Helo Magma 1101-1811 Installation And User Manual
Helo Magma 1101-1811 Installation And User Manual

Helo Magma 1101-1811 Installation And User Manual

Hide thumbs Also See for Magma 1101-1811:

Advertisement

Quick Links

Installation and User Manual
ELECTRIC SAUNA HEAT
1101 – 1811 Magma
1101 – 2101 Magma
1101 – 2601 Magma
1101 – 181
SKLA
1101 – 210
SKLA
1101 – 260
SKLA
CONTACTOR BOX
2005 – 50
WE 50
2005 – 51
WE 51
2005 – 52
WE 52
CONTROL PANELS
1601 – 41
Pure
1601 – 42
Elite
Pure
Magma ja SKLA
MAGMA
Elite
SKLA
314 SKLA 66-3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Magma 1101-1811 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Helo Magma 1101-1811

  • Page 1 Installation and User Manual Magma ja SKLA ELECTRIC SAUNA HEAT 1101 – 1811 Magma 1101 – 2101 Magma MAGMA 1101 – 2601 Magma 1101 – 181 SKLA 1101 – 210 SKLA 1101 – 260 SKLA CONTACTOR BOX 2005 – 50 WE 50 2005 –...
  • Page 2: Table Of Contents

    MAGMA SKLA Installation and User Manual Contents Page 1. VARNINGAR 1.1. Check before taking a sauna bath 1.2. Sauna room 1.3. Information for use 1.4. Operation of the sauna heater controls Preparing for sauna heater installation 2.1. Installation 2.2. Ceiling installation of the sensor 2.3.
  • Page 3: Varningar

    MAGMA SKLA Installation and User Manual 1. VARNINGAR 1.1. Check before taking a sauna bath The sauna room is suitable for taking a sauna bath. The door and the window are closed. The sauna heater is topped with stones that comply with the manufacturer's recommendations, the heating elements are covered with stones, and the stones are piled sparsely.
  • Page 4: Preparing For Sauna Heater Installation

    MAGMA SKLA Installation and User Manual 2. Preparing for sauna heater installation Check the following before installing the sauna heater. The ratio of the heater's input (kW) and the sauna room's volume (m ). Volume recommendations are presented in Table 5 on page 11. The minimum and maximum volumes must not be exceeded. The height of the sauna room must be at least 2100 mm or 2200 mm depending on the heater power.
  • Page 5: Using The Contactor Cases

    MAGMA SKLA Installation and User Manual 2.4. Using the contactor cases The contactor case 2005 – 50 (WE – 50), 2005 – 52 (WE - 52) as well as an additional contactor case 2005 – 51 (WE – 51) supplied with the second heater can be used with the following sauna heaters: - SKLE, LAAVA.…1105 - ….
  • Page 6: Connection Of The Sauna Heater To The Mains

    MAGMA SKLA Installation and User Manual 2.6. Connection of the sauna heater to the mains The sauna heater must be connected to the mains by a qualified electrician and in compliance with current regulations. sauna heater is connected with a semi-permanent connection. Use H07RN-F (60245 IEC 66) cables or a corresponding type. Other output cables (signal lamp, electric heating toggle) must also adhere to these recommendations.
  • Page 7: Door Switch

    The switch part is installed on the door frame and the magnet is installed on the door. The distance between the switch and the magnet is 18 mm. When the door switch is installed on the top part of the door, TylöHelo recommends using the TylöHelo model with product number 0043233, SSTL 8260371.
  • Page 8: Principle Diagram

    MAGMA SKLA Installation and User Manual 2.12. Principle diagram Terminal block Limiter Contactor box WE - 50 Sensor cable 1 Blue OLEA 103 2 White 3 Red 4 Yellow Control panel Contactor box Pure WE - 50 1 Yellow 2 Green OLEA 103 3 Red 4 Black...
  • Page 9: Connection Principle

    MAGMA SKLA Installation and User Manual 2.13. Connection principle 400V – 415V 3N~ 2- power group 230V 3~ 2- power group OLET 31 OLET 31 Heater Herater Croup 1 Group 2 Group 1 Group 2 N L1 L2 L3 N L1 L2 L3 N U V W N U V W OLEA 103...
  • Page 10: Cables And Fuses For Heaters 1101 - Xx (Skla / Magma) And Sensor Olet

    MAGMA SKLA Installation and User Manual 2.14. Cables and fuses for heaters 1101 – XX (SKLA / Magma) and sensor OLET 31 installation location Sauna heaters Sauna heaters connection cable connection cable Fuse Fuse Power H07RN-F / H07RN-F / Model 60245 IEC 66 60245 IEC 66 400V –...
  • Page 11: Internal Connection For Sauna Heaters Magma / Skla

    MAGMA SKLA Installation and User Manual Power Sauna volume Minimum distances Adequate amount of stones To the Minimi- To the To the To the Min. Max. side height Fornt ceiling back wall Approx. kg 18,0 2100 1400 (9+9) 21,0 2100 1400 (9+12) 26,0...
  • Page 12: Recommended Sauna Room Ventilation

    MAGMA SKLA Installation and User Manual 2.17. Recommended sauna room ventilation 1000 mm 500 mm Figure 10 Recommended sauna room ventilation 1. Sauna room 3. Electric sauna heater 5. Exhaust flue or channel 2. Washroom 4. Exhaust valve 6. Door to the sauna room 7.
  • Page 13: Magma / Skla Spare Part List

    MAGMA SKLA Installation and User Manual 3. Magma / SKLA Spare part list Part Part number Part name 18,0 kW 21,0 kW 26,0 kW SP7812550 Mains connector SP4316215 Heating element SEPC 12 230V 1500W SP4316216 Heating element SEPC 11 230V 2000W SP4316217 Heating element SEPC 12...