Device and controls
![]()
- Individually adjustable non-slip hand strap
- 3 × 2 rotating massage rollers
- Mains adaptor socket
- Sliding switch:
0 = device off
1 = low speed
2 = high speed
Items supplied and packaging
Please check first of all that the device is complete and is not damaged in any way. In case of doubt, do not use it and contact your dealer or your service centre.
The following parts are included:
- AC 850 - device
- mains adapter
- instruction manual
The packaging can be reused or recycled. Please dispose properly of any packaging material no longer required. If you notice any transport damage during unpacking, please contact your dealer without delay.
![]()
Please ensure that polythene packing is kept away from the reach of children! Risk of suffocation!
Cellulite massager AC 850
- Cellulite, an irregularity in the texture of the skin, is caused by an uneven distribution of subcutaneous fat, compression of the connective tissue and poor blood circulation.
- There is no magic cure for cellulite. Gymnastics, sport, a balanced diet and massages to encourage better circulation do, however, make the fat deposits melt away. They stimulate the metabolism, boost the lymphatic circulation and have a positive effect on the connective tissue.
- The cellulite massager provides a way to massage the buttocks, upper thighs, upper arms and hips to stimulate circulation. The massages have the welcome effect of activating and stimulating circulation – helping to activate the metabolism accordingly. The massage can, when performed on a daily basis and over a longer period of time, help to tauten the skin appreciably.
Operating the unit
- Plug the mains adapter into the socket
of the appliance and then plug the mains adapter into the power socket. - Hold the massager on the part of the body you wish to massage. Make sure that no parts of the body (e.g. fingers) or the power cable become trapped between the rotating massage rollers.
- If you feel any pain or using the appliance triggers unpleasant sensations, change the contact pressure, try a different part of the body, or discontinue the massage.
- Using the sliding switch
to activate the appliance. As soon as you push the switch to position 1, the massage rollers
start to rotate at a gentle speed. Select position 2. To switch the appliance off, push the sliding switch
to position 0.
NOTE
Uninterrupted treatment should not last longer than 15 minutes. Using the unit for longer can over-stimulate the muscles and cause tension.
Cleaning and maintenance
- Always pull the mains adapter out of the socket in the case of an electrical unit.
- Never use strong cleaning agents or stiff brushes.
- The massage rollers can be removed py pulling firmly and be cleaned under running water with a washing-up liquid. Dry off the rollers and place the appliance back on the base unit.
- Clean the unit with a soft cloth which has been lightly moistened with a mild soap. Never dip the unit into water for cleaning and ensure that no water gets into the unit at any time. Only use the unit again, when it is fully dry.
- Store the device in a dry, cool place.
Technical specifications
Name and model | MEDISANA Cellulite massager AC 850 |
Current supply | Mains adapter type: RSS1001-144120-W2E input: 100 - 240 V~; 50 - 60 Hz; 400 mA output: 12,0 V ⎓; 1200 mA |
Dimensions | appr. 130 x 110 x 85 mm (L x W x H) |
Weight | appr. 220 g (without mains adapter) |
Article no. | 88540 |
EAN-Number | 40 15588 88540 2 |
![]()
RETAIN FOR FUTURE USE!
Read the instruction manual carefully before using this device, especially the safety instructions, and keep the instruction manual for future use.
Should you give this device to another person, it is vital that you also pass on these instructions for use.
- Only use this unit according to the intended purpose and as directed in the instruction manual. The device is not intended for commercial use.
- Before connecting the device to your power supply, please ensure that the supply voltage stated on the rating plate is compatible with your mains supply.
- The warranty is null and void if it is not used for the intended purpose.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
- Children must be supervised to ensure that they do not play with the device.
- Do not attempt to repair the unit yourself in the event of any defects. Not only does this render the warranty null and void but you can also run the risk of serious hazards (fire, electric shock, injury). Only have repairs carried out by authorised service points.
- Cleaning and user maintenance shall not be made by children without supervision.
![]()
Use of the massage device is prohibited in the following cases:
- on children,
- on animals,
- you are pregnant,
- on the head and the throat,
- do not treat any parts of the body that have swellings, burns, inflammation, peeling skin, wounds or other sensitive points,
- people fitted with a pacemaker, artificial joints or electronic implants should in all cases consult a doctor before using the device,
- not while ingesting substances that reduce reaction times (e.g. painkiller medications, alcohol),
- you should not use this device if you are affected by one or more of the following illnesses and conditions: Circulation disorders, varicose veins, open wounds, bruises, broken skin, inflammation of the veins or thrombosis.
Please note the following in particular concerning electrical equipment:
- Only use the unit in enclosed spaces!
- Do not use any electrical equipment while in the bath or shower. Do not store or keep any electrical equipment in places where it could fall into the bathtub or washbasin.
- Do not reach for the unit if it has fallen into water. Disconnect the mains adapter from the mains socket immediately.
- Do not use the device in the vicinity of aerosol vapour or at the same time as an oxygen device.
- Do not use the device underneath bedding or cushions.
- Keep the mains cable away from hot surfaces and naked flames.
- Never use the unit if the power cable has been damaged, the mains adapter is defective, if the unit does not work perfectly, if it has fallen into water or has been damage.
- If the power supply cable, respectively the mains adaptor is damaged, it may only be replaced by MEDISANA, an authorised dealer or by qualified personnel.
- Never carry, pull or rotate the unit by the mains cable and never pinch or crush the cable between other objects.
- Keep the power cable away from the rotating massage rollers.
- Uninterrupted treatment should not last longer than 15 minutes. Then switch off the unit for at least half an hour and allow it to cool down.
- If you place too much strain on the appliance, it will be switched off by a thermal fuse. Then let the appliance cool down for at least 30 minutes before using it again.
- Only pull the plug out of the socket when you have dry hands, when the unit has been switched off and is not being used any longer, and also do this when you have to replace or clean the heads.
Important recommendations concerning your health
- Consult your doctor first before using this unit if you have diabetes or other related illnesses.
- The treatment should be pleasant. Stop at once and consult your doctor if you feel pain or the treatment seems unpleasant.
- Massages using the cellulite massager are not a substitute for treatments administered by doctors or physiotherapists.
MEDISANA GmbH
Jagenbergstraße 19
41468 NEUSS
GERMANY
E-Mail: info@medisana.de
Internet: www.medisana.com
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Need help?
Do you have a question about the AC 850 and is the answer not in the manual?
Questions and answers