Delfield IMPORTANT WARNING AND SAFETY INFORMATION WARNING Read this manual thoroughly before operating, installing, or performing maintenance on the equipment. FAILURE TO FOLLOW INSTRUCTIONS IN THIS MANUAL CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
SAFETY PRECAUTIONS... 2 INTRODUCTION ... 5 General ... 5 Heating System ... 5 Refrigeration System ... 5 Freezer Refrigeration System ... 5 Dual Temperature Refrigeration/Freezer ... 5 SERIAL NUMBER ... 6 RECEIVING AND INSPECTING THE EQUIPMENT ... 6 SPECIFICATIONS ... 7 INSTALLATION ...
Page 4
Delfield Table of Contents – Continued ROLL-INS AND ROLL-THRUS ... 18 Location ... 18 Inside Cabinet ... 18 Outside Cabinet ... 18 Leveling ... 19 Stabilizing... 19 Electrical Connection ... 19 OPERATION INFORMATION ... 19 HEATED MODELS ... 19 REFRIGERATION MODELS ... 20 OPTIONAL ERC CONTROL ...
27°F and 44°F in heavy use food service operations. Refrigerant is me- tered using a highly responsive thermostatic expansion valve. System is controlled using Delfield’s ACT-Ad- vanced Control Technology electronic temperature con- trol, which provides improved pull down times, reducing compressor cycling and longer compressor life with lower energy consumption.
On heated units, the identification plate is located in the shroud area on the right side panel. For parts and services go to www.delfield.com. RECEIVING AND INSPECTING THE EQUIPMENT Care should be taken during unloading so the equipment is not damaged while being moved into the building.
SPECIFICATIONS MODEL VOLTAGE NUMBER SSHRT1-S, SAHRT1-S 120/208-240 SSHRT2-S, SAHRT2-S 120/208-240 SSHRT3-S, SAHRT3-S 120/208-240 SSHRT1-GS, SAHRT1-GS 120/208-240 SSHRT2-GS, SAHRT2-GS 120/208-240 SSHRT3-GS, SAHRT3-GS 120/208-240 SOLID DOOR HOT FOOD CABINET REACH-IN MODEL VOLTAGE NUMBER SSH1-S, SSH1-SH, SAH1I-S, SAH1-SH 120/208-240 SSH2-S, SSH2-SH, SAH2-S, SAH2-SH 120/208-240 SSH3-S, SSH3-SH, SAH3-S, SAH3-SH...
Page 8
Delfield SOLID DOOR NARROW HOT FOOD CABINET REACH-IN MODEL VOLTAGE NUMBER SSH2N-S SAH2N-S 115/208-240 GLASS DOOR HOT FOOD CABINET REACH-IN MODEL VOLTAGE NUMBER SSH1-G, SSH1-GH, SAH1-G, SAH1-GH, 115/208-240 SSH2-G, SSH2-GH, SAH2-G, SAH2-GH 115/208-240 SSH3-G, SSH3-GH, SAH3G, SAH3GH 115/208-240 SELF CONTAINED SOLID DOOR WINE CABINET REACH-IN...
Page 9
SELF CONTAINED SHALLOW SOLID DOOR REACH-IN REFRIGERATOR MODEL VOLTAGE NUMBER SSR1S-S, SSR1S-SH, SAR1S-S, SAR1S-SH SSR2S-S, SSR2S-SH, SAR2S-S, SAR2S-SH SSR3S-S, SSR3S-SH, SAR3S-S, SAR3S-SH SELF CONTAINED SHALLOW HINGED GLASS DOOR REACH-IN REFRIGERATOR MODEL VOLTAGE NUMBER SSR1S-G, SSR1S-GH, SAR1S-G, SAR1S-GH SSR2S-G, SSR2S-GH, SAR2S-G, SAR2S-GH SSR3S-G, SSR3S-GH, SAR3S-G, SAR3S-GH SELF CONTAINED SOLID DOOR ROLL-THRU REFRIGERATOR...
Page 10
Delfield SELF CONTAINED HINGED GLASS DOOR PASS-THRU REFRIGERATOR MODEL VOLTAGE NUMBER SSRPT1-G, SSRPT1-GH, SARPT1-G, SARPT-GH SSRPT2-G, SSRPT2-GH, SARPT2-G, SARPT2-GH SSRPT3-G, SSRPT3-GH, SARPT3-G, SARPT3-GH 115/208-230 SELF CONTAINED SOLID DOOR ROLL-IN REFRIGERATOR MODEL VOLTAGE NUMBER SSRRL1-S, SARRL1-S SSRRL2-S, SARRL2-S SSRRL3-S, SARRL3-S 115/208-230...
Page 11
SELF CONTAINED NARROW HINGED GLASS DOOR REACH-IN REFRIGERATOR MODEL VOLTAGE NUMBER SSR1N-G, SSR1N-GH, SAR1N-G, SAR1N-GH SSR2N-G, SSR2N-GH, SAR21N-G, SAR21N-GH SELF CONTAINED SOLID DOOR PASS-THRU REFRIGERATOR MODEL VOLTAGE NUMBER SSRPT1, SARPTS SSRPT2, SARPT2 SSRPT3, SARPT3 SELF CONTAINED SOLID DOOR PASS-THRU REFRIGERATOR MODEL VOLTAGE NUMBER...
Page 12
SELF CONTAINED SLIDING DOOR SHALLOW REACH-IN REFRIGERATOR MODEL VOLTAGE NUMBER SSR2S-SL, SAR2S-SL SELF CONTAINED SLIDING DOOR REACH-IN REFRIGERATOR MODEL VOLTAGE NUMBER SSR2-SL, SAR2-SL SELF CONTAINED SHALLOW SOLID DOOR REACH-IN FREEZER MODEL VOLTAGE NUMBER SSF1S-S, SSF1S-SH, SAF1S-S, SAF1S-SH SSF2S-S, SSF2S-SH, SAF2S-S, SAF2S-SH SSF3S-S, SSF3S-SH, SAF3S-S, SAF3S-SH...
Page 13
DESCRIPTION VOLTAGE NUMBER SSDRLPT2, LEFT DR REF SADRLPT2 RIGHT DR FRZ SSDFLPT2, LEFT DR FRZ SADFLPT2 RIGHT DR REF GLASS DOOR SINGLE SECTION DUAL TEMP REFRIGERATOR/FREEZER REACH-INS MODEL VOLTAGE AMPS NUMBER SSDTR1-GH/ SADTR1-GH Refrigerator 115/60/1 14 TOTAL Freezer 115/60/1 SSDBR1-GH/ SADBR1-GH...
Page 14
Delfield SOLID DOOR SINGLE SECTION DUAL TEMP REFRIGERATOR/FREEZER MODEL VOLTAGE NUMBER SSDTPT1-SH/ SADTPT1-SH Refrigerator 115/60/1 14 TOTAL Freezer 115/60/1 SSDBT1-SH/ SADPT1-SH Freezer 115/60/1 Refrigerator 115/60/1 SELF CONTAINED SOLID DOOR PASS-THRU FREEZER MODEL VOLTAGE NUMBER SSFPT1, SAFPT1 SSFPT2, SAFPT2 115/208-230 SSFPT3, SAFPT3...
Page 15
SOLID DOOR SINGLE SECTION DUAL TEMP REFRIGERATOR/FREEZER REACH-INS MODEL VOLTAGE AMPS NUMBER SDTR1-SH/ SADTR1-SH Refrigerator 115/60/1 14 TOTAL Freezer 115/60/1 SDBR1-SH/ SADBR1-SH Freezer 115/60/1 14 TOTAL Refrigerator 115/60/1 SELF CONTAINED HINGED GLASS DOOR REACH-IN FREEZER MODEL VOLTAGE NUMBER SSF1-G, SSF1-GH,...
Page 16
Delfield SELF CONTAINED SOLID DOOR CONVERT-A-TEMP REACH-IN MODEL VOLTAGE NUMBER SSR1-S, SAR1-S SSR2-S, SAR2-S GLASS DOOR SINGLE SECTION DUAL TEMP REFRIGERATOR/FREEZER MODEL VOLTAGE NUMBER SSDTPT1-GH/ SADTPT1-GH Refrigerator 115/60/1 14 TOTAL Freezer 115/60/1 SSDBPT1-GH/ SADBPT1-GH Freezer 115/60/1 14 TOTAL Refrigerator 115/60/1...
INSTALLATION REACH-INS AND PASS-THRUS Location Cabinets represented in this manual are intended for indoor use only. Be sure the location chosen has a floor strong enough to support the total weight of the cabinet, 1000 lbs. per door section. Reinforce the floor if necessary to provide for maximum loading.
Delfield Stabilizing It is very important that all legs are properly adjusted to keep the cabinet level, evenly distribute the weight and to make sure the unit will not rock, lean or be unstable. Electrical Connection DANGER Refer to the amperage data list in the SPECIFICA-...
Leveling After the cabinet has been placed in the desired location, cabinets with legs must be leveled. Level units from front to back and from side to side. Leveling will insure proper door operation and removal of condensate. Cabinets with casters must have the caster brake set so the cabinet cannot move.
Refrigerated wine cabinet units have a POWER ON/OFF switch located on the front of the unit for controlling power to the unit and a Delfield’s ACT-Advanced Control Tech- nology electronic temperature control for setting the temperature. The temperature control holds the tem- perature between 50°F and 60°F and provides improved...
Page 21
Refrigerated cabinet units have a POWER ON/OFF switch located on the front of the unit for controlling power to the unit and a Delfield’s ACT-Advanced Control Tech- nology electronic temperature control for setting the temperature. The temperature control holds the tem- perature between 27°F and 44°F and provides improved...
6. Clean equipment as discussed in the mainte- nance section of this manual. CONVERT-A-TEMP This unit can be used as either a refrigerator or a freezer. A key switch located behind the hinged upper shroud performs conversion. A master POWER ON/OFF switch controls power to the unit.
-40°F to 122°F; 0 to 95% RH Agency Certifications: UL, CSA, NSF Special Features The default parameters for Delfield will be pre-programmed. In case of a power failure, the control has a safe operating mode in case of sensor failure.
Figure 7. ERC Control Panel For more information on the ERC Control, please log onto our web site at www.delfield.com and go to the parts and service section, then to the service department page. Press and hold SET for 5 seconds. The display will show CLoC Press SET again to change the time of day.
Continue turning until the correct time of day on the outer dial lines up with the time pointer. This operation requires an initial start-up and any time thereafter when there is an interruption of power to the freezer. Operation The Paragon 8145 timer is preset at the factory to provide four defrosts per day at six-hour intervals starting at 6:00 am.
Delfield Operation The electric defrost controller is preset at the factory to provide a defrost cycle every 6 hours (4 defrost per day). If it is necessary to change the number of defrosts due to unusual conditions, it can be accomplished by adjusting the Cycle time switches, see Figure 9.
STANDARD LABOR GUIDELINES TO REPAIR OR REPLACE PARTS ON DELFIELD EQUIPMENT Advice and recommendations given by Delfield Service Technicians do not constitute or guarantee any special coverage. A maximum of 1-hour is allowed to diagnose a defective component. A maximum of 1-hour is allowed for retrieval of parts not in stock.
Unit or any exhaust system. Delfield shall not be liable in any manner for any default or delay in performance hereunder caused by or resulting from any contingency beyond Delfield’s control, including, but not limited to, war, govern-...
(for motor-compressor only) General Conditions Delfield shall not be liable in any manner for any default or delay in performance hereunder caused by or resulting from any contingency beyond Delfield’s control, including, but not limited to, war, governmental restrictions or restraints, strike,...