  • Page 1 GP1100 Glass panic device - down latching dummy rail mount (use with exterior pull types A, B, C, F, G, H, K, KS, L, L, X, Z) Installation instructions 974-011 – 10-2020 | EN |...
  • Page 2: Table Of Contents

    GP1100 Dummy Rail Mount (for down latching) Table of Contents Installation Instructions Table of contents 1  Technical specifications Overview 1.1.1 General information 1.1.2 Intended use 1.1.3 Glass requirements/fittings/mounting 1.1.4 Requirements for glass panel 1.1.5 Safety instructions 1.1.6 Symbols used - Safety/Installation 1.1.7 Maintenance, care, repair...
  • Page 3: Technical Specifications

    GP1100 Dummy Rail Mount (for down latching) Technical specifications Installation Instructions 1  Technical specifications Overview These instructions are for installation of GP1100 Dummy Glass Panic Device for the following mounting and style versions: 1. Down latching rail mount Symbols used - Safety/Installation 1.1.6...
  • Page 4: Adhesive Specification

    GP1100 Dummy Rail Mount (for down latching) Technical specifications Installation Instructions Overall 1.1.9 Adhesive specification Table 1 Adhesive required for GP1100 (not included) Loctite® Threadlocker Handling description Time Blue 242® Set time (time between application and 10 minutes on active metals (steel) tightening of screw) Longer for less active metals.
  • Page 5: Mount Exterior Pull Components - Disassemble Actuator Parts

    GP1100 Dummy Rail Mount (for down latching) Actuator Installation Instructions Mount exterior pull components - disassemble actuator parts Fig 3 NOTE: PANIC DEVICE SHOULD BE MOUNTED TO DOOR IN A HORIZONTAL POSITION. LAY GLASS PANEL FLAT ON SAW HORSES AND MOUNT THE FOLLOWING EXTERIOR PULL COMPONENTS FIRST.
  • Page 6: Mount Exterior Pull Components - Top Standoff

    GP1100 Dummy Rail Mount (for down latching) Exterior pull - top standoff Installation Instructions Mount exterior pull components - top standoff Fig 4 Back-to-Back Pull Options top rail mount assembly Door side Pull type Interior Exterior F (shown) INTERIOR...
  • Page 7: Mount Exterior Pull Components - Bottom Standoff

    GP1100 Dummy Rail Mount (for down latching) Exterior pull - bottom standoff Installation Instructions Mount exterior pull components - bottom standoff Fig 5 Pull Options Door side Pull type Interior Exterior F (shown) INTERIOR Bottom rail mount components Back-to-Back bottom rail 2.4.1 Disassemble bottom rail mount exterior...
  • Page 8: Return Tube (D-Pull; Back-To-Back)

    GP1100 Dummy Rail Mount (for down latching) Exterior pull - back-to-back return tube Installation Instructions Mount exterior pull components - return tube (back-to-back) Fig 6 Pull Options Door side Pull type Interior INTERIOR Exterior C (shown) Back-to- Back glass mount 2.5.1 Disassemble return tube components.
  • Page 9: Mount Interior Pull Components - Dummy Actuator And Int. Pull

    GP1100 Dummy Rail Mount (for down latching) Interior pull - actuator Installation Instructions Mount interior pull components - dummy actuator and int. pull Fig 7 NOTE: FLIP DOOR OVER AND LAY FLAT ON SAW HORSES TO MOUNT THE INTERIOR SIDE COMPONENTS.
  • Page 10: Mount Interior Pull Components - Bottom Standoff

    GP1100 Dummy Rail Mount (for down latching) Interior pull - top standoff Installation Instructions Mount interior pull components - bottom standoff Fig 8 Single-sided mount Back-to-back mount Bottom rail Bottom rail mount mount components components 2.7.1 Disassemble bottom rail mount 2.7.1 Disassemble bottom rail mount...
  • Page 11: Mount Interior Pull Components - Return Tube (Single-Sided)

    GP1100 Dummy Rail Mount (for down latching) Interior pull - single-sided return tube Installation Instructions Mount interior pull components - return tube (single-sided) Fig 9 Pull Options Door side Pull type Interior INTERIOR Exterior none (Z) (shown) Interior rose assembly 2.8.1 Disassemble rose...
  • Page 12: Mount Interior Pull Components - Return Tube (Back-To-Back)

    GP1100 Dummy Rail Mount (for down latching) Interior pull - back-to-back return tube Installation Instructions Mount interior pull components - return tube (back-to-back) Fig 10 Pull Options Door side Pull type Interior Exterior C (shown) INTERIOR Back-to- Back glass...
  • Page 13: Adjustments

    GP1100 Dummy Rail Mount (for down latching) Adjustments: clearances Installation Instructions 3 Adjustments Clearances Fig 11 Glass Dummy Exterior Interior Pull Panic Rail 1/4” Floor 2” [51] ENSURE THE DISTANCE FROM THE FACE OF THE GLASS (F.O.G.) TO THE CENTERLINE OF THE INTERIOR PULL IS 2”...
  • Page 14: Final Adjustments (Tube Height Or Length)

    GP1100 Dummy Rail Mount (for down latching) Adjustments: tube height or length Installation Instructions Loctite Final adjustments (tube height or length) Fig 12 Interior Panic Tube shown Bottom section of tube Interior Panic Tube shown Return tube 3.2.1 Ensure interior and exterior tubes are at the 3.2.3 To adjust length of tube:...
  • Page 15 USA, Inc. 1 Dorma Drive, Drawer AC Reamstown, PA 17567 T: 717-336-3881 F: 717-336-2106 www.dormakaba.com...