Download Print this page
Anritsu Site Master Series Maintenance Manual
Anritsu Site Master Series Maintenance Manual

Anritsu Site Master Series Maintenance Manual

Personal swr/rl and fault location testers

Advertisement

Quick Links

A l l t e s t I n s t r u me n t s , I n c .
5 0 0 C e n t r a l A v e .
F a r mi n g d a l e , N J 0 7 7 2 7
P : ( 7 3 2 ) 9 1 9 - 3 3 3 9
F : ( 7 3 2 ) 9 1 9 - 3 3 3 2
a l l t e s t . n e t
s s a l e s @ a l l t e s t . n e t
T h e t e s t & me a s u r e me n t
e q u i p me n t y o u n e e d a t
t h e p r i c e y o u w a n t .
A l l t e s t c a r r i e s t h e w o r l d ' s l a r g e s t s e l e c t i o n o f
u s e d / r e f u r b i s h e d b e n c h t o p t e s t & me a s u r e me n t
e q u i p me n t a t 5 0 % t h e p r i c e o f n e w .
O O u r e q u i p me n t i s g u a r a n t e e d w o r k i n g , w a r r a n t i e d , a n d
a v a i l a b l e w i t h c e r t i f i e d c a l i b r a t i o n f r o m o u r i n - h o u s e s t a f f
o f t e c h n i c i a n s a n d e n g i n e e r s .
• 1 0 + f u l l t i me t e c h n i c i a n s w i t h o v e r 1 5 0 y e a r s o f
s p e c i a l i z a t i o n
• 9 0 d a y w a r r a n t y & 5 d a y r i g h t o f r e t u r n o n a l l
e q u i p me n t
• • 1 - 3 y e a r w a r r a n t i e s f o r n e w a n d
p r e mi u m- r e f u r b i s h e d e q u i p me n t
• E v e r y u n i t t e s t e d t o O E M s p e c i f i c a t i o n s
• S a t i s f a c t i o n g u a r a n t e e d
Y o u h a v e p l a n s , w e w i l l h e l p y o u a c h i e v e t h e m.
A n y p r o j e c t . A n y b u d g e t .
t
G e t a q u o t e t o d a y !
C C a l l ( 7 3 2 ) 9 1 9 - 3 3 3 9 o r e ma i l s a l e s @a l l t e s t . n e t .

Advertisement

loading
Need help?

Need help?

Do you have a question about the Site Master Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Anritsu Site Master Series

  • Page 1 T h e t e s t & me a s u r e me n t e q u i p me n t y o u n e e d a t t h e p r i c e y o u w a n t . A l l t e s t I n s t r u me n t s , I n c .
  • Page 2 S330A, S331, and S331A Personal SWR/ RL and and its components. These tests support the follow- Fault Location Testers. It describes the product and ing models of the Site Master series having any ver- provides performance verification procedures, parts sion of firmware; S110, S111, S112, S113, S330, replacement procedures, and a replaceable parts list.
  • Page 3 Test Port to the RF Input on the Equipment Required: MS2602A. · Spectrum Analyzer Set up the Spectrum Analyzer as follows: Anritsu Model MS2602A (a) Press Preset. Procedure: (b) Press Center and enter 1 GHz. (c) Press Span and enter 500 kHz.
  • Page 4 If the Site Master has gone into the hold mode, press the RUN/HOLD key to make · Spectrum Analyzer the measurement. Anritsu Model MS2602A Use the Spectrum Analyzer marker to measure the center of the response. The frequency should be 1000 Mhz ±75 kHz.
  • Page 5 S112 and S113: 6 dB ±1.2 dB Equipment Required: q S330 and S331: 6 dB ±1.2 dB · 20 dB offset, Anritsu SC5270 q S330A and S331A: 6 dB ±1.2 dB · 6 dB offset, Anritsu SC5237 POWER MONITOR MEASUREMENTS ·...
  • Page 6 Connect the MA2418A Reference Source · Open/Short, Anritsu 22N50 with the Attenuators to the input of the 560-7N50B RF Detector. · 50 Ohm Termination, Anritsu 26N50 Verify that the power monitor reading is · Source Adapter, Anritsu 34NN50A now –40.0 dBm ±2 dB.
  • Page 7 Figure 4. 541XXA Precision Return Loss Test Setup Press the Channel 1 Menu key. Procedure Using the Menu up-down keys: Highlight Connect the test equipment as shown in PRECISION RL, then press the Select Figure 4. key. Press the Power key on the 541XXA to At the PRECISION RETURN LOSS menu display, use the Menu up-down Press the System Menu key.
  • Page 8 When the calibration is complete, remove 1 : P R E C S N R L ( A ) 1 0 . 0 d B / D I V O . . S E T + 0 . 0 d B the 50 Ohm Termination.
  • Page 9 Detail A 7 (4 Places) Raised Wedge 2 (4 Places) 1 (4 Places) Figure 7. Sitemaster Battery Removal Remove the bottom half (5) and fold it over to BATTERY PACK REMOVAL lay upside down on the work surface. This procedure provides instructions for removing Disconnect the battery connector from J6 (6) the battery pack.
  • Page 10 If you do not have access to proper disposal methods, return the battery pack to your Anritsu service center. Service centers will dispose of the unit at no charge. Anritsu service centers are listed in Table 2 on page 11. Site Master MM...
  • Page 11 LCD REPLACEMENT MAIN RF PCB ASSEMBLY REPLACEMENT This procedure provides instructions for replacing the Liquid Crystal Display (LCD). Refer to Figure 7 This procedure provides instructions for replacing (page 8) during the procedure. the main RF PCB. Refer to Figure 7 (page 8) during this procedure.
  • Page 12 Remove the three screws holding the main REPLACEABLE PARTS RF PCB assembly to the test port panel. Replaceable parts for the Site Master are listed in NOTE Table 1 on page 12. Take care to not lose the mylar pad under Q5.
  • Page 13 Table 1. Parts List Part Number Description Part Number Description Main PCB Assy, S331A with RF Accessories ND45304 cable (Serial No. 707XXX and later) User's Guide, Site Master 10580-00005 S110, S111, S330, S331 Main PCB Assy, S330A with RF ND44171 cable (Serial No.
  • Page 14 Table 2. Anritsu Service Centers UNITED STATES FRANCE KOREA ANRITSU COMPANY ANRITSU S.A ANRITSU CORPORATION LTD. 685 Jarvis Drive 9 Avenue du Quebec #901 Daeo Bldg. 26-5 Morgan Hill, CA 95037-2809 Zone de Courtaboeuf Yeoido Dong, Youngdeungpo Telephone: (408) 776-8300...
  • Page 15 NOTES Site Master MM...