Page 4
Content | Obsah | Treść | Tartalom | Conținut OR / UR Error codes | Chybové kódy | Kody błędów | Hibakódok | Coduri de eroare Troubleshooting | Řešení problémů | Rozwiązywanie problemów | Hibaelhárítás | Rezolvarea problemelor Changing Cuvette/Calibration | Výměna kyvety/kalibrace | Zmiana kuwety/kalibracja | Küvetták cseréje/kalibrálás | Schimbarea cuvei/Calibrare Accessories | Příslušenství...
Page 5
Delivery Content | Obsah dodávky | Treść dostawy | Szállítási tartalom | Conținutul livrării 01 x PoolLab 1.0 ® 01 x Light shield 03 x AAA Batteries 01 x Crushing | Stirring Rods 01 x 10 ml syringe 01 x User Manual 20 x Phenol Red Photometer tablets 20 x DPD N°...
Switch on/off | Zapnutí/vypnutí | Włączanie/wyłączanie | Be/ki kapcsoló | Pornire/oprire Seite 7 00:02 The On/Off button can also be used to skip countdown during measurement (not recommended). Tlačítko zapnutí/vypnutí lze také použít k přeskočení odpočítávání během měření (nedoporučuje se). Przycisk On/Off może być...
Notes | Poznámky | Uwagi | Megjegyzések | Note dness Total Hardness Total Hardness Total Hardness Total Hardness Total Hardness ardness Total Hardness Total Hardness Total Hardness ardness Total Hardness Total Hardness Total Hardness Total Hardness Total Hardness Hardness Total Hardness Total Hardness Total Hardness Total Hardness Total Hardness Total Hardness Total Hardness Total Hardness Total Hardness Hardness Total Hardness...
Important | Důležité | Ważne | Fontos | Important Detergent It is important to clean the device after each measurement to get rid of any reagent residues! Please ensure that the cuvette has been cleaned before each measurement (e.g. under clear water/or simply rinsing the cuvette in the pool is sufficient as long as no residues remain).
Page 10
Do not leave the device in the sun! Nenechávejte přístroj na slunci! Nie pozostawiać urządzenia na słońcu! Ne hagyja a készüléket a napon! Nu lăsați dispozitivul în soare! The PoolLab 1.0 is also suitable for saltwater pools/salt ® electrolysis pools! PoolLab 1.0 je vhodný...
Tablet Mode → Liquid Mode Režim tabletu → Tekutý režim Tryb tabletu → Tryb płynny Tablet üzemmód → Folyékony üzemmód Mod tabletă → Mod lichid pH | fCl | tCl | cCl | Br | ClO Scan the QR-code to watch our instruction video...
Page 12
Tablet Mode: TABLET TEST TEST MODE Liquid Mode: LIQUID TEST TEST MODE...
Page 13
From firmware version 72 onwards, you have the option of measuring the following parameters with tablets as well as with liquid reagents: pH, chlorine, chlorine dioxide, ozone and bromine. You can choose between two measurement settings in the unit: Tablets and Liquid reagents. You can switch between the modes by pressing and releasing the ZERO &...
Page 14
A 72-es firmware-verziótól kezdődően a következő lehetőségek állnak rendelkezésre a következő paraméterek mérése tablettákkal és folyékony reagensekkel: pH, klór, klór-dioxid, ózon és bróm. A készülékben két mérési beállítás közül választhat: Tabletták és folyékony reagensek. Az üzemmódok között a ZERO & On/Off gomb egyidejű megnyomásával és elengedésével válthat.
QUICK START GUIDE Stručný průvodce Skrócona instrukcja obsługi Gyorsindítási útmutató Ghid de pornire rapidă Scan the QR-code to watch our instruction video...
Page 16
3 x AAA 00:02 START: Take 10 ml Water Sample ZERO TEST...
Page 17
Remove Lightshield TEST TEST Reagent(s) for your test (refer to chapter in manual) Put on Lightshield TEST TEST Await Countdown Shortcut for your Test (Refer TEST result in PPM to chapter in manual)
Page 18
Empty & Clean For Next Test: Take 10 ml If Device was If Device was not switched off, start switched off, start from step 4 from step 7 Repeat Repeat steps steps 4-13 7-13 for further for further Parameters Parameters End Of Quick Start Guide | Konec stručné...
Page 20
Only one Time Per Test Batch | Pouze jednou na zkušební dávku | Tylko jeden raz na partię testową | Vizsgálati tételenként csak egy alkalommal | O singură dată per lot de testare The „ZERO“ step (page 19) is only necessary once after switching on.
Active Oxygen (MPS) Aktivní kyslík (MPS) Aktywny tlen (MPS) Aktív oxigén (MPS) Oxigen activ (MPS) 0.0 – 30.0 ppm (mg/l) DPD N°4 Photometer* *not part of Standard Equipment Take 10 ml Water Sample...
Page 22
1 x DPD N°4 ZERO! (p. 19) Photometer* Completely Dissolved Residue TEST ZERO TEST TEST 12.2 ppm...
Bromine Brom Brom Bróm Brom Tablet Mode: Liquid Mode: 0.00 – 18.00 ppm (mg/l) 0.00 – 9.00 ppm (mg/l) DPD N°1 Photometer Tablet + DPD 1B Liquid* Glycine* Glycine* *not part of Standard Equipment ZERO! (p. 19) Take 10 ml Water Sample ZERO...
Page 26
Only if your water sample does contain Chlorine next to Bromine (both disinfectants used), the following procedure „A“ needs to be followed and Glycine* reagent needs to be used. Otherwise (only Bromine present), please follow procedure „B“. Pouze v případě, že váš vzorek vody obsahuje vedle bromu i chlor (obě...
Page 27
With Chlorine | S chlorem | Z chlorem | Klórral | Cu clor Glycine* Completely Dissolved TEST TEST Residue Tablet or Liquid? (p. 11) Completely Dissolved DPD N°1 TEST TEST Photometer Residue...
Page 28
Without Chlorine | Bez chlóru | Bez chloru | Klór nélkül | Fără clor Tablet or Liquid? (p. 11) Completely Dissolved TEST TEST DPD N°1 Residue Photometer 8a / 6 TEST 6.00 ppm...
Page 36
1.65 ppm Total Chlorine is measured directly after free Chlorine without emptying the cuvette. The DPD N°3 tablet is added to the sample water which already contains the DPD N°1 tablet (dissolved). Combined Chlorine is calculated as Total Chlorine minus free Chlorine. The free chlorine measurement must be taken within 1 minute after dissolving the tablet.
Page 37
Chlor całkowity jest mierzony bezpośrednio po wolnym chlorze bez opróżniania kuwety. Tabletka DPD N°3 jest dodawana do próbki wody, która zawiera już tabletkę DPD N°1 (rozpuszczoną). Chlor łączony jest obliczany jako chlor całkowity minus chlor wolny. Pomiaru wolnego chloru należy dokonać w ciągu 1 minuty od rozpuszczenia tabletki.
Page 39
Only if your water sample does contain Chlorine next to Chlorine Dioxide (both disinfectants used), the following procedure „A“ needs to be followed and Glycine* reagent needs to be used. Otherwise (only Chlorine Dioxide present), please follow procedure „B“. Pouze v případě, že vzorek vody obsahuje kromě oxidu chloričitého také...
Page 40
With Chlorine | S chlorem | Z chlorem | Klórral | Cu clor Glycine* Completely Dissolved TEST TEST Residue Tablet or Liquid? (p. 11) Completely Dissolved DPD N°1 TEST TEST Photometer Residue...
Page 41
Without Chlorine | Bez chlóru | Bez chloru | Klór nélkül | Fără clor Tablet or Liquid? (p. 11) Completely Dissolved TEST TEST DPD N°1 Residue Photometer 8a / 6 4.11 ppm TEST CLO2...
Cyanuric Acid Kyselina kyanurová Kwas cyjanurowy Cianursav Acid cianuric 0 – 160 ppm (mg/l) CYA-Test Photometer* *not part of Standard Equipment ZERO! (p. 19) Take 10 ml Water Sample ZERO...
Page 43
1 x CYA-Test Photometer* Completely Dissolved TEST TEST Residue TEST 42 ppm...
(LR) Hydrogen Peroxide Peroxid vodíku Nadtlenek wodoru Hidrogén-peroxid Peroxid de hidrogen 0.00 – 2.90 ppm (mg/l) Hydr. Peroxide LR Photometer* *not part of Standard Equipment ZERO! (p. 19) Take 10 ml Water Sample ZERO...
Page 45
1 x Hydr. Peroxide LR Photometer* Completely Dissolved TEST TEST Residue 1.4 ppm TEST H202...
(HR) Hydrogen Peroxide Peroxid vodíku Nadtlenek wodoru Hidrogén-peroxid Peroxid de hidrogen 0 – 200 ppm (mg/l) Hydr. Peroxide HR Photometer* | Acidifying *not part of Standard Equipment ZERO! (p. 19) Take 10 ml Water Sample ZERO...
Page 47
1 x Hydr. Peroxide HR Photometer* Completely Dissolved Residue TEST TEST 1 x Acidifying Completely Dissolved Residue TEST TEST 1.4 ppm TEST H202...
Page 48
Ozone Ozon Ózon Tablet Mode: Liquid Mode: 0.00 – 5.40 ppm (mg/l) 0.00 – 2.70 ppm (mg/l) DPD N°1 Photometer Tablet + DPD DPD N°3 Photometer Tablet DPD 3C Liquid* Glycine* Glycine* *not part of Standard Equipment ZERO! (p. 19) Take 10 ml Water Sample ZERO...
Page 49
Only if your water sample does contain Ozone next to Chlorine (both disinfectants used), the following procedure „B“ needs to be followed and Glycine* reagent needs to be used. Otherwise (only Ozone present), please follow procedure „A“. Pouze v případě, že váš vzorek vody obsahuje vedle chlóru i ozón (obě...
Page 50
Without Chlorine | Bez chlóru | Bez chloru | Klór nélkül | Fără clor Tablet or Liquid? (p. 11) Completely Dissolved DPD N°1 + TEST TEST DPD N°3 Residue Photometer 0.3 ppm TEST...
Page 51
With Chlorine | S chlorem | Z chlorem | Klórral | Cu clor Tablet or Liquid? (p. 11) Completely Dissolved DPD N°1 + 0.3 ppm 0.3 ppm DPD N°3 Residue Photometer 0.3 ppm STEP 2...
Page 52
STEP 2 Take 10 ml Water Sample Completely Glycine* Dissolved Residue STEP 2 STEP 2...
Page 54
Tablet Mode: Liquid Mode: 6.50 – 8.40 6.50 - 8.40 Phenol Red Photometer Phenol Red Liquid* *not part of Standard Equipment Take 10 ml Water Sample...
Page 55
ZERO! (p. 19) Phenol ZERO Red Photometer TEST Phenol Red* Completely Dissolved TEST TEST Residue...
Page 56
7.10 The Total Alkalinity value has to be minimum 50 mg/l to obtain a correct pH value. Hodnota celkové alkality musí být minimálně 50 mg/l, aby bylo dosaženo správné hodnoty pH. Całkowita wartość zasadowości musi wynosić minimum 50 mg/l, aby uzyskać prawidłową wartość pH. Az összes lúgossági értéknek legalább 50 mg/l-nek kell lennie a helyes pH-érték eléréséhez.
PHMB 5 – 60 ppm (mg/l) PHMB Photometer* *not part of Standard Equipment ZERO! (p. 19) Take 10 ml Water Sample ZERO...
Page 58
1 x PHMB Photometer* Completely Dissolved TEST TEST Residue TEST 42 ppm phmb...
Page 59
It is imperative that you clean the objects used for the measure-ment and come into contact with the sample water containing the reagent (cuvette, lid, stirring rod) thoroughly with a brush, water and then with distilled water, otherwise the measuring equipment may turn blue over time.
Total Hardness Celková tvrdost Twardość całkowita Teljes keménység Duritate totală 0 – 500 ppm (mg/l) CaCO POL20TH1* POL10TH2* *not part of Standard Equipment ZERO! (p. 19) Take 10 ml Water Sample ZERO...
Page 61
POL20TH1** POL10TH2** *Shake before using! 10 x TEST TEST 57 ppm TEST CACO3...
Page 62
Urea Močovina Mocznik Karbamid Uree 0.00 – 2.50 ppm (mg/l) Dechlor* | PL Urea | PL Urea Ammonia N°1* | Ammonia N° *not part of Standard Equipment ZERO! (p. 19) Take 10 ml Water Sample ZERO...
Page 63
Dechlor* TEST TEST Completely Dissolved TEST Residue TEST PL Urea *Shake before using! UREA 1...
Page 64
PL Urea *Shake before using! UREA 2 TEST Ammonia N°1...
Page 66
TEST 1.5 ppm Ch4n2o If the sample contains free chlorine, a „Dechlor“ tablet has to be added to the vial, before adding PL Urea 1 and PL Urea 2. Ammonia N°1 only dissolves entirely after Ammonia N°2 was added. Ammonia and chloramines will be detected together.
Page 67
Jeśli próbka zawiera wolny chlor, do fiolki należy dodać tabletkę „Dechlor” przed dodaniem PL Urea 1 i PL Urea 2. Amoniak N°1 rozpuszcza się całkowicie dopiero po dodaniu Amoniaku N°2. Amoniak i chloraminy zostaną wykryte razem. Wyświetlony wynik pokaże sumę obu. Temperatura próbki musi wynosić...
Page 68
OR-UR (Dilution) | OR-UR (ředění) | OR-UR (rozcieńczenie) | OR-UR (hígítás) | OR-UR (Diluție) OR = Overrange / UR = Underrange. Test result is outside the range of the method. OR results can be brought into measurement range by dilution. Use syringe to take only 5 ml (or 1 ml) sample water plus 5 ml (9 ml) distilled water.
Troubleshooting | Řešení problémů | Rozwiązywanie problemów | Hibaelhárítás | Rezolvarea problemelor 1) 01.01.1970: The date on the PoolLab 1.0 is set to 01.01.1970 ® when delivered, after each battery change and after each update. Please reconnect to the LabCOM app so that the smartphone date is adopted again.
Page 71
útmutatóban megadott tűréshatárokon belül. 6) A kijelzőn megjelenő páratartalom: Előfordulhat, ha a házban lévő maradék páratartalom a hideg víz miatt a merítés során kondenzálódik. 1) 01.01.1970: Data de pe PoolLab 1.0 este setată la 01.01.1970 ® la livrare, după fiecare schimbare a bateriei și după...
Page 72
Changing The Cuvette | Výměna kyvety | Wymiana kuwety | A küvetta cseréje | Schimbarea cuvei 90° 90°...
App & Software | Aplikacje & Oprogramowanie | Alkalmazás & Szoftver | Alkalmazás & Software Bluetooth ON Bluetooth OFF www.labcom.cloud Windows /MacOS ® ®...
Technical Data | Technická data | Dane techniczne | Műszaki adatok | Date tehnice www.poollab.org MSDS msds.water-id.com Cloud labcom.cloud LED: 530 nm / 570 nm / 620 nm 3 x AAA (1.5 V, Lr03) 5 min. 5 - 45°C IP 68 (1 h / 1.2 m) Developed in Germany Produced in PRC...
The manufacturer of this device, Water-i.d. GmbH, ® Daimlerstr. 20, D-76344 Eggenstein will dispose of your PoolLab 1.0 Photometer ® free of charge (not including costs of sending the device to us). Send your Pool- for disposal -freight prepaid - to the address shown above.
Page 82
UKCA Complaince Statement UK Conformity Assessed We, Water-i.d. GmbH Germany, hereby certify our responsibility, that the following product: PrimeLab 2.0 Photometer, is tested to and conforms with the essential test suites included in the following standards, which are in force within the UK: Standards Legislation Number EN 61000-3-2: 2014;...
Page 83
FCC Part 15 Compliance Statement IC Licence-Exempt RSS Compliance Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Page 84
Changes or modifications not expressly approved by Water-i.d. GmbH could void the user‘s authority to operate the equipment. FCC ID: 2ALRR-POOLLAB10 22610- POOLLAB10 Model: POOLLAB 1.0...
Certificate Of Compliance We hereby certify that the device PoolLab 1.0 ® With it‘s serial number as stated below, has passed intensive visual and technical checks as part of our QM documentation. We confirm the device got factory-calibrated. Water–i.d. GmbH (Germany) ®...
Need help?
Do you have a question about the PoolLAB 1.0 and is the answer not in the manual?
Questions and answers