Download Print this page
Dormakaba GP1000 Installation Instructions Manual
Dormakaba GP1000 Installation Instructions Manual

Dormakaba GP1000 Installation Instructions Manual

Glass panic device - top latching rail mount

Advertisement

Quick Links

GP1000
Glass panic device - top latching rail mount
(use with exterior pull types: A, B, D, F, G, H, J, JS, L, LS, X, Z)
Installation instructions
974002 – 10-2020
| EN |

Advertisement

loading
Need help?

Need help?

Do you have a question about the GP1000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Dormakaba GP1000

  • Page 1 GP1000 Glass panic device - top latching rail mount (use with exterior pull types: A, B, D, F, G, H, J, JS, L, LS, X, Z) Installation instructions 974002 – 10-2020 | EN |...
  • Page 2 GP1000 Top Latching Rail Mount Installation Instructions Table of Contents Table of contents 1  Technical specifications Overview 1.1.1 General information 1.1.2 Intended use 1.1.3 Glass requirements/fittings/mounting 1.1.4 Requirements for glass panel 1.1.5 Safety instructions 1.1.6 Symbols used - Safety/Installation 1.1.7 Maintenance, care, repair...
  • Page 3 GP1000 Top Latching Rail Mount Installation Instructions Technical specifications 1  Technical specifications Overview These instructions are for installation of GP1000 Glass Panic Device for the following mounting and style versions: 1. Top latching rail mount Symbols used - Safety/Installation 1.1.6...
  • Page 4 GP1000 Top Latching Rail Mount Installation Instructions Technical specifications Overall 1.1.9 Adhesive specification Table 1 Adhesive required for GP1000 (not included) Loctite® Threadlocker Handling description Time Blue 242® Set time (time between application and 10 minutes on active metals (steel) tightening of screw) Longer for less active metals.
  • Page 5 GP1000 Top Latching Rail Mount Installation Instructions Actuator Mount exterior pull components - actuator housing Fig 3 NOTE: PANIC DEVICE SHOULD BE MOUNTED TO DOOR IN A HORIZONTAL POSITION. LAY GLASS PANEL FLAT ON SAW HORSES AND MOUNT THE FOLLOWING EXTERIOR PULL COMPONENTS FIRST.
  • Page 6 GP1000 Top Latching Rail Mount Installation Instructions Exterior pull - top standoff Mount exterior pull components - top standoff Fig 4 Back-to-Back Pull Options top rail mount Door side Pull type assembly Interior Exterior F (shown) INTERIOR Top rail mount components 2.3.1 Disassemble top rail mount exterior pull...
  • Page 7 GP1000 Top Latching Rail Mount Installation Instructions Exterior pull - bottom standoff Mount exterior pull components - bottom standoff Fig 5 Pull Options Door side Pull type Interior Exterior F (shown) INTERIOR Bottom rail mount components Back-to-Back bottom rail 2.4.1 Disassemble bottom rail mount exterior...
  • Page 8 GP1000 Top Latching Rail Mount Installation Instructions Exterior pull - back-to-back return tube Mount exterior pull components - return tube (back-to-back) Fig 6 Pull Options Door side Pull type Interior INTERIOR Exterior D (shown) Back-to- Back glass mount 2.5.1 Disassemble return tube components.
  • Page 9 GP1000 Top Latching Rail Mount Installation Instructions Interior pull - actuator Mount interior pull components - actuator housing and int. pull Fig 7 NOTE: FLIP DOOR OVER AND LAY FLAT ON SAW HORSES TO MOUNT THE INTERIOR SIDE COMPONENTS.
  • Page 10 GP1000 Top Latching Rail Mount Installation Instructions Interior pull - top standoff Mount interior pull components - top standoff Fig 8 Back-to-back mount Single-sided mount Single-sided Back-to-Back top rail mount top rail mount assembly assembly INTERIOR INTERIOR Pull Options...
  • Page 11 GP1000 Top Latching Rail Mount Installation Instructions Interior pull - single-sided return tube Mount interior pull components - return tube (single-sided) Fig 9 Pull Options Door side Pull type Interior INTERIOR Interior rose Exterior none (Z) (shown) assembly 2.8.1 Disassemble rose and bushing from interior return tube.
  • Page 12 GP1000 Top Latching Rail Mount Installation Instructions Interior pull - back-to-back return tube Mount interior pull components - return tube (back-to-back) Fig 10 Pull Options Door side Pull type Interior Exterior D (shown) INTERIOR Back-to- Interior Back glass return...
  • Page 13 GP1000 Top Latching Rail Mount Installation Instructions Adjustments: clearances 3 Adjustments Clearances Fig 11 Shim Factory set for Strike 11/16” [17] Header Shim Header (top of roller to 3/16” top of interior panic tube) Strike Roller latch Rail Rail...
  • Page 14 GP1000 Top Latching Rail Mount Installation Instructions Adjustments: tube height or length Adjustments: roller latch Final adjustments (tube height or length) Fig 12 Interior Panic Tube shown Top section of tube Interior Panic Tube shown Return tube 3.2.1 Ensure interior and exterior tubes are at the 3.2.3 To adjust length of tube:...
  • Page 15 GP1000 Top Latching Rail Mount Installation Instructions Loctite part list Locking the panic Loctite part list GPII part Referenced step Actuator set screws * Step 2.2 Interior tube coupler set screw * Step 2.7.4 Interior return tube rose Step 2.8.4 Interior return tube set screw * Step 2.9.2...
  • Page 16 USA, Inc. 1 Dorma Drive, Drawer AC Reamstown, PA 17567 T: 717-336-3881 F: 717-336-2106 www.dormakaba.com...