Download Print this page
Johnson Controls tyco HSM3105 Installation Manual
Johnson Controls tyco HSM3105 Installation Manual

Johnson Controls tyco HSM3105 Installation Manual

Expansion module

Advertisement

Quick Links

HSM3105 Expansion Module Installation
Guide
HSM3105
*29011148R001*
29011148R001
© 2022 Johnson Controls. All rights reserved.

Advertisement

loading
Need help?

Need help?

Do you have a question about the tyco HSM3105 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Johnson Controls tyco HSM3105

  • Page 1 HSM3105 Expansion Module Installation Guide HSM3105 *29011148R001* 29011148R001 © 2022 Johnson Controls. All rights reserved.
  • Page 2 HSM3105 Expansion Module Installation Guide © 2022 Johnson Controls. All rights reserved.
  • Page 3: Table Of Contents

    Status LED............................... 14 Firmware update indications......................14 MX diagnostics..............................15 Limited Warranty............................15 Software Product License..........................15 FCC and ISED Canada Information......................18 Modification statement........................18 FCC class B digital device notice......................18 HSM3105 Expansion Module Installation Guide © 2022 Johnson Controls. All rights reserved.
  • Page 4 HSM3105 Expansion Module Installation Guide © 2022 Johnson Controls. All rights reserved.
  • Page 5: Mx Expander

    MX loop maximum loading table below. • Board current draw: 100 mA (with no devices on the MX loop) + MX Loop current draw (depending on the connected loop devices) HSM3105 Expansion Module Installation Guide © 2022 Johnson Controls. All rights reserved.
  • Page 6: Familiarization With The Hsm3105 Module

    CORBUS - The panel uses the 4-wire Corbus to communicate with the module. Connect the RED, BLK, YEL and GRN terminals to the Corbus terminals on the IQ Pro main control. HSM3105 Expansion Module Installation Guide © 2022 Johnson Controls. All rights reserved.
  • Page 7: Compatibility

    (See Enclosures) from the control panel, as shown in Figure 1 and 2 respectively. The Corbus wire runs between the control panel and the HSM3105 and shall not exceed 3ft using 22AWG wire. HSM3105 Expansion Module Installation Guide © 2022 Johnson Controls. All rights reserved.
  • Page 8 Figure 2: Low Power Mode – External Mount MX loop IQ Pro/IQ Pro P enclosure HS M3105 enclosure HS M3105 Power AC mains IQ Pro/IQ Pro P adapter COR BUS HSM3105 Expansion Module Installation Guide © 2022 Johnson Controls. All rights reserved.
  • Page 9: High Power Mode - External Mount

    HS M2204/HS M2300 Power S upply RED BLK YEL GRN 18VDC BELL CORBUS AUX 1 AUX 2 RED BLK YEL GRN AC AC AUX+ RED BLK YEL GRN TAM 01 HSM3105 Expansion Module Installation Guide © 2022 Johnson Controls. All rights reserved.
  • Page 10: Mx Addressable Loop Wiring Configuration

    Select Installation > Devices > Security Sensors > MX Module. Click Configuration. Click Bus Configuration and select the required Spur or Loop configuration based on the site requirement. HSM3105 Expansion Module Installation Guide © 2022 Johnson Controls. All rights reserved.
  • Page 11: Current Loading On The Mx Loop

    The output would be the current loading on the MX loop and the percentage of max load used. The installer can pick and choose which MX devices to be added/removed on the MX loop to avoid overloading the system. HSM3105 Expansion Module Installation Guide © 2022 Johnson Controls. All rights reserved.
  • Page 12: Mx Bus Wire Length

    6562 FT 2000 6435 FT 1961 4926 FT 1502 3086 FT 940 6562 FT 2000 6562 FT 2000 6562 FT 2000 5975 FT 1821 4574 FT 1394 2866 FT 873 HSM3105 Expansion Module Installation Guide © 2022 Johnson Controls. All rights reserved.
  • Page 13: Enclosures

    414 mm x 103 mm, weight: 11.5 lb or 4.3 Kg • Model HSC3001C (hinged door) made of 22Ga steel, dimension 260mm x 237 mm x 69 mm, weight 1.2kg HSM3105 Expansion Module Installation Guide © 2022 Johnson Controls. All rights reserved.
  • Page 14: Automatically Enrolling On The Alarm Panel

    If the firmware upgrade fails, the status LED flash: 200 ms on / 200 ms off. This cadence shall clear when the firmware upgrade process is reattempted HSM3105 Expansion Module Installation Guide © 2022 Johnson Controls. All rights reserved.
  • Page 15: Mx Diagnostics

    (“Device”). In other words, if You have several workstations, You will have to acquire a license for each workstation where the SOFTWARE will be used. HSM3105 Expansion Module Installation Guide © 2022 Johnson Controls. All rights reserved.
  • Page 16 (e) EXCLUSIVE REMEDY AND LIMITATION OF WARRANTY - UNDER NO CIRCUMSTANCES SHALL DSC BE LIABLE FOR ANY SPECIAL, INCIDENTAL, CONSEQUENTIAL OR INDIRECT DAMAGES BASED UPON BREACH OF WAR- HSM3105 Expansion Module Installation Guide © 2022 Johnson Controls. All rights reserved.
  • Page 17 However, despite frequent testing, and due to, but not limited to, criminal tampering or electrical disrup- tion, it is possible for this SOFTWARE PRODUCT to fail to perform as expected. HSM3105 Expansion Module Installation Guide © 2022 Johnson Controls. All rights reserved.
  • Page 18: Fcc And Ised Canada Information

    • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. ISED Canada CAN ICES-3(B)/NMB-3(B) © 2022 Johnson Controls. All rights reserved.