  • Page 1 ® Z-2000 OW N ER ’S MANUAL A I R P UR I FI ER, MED IUM...
  • Page 2 ® Welcome to clean air with TruSens. Thank you for allowing us to join you on your journey towards wellness. The air you breathe should be clean, no matter where you are in the room. TruSens SensorPod™, PureDirect™ Technology & DuPont™ Filtration ensure the whole room...
  • Page 3: Table Of Contents

    CO NTEN TS SAFETY INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FEATURE HIGHLIGHTS .
  • Page 4: Safety Information

    SAFETY INFORMATION READ AND SAVE THESE INSTRUCTIONS/READ LABEL • Remove all packaging, including the filter bag, before use. AND OPERATING MANUAL BEFORE USING • Appliances that are obviously damaged must not be operated. PRECAUTIONS • This appliance must only be connected to a wall socket This appliance has a polarized plug (one blade is wider than outlet matching the supply plug type and rating stated on the other).
  • Page 5 Z-2000: or more of the following measures: FCC ID: GV3-22Z2000 IC: 6128A-22Z2000 •...
  • Page 6: Feature Highlights

    FEATURE HIGHLIGHTS SensorPod™ Remote air quality monitor that ensures cleaner air, right where you need it. PureDirect™ Technology Independent lab testing confirms that two airflow streams are better than one, moving air effectively and more comfortably throughout the room. Informs and Adapts Color-coded, illuminated ring provides additional information by communicating air quality in real time.
  • Page 7: Product Overview

    PRODUCT OVERVIEW Air Purifier Easy-carry handle Air quality indicator display Simple touch control panel 360° air intake Filter cover & knob (underneath) SensorPod Filter & UV-C Light ™ Power & signal Washable prefilter indicator Air outlet Carbon filter Power cord HEPA filter Air inlet UV-C light...
  • Page 8: Getting Started

    GETTING STARTED 1 . Remove plastic bag from filter Unscrew the bottom cover and remove the plastic bag from the filter. 2 . Reattach filter Secure filter on the bottom cover and replace inside the purifier.
  • Page 9 3 . Set up Plug in your SensorPod , and place upright on tabletop or counter across the ™ room, within line of sight of the purifier. Plug in your air purifier unit and power on. Place the purifier on a flat surface, free from obstructions.
  • Page 10: Control Panel

    CONTROL PANEL Timer Mode Power Button Purifier will automatically turn off after 2, 4, 8 or 12 hours. To cancel this countdown, simply press button until no timer setting is displayed. Fan Speed Settings Select fan speed or AUTO mode. In AUTO mode, UV Mode purifier automatically adjusts fan speed based on air UV bulb within the purifier’s filter chamber is on when...
  • Page 11: Air Quality Display

    In AUTO mode, the purifier automatically adjusts the fan speed in response to these air quality readings. GOOD MODERATE POOR BLUE | 0 - 50 YELLOW | 50 - 100 RED | 100 - 500 TruSens utilizes the Air Quality Index (1-500) created by the U.S. Environmental Protection Agency (EPA).
  • Page 12: Specifications

    SPECIFICATIONS Air Inlet 360° 375 ft² (35 m²) Room size at 2 ACH (air changes per hour) Air Delivery Type PureDirect ™ SensorPod ™ , works up to 49 ft (15 m) from purifier Sensor Fan Speed Settings Whisper, 1, 2, Turbo, AUTO Purification Levels Washable Prefilter, Carbon, HEPA, UV-C Light Timer Settings...
  • Page 13: Care & Maintenance

    CARE & MAINTENANCE WARNING: Always power off the purifier by pressing the Power Button and unplugging the power cord. To access the filter chamber, carefully remove the filter cover so Fig. A that the filter chamber is exposed (Fig. A). REPLACING HEPA DRUM FILTER The HEPA indicator will glow red when it is time to change the entire HEPA drum filter.
  • Page 14: Replacing The Standard Carbon Filter

    REPLACING THE STANDARD CARBON FILTER The Carbon indicator will glow red when it is time to replace the Carbon layer. 1. Gently peel away the Prefilter from the fastener strips (Fig. E). 2. Gently peel away the used Carbon layer from the fastener strips (Fig. F). Fig.
  • Page 15: Replacing Uv Bulb

    REPLACING UV BULB 1. The indicator will glow red when it is time to 4. Release carriage from the UV bulb (Fig. L). replace the UV bulb. 5. Secure carriage to new UV bulb (page 12) 2. Remove HEPA filter drum (Fig. A) and use a (Fig.
  • Page 16: Cleaning The Sensorpod

    CLEANING THE SENSORPOD ™ Cleaning the air quality sensor The SensorPod uses an infrared light to detect ™ particulate matter, so it is important that you clean the viewing chamber every 1-2 months to remove any dust or particles that may affect the accuracy of the sensor’s readings.
  • Page 17: Faq & Troubleshooting

    FAQ & TROUBLESHOOTING Where do I place the SensorPod Anywhere you want to measure the air quality within the room. For optimal ™ results, place the SensorPod up to 49 ft (15 m) away from the air purifier on a counter or table within line of sight of the purifier.
  • Page 18 FAQ & TROUBLESHOOTING Purifier won’t go into Auto Mode . First, check that the SensorPod is plugged in and that its light is solid. Next, check that the SensorPod is within range of the purifier (up to 49 ft/15 m). Air quality indicators are off .
  • Page 19: Warranty & Support

    TruSens machine. Any damage to or malfunction of your air purifier resulting from the use of non TruSens filters or UV bulbs may not be covered by this warranty or may result in a service fee if the damage or malfunction is determined to be caused by such use.
  • Page 20 .trusens .com ACCO Brands 101 O’Neil Road ©2024 ACCO Brands. All rights reserved. TruSens ® ® & Design, Sidney, NY 13838 SensorPod™ and PureDirect™ are trademarks of ACCO Brands. DuPont™ Tel: 1-833-TRUSENS & the Oval logo are trademarks or registered trademarks of E.I. du Pont de (1-833-878-7367) Nemours and Company used under license.