Settings & Operation Guide
Madimack InverPro Series
1.) Power Consumption
2.) Running Capacity / Flow Rate
3.) Wi-Fi Indicator
4.) Unit of Flow
5.) Timer Period
6.) Timer 1/2/3/4
Before Operation
Fill the basket with water before starting up the pump. Check to ensure the power
consumption is within range.
When the screen is locked, the Lock button will appear. Press and hold the Lock button for
three seconds to access the settings menu. The pump will automatically lock after 1 minute of
user inactivity.
Press the lock button to wake the screen and view current operating parameters.
Self-Priming
When switched on, the pump will start a self-priming procedure. A countdown will appear
starting at 1500s and stop when the priming is complete. The pump will recheck for 120s to
ensure the priming is completed.
To exit self-priming mode, press and hold the Lock button for three seconds. This will return
the pump to its previous state before the last shutdown (the pump will go to Manual Mode for
new installations)
To manually activate self-priming mode, hold both the Lock and Mode buttons for three
seconds.
Lock
Hold down this button to unlock the screen.
Mode
Switch between Auto-Inverter and Manual
mode.
Auto Inverter Mode
The running capacity (%) will fluctuate
according to the preset flow rate.
Manual Mode
The running capacity is preset between 30% -
120%.
UP
Change the selected value up.
DOWN
Change the selected value down.
Timer Setting
Change timer settings.
Power
Turns the pump on / off.
1333 Rymal Road East
Hamilton, ON L8W 3N1
(905)-388-5391
www.thepoolshoppe.ca
info@thpoolshoppe.ca

Advertisement

loading
Need help?

Need help?

Do you have a question about the InverPro Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Madimack InverPro Series

  • Page 1 Settings & Operation Guide Madimack InverPro Series Lock Hold down this button to unlock the screen. Mode Switch between Auto-Inverter and Manual mode. Auto Inverter Mode The running capacity (%) will fluctuate according to the preset flow rate. Manual Mode The running capacity is preset between 30% - 120%.
  • Page 2 Modes Press the Mode button to toggle between manual mode and auto-inverter mode. Manual Mode While in manual mode, the running capacity (shown in %) will appear on the screen. Press the Up or Down buttons to adjust the running capacity between 30% and 120%. The user can set the running capacity between 105% and 120% to maintain an adequate flow rate when pipeline pressure is high.