Delfield F18BC Service And Installation Manual

Delfield F18BC Service And Installation Manual

F18 series refrigerated work tables, salad tables & freezer bases

Advertisement

Cu s to m Sy s te m s
F18 SERIES
Service and Installation Manual
Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all
components immediately. See page 2.
Refrigerated Work Tables, Salad Tables & Freezer Bases
Effective Date December 2007

Advertisement

Table of Contents
loading

Summary of Contents for Delfield F18BC

  • Page 1 Service and Installation Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately. See page 2. Refrigerated Work Tables, Salad Tables & Freezer Bases Effective Date December 2007...
  • Page 2: Table Of Contents

    Check the lower portion of the unit to be sure legs or casters are not bent. For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com Serial Number Location The serial number on all self-contained F18 Series refriger-...
  • Page 3: Specifications

    VOLTS/HERTZ/ PANS HORSE POWER PHASE 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 115/60/1 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com EVAP. CAP. AMPS LOAD BTU/°TD 1050 1131 AMPS LOAD SYSTEM 1462 1462 1462 1462 10.0...
  • Page 4 21.30 A 5-15P NEMA plug is used on F18RC52, F18RC60 & F18RC68 . A 5-20P NEMA plug is used on , F18RC82, F18RC91, & F18RC99. For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com SHELF AREA # OF...
  • Page 5 PHASE 2.56 115/60/1 5.12 115/60/1 6.51 115/60/1 115/60/1 9.64 115/60/1 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com F18 Series Service and Installation Manual BTU DESIGN LOAD EVAP. CAP. PHASE AMPS BASE/RAIL 115/60/1 547/441 115/60/1 625/529...
  • Page 6: Installation

    For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com container. A refrigerated rail will have a 1" drain which will need to be run to an appropriate floor drain or container.
  • Page 7: Care And Cleaning

    Preventing blower coil corrosion To help prevent corrosion of the blower coil, store all acidic items, such as pickles and tomatoes, in sealable containers. Immediately wipe up all spills of items. For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com...
  • Page 8 3516273 valve, expansion, 1/4, hi, R-404A 3516103 3516102 2194536 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com XMK00107 EVAPORATOR COIL ASSEMBLY Coil assembly is standard with above parts, less solenoid coil, solenoid valve DESCRIPTION and thermostat.
  • Page 9: Mullion Coil Assembly (Freezer)

    Used on: F18FC and F18FR NOTE: Non-numbered items with ”‡” not sold separately — available only with com- plete assembly — XMK00061. For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com F18 Series Service and Installation Manual ‡...
  • Page 10 3 High-Mark 7 Refrigerated Drawer Assembly (32” Shown) For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com 6 11 See page 13 for part numbers. See page 13 for part numbers. See page 13 for part numbers.
  • Page 11: Cartridge Style Drawer Systems

    000-328-0031 000-328-0030 000-328-0037 000-328-0036 000-328-0035 000-328-0034 000-327-0033 000-327-0032 000-327-0031 000-327-0030 For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com F18 Series Service and Installation Manual Divider Intermediate Intermediate Bar(s) Left Track 264-018-0032, 264-018-0034 3234504 264-018-0033 3234517 264-018-0036, 264-018-0037...
  • Page 12: Door Assembly: Low Profile

    F18 Series Service and Installation Manual Door Assembly: Low Profile For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com Low Profile Used on: F18SC, F18SR, F18MC & F18MR NOTE: Indicate if door is left or right hinged when ordering.
  • Page 13: Door Assembly: Mark 7

    Used on: F18SC, F18SR, F18MC, F18MR, F18DC, F18DR, F18RC & F18RR NOT SHOWN - Clip on style louver Used on: F18FC, F18WR, For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com F18 Series Service and Installation Manual DELFIELD PART#...
  • Page 14 XMK00004 32” Door Assembly XMK00109 Evaporator Coil Assembly XMK00120 Complete Louver Assembly 3977983 Wire shelf 32” For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com F18DC91 000-402-0041 Removable hinged 10 pan cover 000-402-0045 Removable hinged 12 pan cover XMK00001 19”...
  • Page 15 F18MR52E 000-402-003K 18-pan hinged removable cover XMK00005 19” Lo Profile Door Assembly XMK00007 27” Lo Profile Door Assembly For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com F18 Series Service and Installation Manual F18RC SERIES STANDARD PARTS...
  • Page 16 3516225 Expansion valve 9321041 Chrome plated acorn nut 9321136 Holding for cutting board pin 9321374 Salad pan cover pin hinge For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com ADDITIONAL PARTS F18SC39A SERIES 000-402-003T Removable 6-pan hinged cover XMK00005 19”...
  • Page 17 XMK00108 Evaporator Coil Assembly 3977984 Wire Shelf 19” 3978014 Wire Shelf 27” Delfield ™ ® F18WR87 SERIES XMK00003 Door assembly 27” 3978014 Wire Shelf 27” For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com F18 Series Service and Installation Manual...
  • Page 18: Wiring Diagrams

    F18MC, F18SC, F18BC & F18RC ON/OFF SWITCH BASE SWITCH RAIL For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com ON 115 VOLT MODELS ONLY L2 IS THE NEUTRAL CONDENSING UNIT EVAPORATOR FAN(S) ON 115 VOLT MODELS ONLY...
  • Page 19 Delfield ™ ® CONDENSING UNIT BLACK/ ORANGE PRESS SWITCH PURPLE ORANGE EVAP FANS WHITE DEFROST HEATER DOOR FRAME HEATER MULLION HEATER For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com F18 Series Service and Installation Manual DELAY...
  • Page 20: Warranties

    (1) year from the date of installation. During this one year warranty period, Delfield will repair or replace any defec- tive part or portion there of returned to Delfield by the Original Purchaser which Delfield determines was defective due to faulty material or workmanship.
  • Page 21 Unit manufacturer, repaired or altered by anyone other than Delfield in any way so as, in Delfield’s sole judgment, to affect its quality or efficiency or if the serial number has been altered, defaced or removed.
  • Page 22: Authorized Parts Depots

    980 S. Isabella Rd., Mt. Pleasant, MI 48858, U.S.A. • +1(989) 773-7981 or (800) 733-8829 • Fax (866) 779-2040 • www.delfield.com Delfield reserves the right to make changes in design or specifications without prior notice. 2001 the Delfield company. All rights reserved. Printed in the U.S.A.