si votre appareil comprend un système de télécommande, assurez-vous que le récepteur est à la position «...
  • Page 103 installation verticale Cette confi guration s’applique lorsque l’évacuation se fait à travers un toit. Des ensembles d’installation pour les différentes pentes de toit sont disponibles chez votre détaillant autorisé. Voir la section « accessoires » dans le manuel du propriétairepour commander l’ensemble spécifi que dont vous avez besoin.
  • Page 104 4.3.1 installation de la terminaison horizontale Étirez la gaine fl exible intérieure à la longueur requise en tenant compte de la longueur additionnelle nécessaire ADD FASTENER TYPE pour la surface du mur fi ni. Appliquez un généreux joint de scellant à haute température Mill Pac (W573- 0007) (non fourni).
  • Page 105 4.3.2 installation de la terminaison verticale AVERTISSEMENT • Conservez un espace minimale de 2 po (51mm) entre la base de la prise d’air et le collet de solin. Matériel de fi xation fourni avec les ensembles de terminal pour toit et raccord appropriées. Fixez le support de toit au toit à...
  • Page 106 4.3.4 installation de la terminaison horizontale AVERTISSEMENT • Risque d'incendie! Évitez que l'isolant touche au conduit d'évacuation. Retirez l'isolant pour permetter l'installation de l'écran protecteur de grenier et pour maintenir les dégagements aux matériaux combustibles. Mettez l’appareil en place. Mesurez la longueur #10x2"...
  • Page 107 4.3.5 installation de la terminaison verticale AVERTISSEMENT • Conserves un espace minimal de 2” (51mm) entre la base de la prise d’air et le collet de solin. note: Avant de fi xer les coudes aux collets à l’arriére de l’appareil, enlevez 1 1/2” (38.1mm) au collet de 4” (101.6mm) Matériel de fi...
  • Page 108 terminaison verticale à travers une cheminée existante AVERTISSEMENT • Risque d’incendie • Les confi gurations d’évacuation coaxiales à colinéaires ne doivent être utilisées que dans une cheminée ou une enceinte de nature incombustible. Une installation dans une enceinte combustible peut causer un incendie. Cet appareil est conçu pour être raccordé...
  • Page 109 4.4.1 renstreignant des évents verticaux AVERTISSEMENT • Mettez hors tension de gaz et de l'alimentation électrique avant d'intervenir sur l'appareil. • L'appareil peut être chaud, pas de service jusqu'à ce que l'appareil est refroidi. • Pour l'utilisation sûr et correcte de l'apapreil, suivez les instructions d'évacuation exactement. •...
  • Page 110 5.0 information électrique schéma de câblage électronique AVERTISSEMENT • Ne raccordez pas l’interrupteur mural ou la soupape de gaz à l’alimentation électrique (110 volts). *Certains jurisdisctions peuvent interdire avec l’utilisation d’une veilleuse permanente. Dans ces jurisdictions, l’interrupteur INTERRUPTEUR anti-condensation seront débranché pour conformer aux ACS/IPI* codes locaux.
  • Page 111 information électrique installation du sauvegarde de pile AVERTISSEMENT • Assurez-vous que l'alimentation électrique et le gaz à l'appareil est éteint. • Assurez-vous que l'appareil est complètement refroidi avant de commencer service. note: En cas d'une panne de courrant, votre appareil peut fonctionner utilisant le sauvegarde de pile fourni. Avant commencer l'installation, coupez le gaz et l'alimentation électrique de l'appareil.
  • Page 112 information électrique interrupteur mural optionnel AVERTISSEMENT • Ne raccordez pas l’interrupteur mural, le thermostat ou la soupape de gaz à l’alimentation électrique de 110 volts Pour faciliter l’accès, un interrupteur mural ou un thermostat millivolt optionnel (lorsque cela est permis par les codes locaux) peut être installé...
  • Page 113 6.0 branchement de gaz AVERTISSEMENT • Risque d’incendie, d’explosion, ou d’asphyxie. Assurez-vous qu’il n’y ait aucune source d’allumage comme des étincelles ou une fl amme nue. • Soutenez le contrôle du gaz lorsque vous attachez le tuyau pour éviter de plier la conduite de gaz. •...
  • Page 114 7.0 fonctionnement (électronique) AVERTISSEMENT • Si ces instructions ne sont pas suivies à la lettre, un incendie ou une explosion pourraient s’ensuivre, causant des dommages matériels, des blessures corporelles ou des pertes de vie. • Si applicable, allumez toujours la veilleuse, que ce soit pour la première fois ou lorsque l’approvisionnement en gaz est épuisé, avec la porte vitrée ouverte ou retirée.
  • Page 115 8.0 fonctionnement (millivolt) AVERTISSEMENT • Si ces instructions ne sont pas suivies à la lettre, un incendie ou une explosion pourraient s’ensuivre, causant des dommages matériels, des blessures corporelles ou des pertes de vie. • Allumez toujours la veilleuse, que ce soit pour la première fois ou lorsque l’approvisionnement en gaz est épuisé, avec la porte vitrée ouverte ou retirée Assurez-vous que l’arrivée de gaz au brûleur est continue avant de réinstaller la porte.
  • Page 116 9.0 encadrement fi ni fonctionnement (millivolt) dimensions minimaux de l'encadrement f i r e - p a r t s . c o m 35" 88,9cm 2 3/16" (56mm) 7 3/16" (182mm) 18 9/16" 47,2cm W415-1541 / F / 03.12.19...
  • Page 117 10.0 fi nitions AVERTISSEMENT • Risque d'incendie! • N'obstruez jamais l'ouverture sur le devant de l'appareil. • La fi nition de la façade doit être fait avec de matériau incombustible comme de la brique, du marbre, du granite, etc., sous réserve que ces matériaux ne dépassent pas le dimension spécifi é, comme illustré. •...
  • Page 118 fi nitions 10.2 installation de l'hotte avant note: Cette hotte doit être installé si elle n'a pas déjà été installée en usine. Enlevez la porte et l'écran de protection. Retirez les vis de fi xation de la partie supérieure de l'appareil, comme illustré. Installez l'avant hotte.
  • Page 119 fi nitions 10.3 matériau de fi nition incombustible AVERTISSEMENT Les matériaux de finition incombustibles ne doivent pas dépasser de plus 4” (101,6mm) la façade de la porte (sur toutes côtés). Si des projections plus grandes sont requises, augmentez les dégagements des côtés et du dessus de 2"...
  • Page 120 fi nitions 10.4 dégagements minimaux de tablette AVERTISSEMENT • Rique d’incendie. Conservez tous les dégagements aux matériaux combustibles spécifi és. Incapacité de se conformer à ces instructions peut causer un incendie ou une surchauffe. Assurez-vous que tous les dégagements (arrière, côtés, dessus, évents, tablette, façade, etc.) sont respectés à la lettre. •...
  • Page 121 fi nitions 10.5 installation encadrée AVERTISSEMENT • Installation d'une télévision ou d'autres appareils électroniques au-dessus de l'appareil peut provoquer une décoloration, la fonte, détérioration, ou des autres dommages aux composants électroniques. Utiliser les autorisations que les lignes directrices et référer aux instructions qui se trouvent dans le manuel d'installation du fabricant de votre électroniques.
  • Page 122 fi nitions 10.7 disposition des bûches AVERTISSEMENT • Omettre de positionner les bûches conformément aux schémas ou omettre d’utiliser uniquement des bûches spécifi quement approuvées pour cet appareil peut causer des dommages matériels ou des blessures corporelles. • Les bûches doivent être placées correctement à l’intérieur de l’appareil. Ne changez pas la position des bûches car l’appareil risque de ne pas fonctionner adéquatement et un retard d’allumage risque de se produire.
  • Page 123 fi nitions 10.8 braises incandescentes AVERTISSEMENT • Obstruez pas ni fermer les orifi ces du brûleur. Le blocage des orifi ces du brûleur peut créer une fl amme irrégulière, des dépôts de carbone et un retard d’allumage. Déchirez les braises incandescentes en morceaux et placez une couche lâche sur le grillage du brûleur. Les braises devraient être déchirées très soigneusement en petits morceaux minces irréguliers, car seuls les côtés des fi...
  • Page 124 11.0 installation de la souffl erie optionnelle AVERTISSEMENT • Assurez-vous que l'appareil est complètement refroidi avant de commencer l'installation. • Afi n d'éviter les risques de suffocation, gardez le sac d'emballage loin des bébés et des jeunes enfants. Ne le laissez pas traîner dans les berceaux, les lits, les pousettes, ou les parcs de jeu. Ce sac n'est pas un jouet. Nouez-le avant de le jeter.
  • Page 125 12.0 réglages 12.1 réglage de la veilleuse Ajustez la vis de la veilleuse pour obtenir une fl amme de taille normale. Tournez vers la droite pour réduire l’apport de gaz. PILOT ELECTRODE ÉLECTRODE 3/8” - 1/2” VEILLEUSE BURNER (9,5mm - 12,7mm) 3/8”...
  • Page 126 adjustments 12.2 réglage du venturi L’ouverture du volet d’air a été préréglée en usine selon le tableau ci-dessous: Indépendamment de l’orientation du venturi, plus le volet est fermé, plus la VENTURI flamme est jaune et aura tendance à causer des dépôts de carbone. Plus le volet est ouvert, plus la flamme est bleue et plus elle a tendance à...
  • Page 127 13.0 entretien AVERTISSEMENT • Coupez l’alimentation en gaz et l’alimentation électrique avant de procéder à l’entretien de l’appareil. • L’appareil peut être chaud. Attendez qu’il soit refroidi avant d’en faire l’entretien. • N’utilisez pas de produits abrasifs. • Ne peinture pas l’assemblage de la veilleuse. Cet appareil et son système d’évacuation devraient être inspectés avant la première utilisation et au moins une fois l’an par un technicien de service qualifi...
  • Page 128 entretien note: Vous devrez nettoyer le capteur de fl amme à l’aide d’une morceau de de laine d’acier ou un tampon récurage (Scotch-Brite™) afi n de retirer toute trace d’oxydation. Nettoyez l’assemblage du pilote à l’aide d’un aspirateur muni d’une brosse souple. Il est important de ne pas peinturer l’assemblage de la veilleuse. •...
  • Page 129 14.0 pièces de rechange AVERTISSEMENT • Omettre de positionner les pièces conformément à ce manuel ou d’utiliser uniquement des pièces spécifi quement approuvées pour cet appareil peut causer des dommages matériels ou des blessures corporelles. Contactez votre détaillant pour les questions concernant les prix et la disponibilité des pièces de remplace- ment.
  • Page 130 pièces de rechange f i r e - p a r t s . c o m W415-1541 / F / 03.12.19...
  • Page 131 pièces de rechange f i r e - p a r t s . c o m W415-1541 / F / 03.12.19...
  • Page 132 pièces de rechange f i r e - p a r t s . c o m W415-1541 / F / 03.12.19...
  • Page 133 15.0 accessoires f i r e - p a r t s . c o m W415-1541 / F / 03.12.19...
  • Page 134 16.0 guide de dépannage (électronique) AVERTISSEMENT • Allumez toujours la veilleuse, que ce soit pour la première fois ou lorsque l’approvisionnement en gaz est épuisé, avec la porte vitrée ouverte ou retirée. • Coupez l’alimentation en gaz et l’alimentation électrique avant de procéder à l’entretien de l’appareil. •...
  • Page 135 guide de dépannage (électronique) symptôme problème solution La veilleuse ne s’allume Câblage: pénurie, connexion Vérifi ez qu’il n’y a pas de connexions desserrées du thermocouple ni sonde de fl amme. pas. Il y a du bruit mais desserrée (rectifi cation de la Vérifi...
  • Page 136 guide de dépannage (électronique) symptôme problème solution Les piles du récepteur ou Remplacez les piles. télécommmande sont faibles. Erreur de synchronisation. Réinitialiser le télécommande et le récepteur. Le télécommande est trop loin du Voir la section « schéma de câblage ». récepteur.
  • Page 137 17.0 guide de dépannage (millivolt) AVERTISSEMENT • Allumez toujours la veilleuse, que ce soit pour la première fois ou lorsque l’approvisionnement en gaz est épuisé, avec la porte vitrée ouverte ou retirée. • Coupez l’alimentation en gaz et l’alimentation électrique avant de procéder à l’entretien de l’appareil. •...
  • Page 138 guide de dépannage (millivolt) Une pellicule blanche Le souffre du combustible se Nettoyez la vitre avec un nettoyeur recommandé. ou grise se forme. dépose sur la vitre, les bûches NE PAS NETTOYER LORSQU’ELLE EST CHAUDE. ou les parois de la chambre de Si vous ne nettoyez pas les dépôts régulièrement, la vitre risque de rester combustion.
  • Page 139 18.0 garantie Les produits CONTINENTAL® sont fabriqués conformément aux normes strictes du Système de Gestion de la Qualité mondialement reconnu ISO 9001 : 2015. Les produits CONTINENTAL® sont conçus avec des composants et des matériaux de qualité supérieure, assemblés par des artisans qualifi...
  • Page 140 f i r e - p a r t s . c o m 7200, Route Transcanadienne, Montréal, Québec H4T 1A3 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 103 Miller Drive, Crittenden, Kentucky, USA 41030 Phone: 1-866-820-8686 continentalfireplaces.com...