    1. Safety Warnings This  instrument  has  been  designed and  tested according  to  IEC  Publication  61010: Safety  Requirements  for  Electronic  Measuring  Apparatus.  This  instruction  manual contains warnings and safety rules which must be observed by the user to ensure safe operation  of  the  instrument  and  to  retain  it  in  safe  condition.  Therefore,  read  through these operating instructions before starting using the instrument. WARNING ●Read  through  and  understand  instructions  contained  in  this  manual  before  starting to use the instrument.
  • Page 3: Specification

    3. Specification AC current 〜A Accuracy CF(Crest factor) Measuring range Range ±2.0%rdg±5dgt(50/60Hz) CF≦2 0〜100A ±3.0%rdg±5dgt(50/60Hz) 2<CF≦2.5 DC current  Range Measuring range Accuracy 0〜±100A ±2.0%rdg±5dgt AC voltage 〜V Action Range Measuring range AC300V or less Normal condition : Lo At voltage detecting(single wire AC80V or more) : Hi Note) NCV  range  is  calibrated  to  detect  the  voltage,  where  non-grounded  single  wire, AC80V  or  more.  However,  detecting  sensitivity  may  be  affected  by  the  absence  of grounded or non-grounded metal tube or metal case. Also it may be affected in the place ...
  • Page 4: Instrument Layout

    Reference *Effective Value (RMS) Most alternating currents and voltages are expressed in effective values, which are also referred to as RMS (Root-Mean-Square) values. The effective value is the square root of the average of square  of  alternating  current  or  voltage  values.  Many  clamp  meters  using  a  conventional rectifying  circuit  have  "RMS"  scales  for  AC  measurement.  The  scales  are,  however,  actually calibrated in terms of the effective value of a sine wave though the clamp meter is responding to the average value. The calibration is done with a conversion factor of 1.111 for sine wave, which is found by dividing the effective value by the average value. These instruments are therefore in error if the input voltage or current has some other shape than sine wave. *CF (Crest Factor) is found by dividing the peak value by the effective value. Examples: Sine wave: CF=1.414 Square wave with a 1: 4 duty ratio: CF=2 4. INSTRUMENT LAYOUT Function Selector Switch Display Fork Jaws Hand Strap...
  • Page 5 5. Preparation (1) Check battery voltage Set the Function selector switch to the position other than OFF position. Battery  Voltage  is  enough  if  indications  are  displayed  clearly  and  "BATT"  mark  is  not displayed on the LCD. If "BATT" mark is indicated or no indication on the LCD, replace batteries with new one according to battery replacement procedures shown in clause 8 in this document. CAUTION ●Indications may not being displayed on the LCD despite the function selector switch is at the position other than OFF position. This is because power-off function operated automatically and the instrument turned off. Power off function can be released by turning the function selector switch to OFF, and then set it to the range on which you would like to make a measurement. If LCD still blank, batteries are completely exhausted. Please replace batteries. (2) Check the function selector switch is set to the appropriate range. And also check data hold  function  is  not  enabled.  If  inappropriate  range  is  selected,  desired  measurement cannot be made.
  • Page 6 Note) For  the  measurement  of  AC  current,  zero  adjustment,  which  is  required  for  the measurement  of  DC  current,  is  not  necessary.  Current  flowing  direction  has  no relation to the indication polarity. 6-2 Non contact voltage detection(NCV) This function is to check the presence of voltage without touching wires or electrodes directly. Also can check the presence of AC voltage in cable, outlet, fuse and circuit breaker. [Details] While voltage is applied to a cable or outlet, the electric field depending on the voltage is  generated.  This  instrument  detects  the  generated  electric  field,  and  verifies  the presence ...
  • Page 7: Other Functions

    (1) 100V mode Sensitivity  on  this  mode  is  set  sharp,  therefore,  the  presence  of  AC  voltage  can  be checked  only  by  placing  the  instrument  closer  to  the  measured  object,  such  as  an outlet, a plug and parallel cords, as shown in figure. (2) 200V mode Sensitivity on this mode is set dull, so the earth side and non-earth side of 100V cable way can de verified. (Where cables are crowded, such as in a distribution board, earth side could not be verified.) Also can check the presence of AC voltage in 200V cable way, plug, outlet, fuse and circuit breaker. 7. Other functions 7-1 Auto power off function This  function  causes  the  instrument  to  automatically  enter  the  power-off  mode  about 10min after the last function selector switch operation.