E2S AlertAlight DL105H Instructions/Service Manual

E2S AlertAlight DL105H Instructions/Service Manual

Combined sounder led beacons
Hide thumbs Also See for AlertAlight DL105H:

Advertisement

Quick Links

INSTRUCTION & SERVICE MANUAL
DL105H AlertAlight Combined Sounder LED Beacons
• -40°C to +66C (-40°F to 151°F)
• Type 4 / 4X / 3R / 13, IP66
• 2.1Kg (4.62lb)
• CE, UKCA
• All units UL Listed.
Nominal
Unit Type Code
Voltage
#
12 V dc
DL105HDC024
24V dc
DL105HDC048
48V dc
115V ac
DL105HAC230
230V ac
*Nominal current at nominal voltage, Tone 12 / 1Hz Flash Pattern;
AC: 1.0 – 2.5mm
DC: 0.2 – 2.5mm
Attention
: Installation must be carried out by an electrician in compliance with the latest codes and regulations.
Attention
: L'installation doit être effectuée par un électricien conformément aux derniers codes et réglementations.
Achtung
: Die Installation muss von einem Elektriker gemäß den neuesten Vorschriften und Bestimmungen durchgeführt werden.
Attenzione
: L'installazione deve essere eseguita da un elettricista in conformità con i codici e le normative più recenti.
Atención
: La instalación debe ser realizada por un electricista de acuerdo con los últimos códigos y regulaciones.
Atenção:
A instalação deve ser realizada por um eletricista de acordo com os códigos e regulamentos mais recentes.
Внимание
: установка должна выполняться электриком в соответствии с последними нормами и правилами.
Attention
: Disconnect from power source before installation or service to prevent electric shock
Attention
: Débranchez-le de la source d'alimentation avant l'installation ou l'entretien pour éviter tout choc électrique.
Achtung
: Vor Installation oder Wartung von der Stromquelle trennen, um einen Stromschlag zu vermeiden.
Attenzione
: scollegare dall'alimentazione prima dell'installazione o dell'assistenza per evitare scosse elettriche.
Atención
: desconéctelo de la fuente de alimentación antes de la instalación o el servicio para evitar descargas eléctricas.
Atenção:
Desconecte da fonte de alimentação antes da instalação ou serviço para evitar choque elétrico
Внимание
: отключите от источника питания перед установкой или обслуживанием, чтобы предотвратить поражение электрическим током.
E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH
Voltage
Nominal
Range
Sounder
10-14Vdc
17mA
16-33Vdc
33.5mA
(Regulated)
48-60Vdc
113mA
25mA
48 - 260Vac
50/60Hz
17mA
2
/ AWG18 – AWG12
2
/ AWG24 – AWG12
Nominal
Nominal SPL
Beacon
79.5mA
87mA
105.3dB(A)
60mA
Tone 44 @ 1m
34mA
19mA
#
Factory Default setting 24Vdc, beacon customer settable to 12Vdc
Sheet 1 of 5
e2s.com
Max SPL
Average SPL
110.9dB(A)
105.2dB(A) All
Tone 4 @ 1m
tones @1m
0.4Nm
D172-00-301-IS Issue 5 31/07/2024

Advertisement

loading
Need help?

Need help?

Do you have a question about the AlertAlight DL105H and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for E2S AlertAlight DL105H

  • Page 1 Desconecte da fonte de alimentação antes da instalação ou serviço para evitar choque elétrico Внимание : отключите от источника питания перед установкой или обслуживанием, чтобы предотвратить поражение электрическим током. E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH Sheet 1 of 5 e2s.com...
  • Page 2 DC (+ve switching) see Default = S2 - Tone 1 Default = S1 - Tone 44 (ON = 1, OFF = 0) E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH Sheet 2 of 5 e2s.com D172-00-301-IS Issue 5 31/07/2024...
  • Page 3 Pre-determined by Stage 1 selection - see Tone 2c/6c Apply +ve to terminal ‘+’ & -ve to terminal ‘-‘ table D218-95-001-IS E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH Sheet 3 of 5 e2s.com D172-00-301-IS Issue 5 31/07/2024...
  • Page 4 Open Closed (Customer Set) Jumper Link 5 Open E - + D105HDC024 Beacon PCBA (12VDC Mode – Customer to Set) E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH Sheet 4 of 5 e2s.com D172-00-301-IS Issue 5 31/07/2024...
  • Page 5 NFPA 70 ou CSA 22.1 Code canadien de l'électricité, première partie, norme de sécurité relative aux installations électriques, Section 32 E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH Sheet 5 of 5 e2s.com...
  • Page 14 Page left Intentionally blank...
  • Page 15 Page left Intentionally blank...
  • Page 16 Page left Intentionally blank...

This manual is also suitable for:

Dl105hdc024Dl105hdc048Dl105hac2302-31-370