E: team.dach@megger.com Megger All rights reserved. No part of this handbook may be copied by photographic or other means unless Megger have before-hand declared their consent in writing. The content of this handbook is subject to change without notice. Megger cannot be made liable for technical or printing errors or shortcomings of this handbook. Megger also disclaims all responsibility for damage resulting directly or indirectly from the delivery, supply, or use of this matter.
Each component and product replaced in accordance with this warranty becomes the property of Megger. All warranty claims versus Megger are hereby limited to a period of 12 months from the date of delivery. Each component supplied by Megger within the context of warranty will also be covered by this warranty for the remaining period of time but for 90 days at least.
It is important to observe the generally applicable electrical regulations of the country in Working with products from Megger which the device will be installed and operated, as well as the current national accident prevention regulations and internal company directives (work, operating and safety regulations).
Page 8
The thresholds listed in the technical data may not be exceeded under any circumstances. Repair and maintenance work has to be carried out by Megger or authorised service Repair and partners using original spare parts only. Megger recommends having the system tested maintenance and maintained at a Megger service centre once a year.
Technical description Technical description System description The audio frequency generator FLG 12 is a robust, portable measuring device that can Description be used in combination with a suitable receiver for tasks that include the following ones: Searching for and routing metallic conductors •...
Page 10
Megger Sales: Accessory Description Item number Isolating filter For connecting the FLG 12 to live low-voltage 1014888 TF 10 cables up to 420 V. The generator must only be operated with a maximum output power of 10 W when...
Technical description Technical data The generator is defined by the following technical parameters: Parameter Value Output power 0 – 12 W Output frequencies 491 Hz, 512 Hz, 640 Hz, 982 Hz, 1090 Hz, 8440 Hz, 9820 Hz, 32768 Hz Impedance matching Automatic from 0.5 –...
Technical description Connections and controls The following illustration shows the connections and controls on the generator: Element Description Display Signal output sockets Mains power supply connection socket LED to indicate the charge status 6.3 A fine wire fuse, slow Knob Membrane key with following functions: Indicator unit on/off (when pressed and held) •...
Battery/mains operation Battery/mains operation The FLG 12 features a high-capacity Li-ion rechargeable battery that can be operated at maximum transmission power for around 2.5 hours when fully charged. At a lower transmission power, an operating period of more than 10 hours is possible.
Setup/connection Setup/connection WARNING Risk of injury from electric shock The voltage at the signal output sockets can exhibit values of >25 V, making them dangerous to touch. The device may only be switched on after connection to the measurement object! Operation on voltage-free lines WARNING Risk of fatal injury from electric shock...
Page 15
Setup/connection A direct connection to the measurement object must be made using the connection cables provided. Depending on the purpose of the measurement and the method used, the type of connection may vary. When locating/routing cables, a signal return current must be ensured through contact with the ground or, if necessary, through connection to an alternative conductor.
Page 16
Setup/connection Particularly in cases where the lines are without ground isolation, the other end of the cable should be grounded or a loop test should be carried out where possible. Specific connection methods for locating sleeves and faults in twisted multi- core cables are provided in the operating instructions for the audio frequency receiver.
Selective inductive coupling by means of transmitter tongs With the aid of suitable feeding pliers from the range of Megger products, the audio frequency signal can also be inductively coupled to a specific cable or pipe as well. To do so, the pliers are placed around the conductor as shown below.
Putting the generator into operation Putting the generator into operation General Switching on the Once the generator has been connected, it can be switched on by pressing the button generator briefly. Directly after switching on the generator, load detection is performed and internal load matching is automatically performed on the basis of the load impedance determined.
Page 19
Putting the generator into operation The main screen provides all relevant information on the device settings and signal Elements of the main properties when a signal is being transmitted on a conductor: screen Currently active signal frequency Battery status Signal properties (continual, pulsed, Currently active SignalSelect)
Putting the generator into operation Adjusting the settings It is possible to switch from the main screen to the menu screen at any time and enter Menu structure any setting with a maximum of three operating steps: Main screen Menu screen By principle, the individual menu screens have the following layout: Elements of the menu screens...
Putting the generator into operation 5.2.1 Adjusting the basic settings When the generator is switched on, you can access the basic settings by pressing the knob to switch to the menu screen, and then select the menu item . The following menu then appears in the display: You can enter the following basic settings in this menu: Menu...
Putting the generator into operation 5.2.2 Adjusting the measurement settings Pressing the knob allows you to exit the measurement screen and directly access the menu screen at any time, which contains the most important measurement settings: The following measurement settings can be entered in this screen: Menu Description item...
Switching off the generator Switching off the generator After the line has been successfully located / traced, the generator can be turned off by button for 3 seconds. pressing the...
Storage and care Storage and care You should store the device in a dry and sheltered environment which provides adequate Storage protection against mechanical damage and dirt. The storage temperatures shown in the technical data must be adhered to. Apply topping charge every three months. Do not clean the display with aggressive products such as solvents or spirits.
Page 25
Tento symbol indikuje, že výrobek nesoucí takovéto označení nelze likvidovat společně s běžným domovním odpadem. Jelikož se jedná o produkt obchodovaný mezi podnikatelskými subjekty (B2B), nelze jej likvidovat ani ve veřejných sběrných dvorech. Pokud se potřebujete tohoto výrobku zbavit, obraťte se na organizaci specializující se na likvidaci starých elektrických spotřebičů...