TemporalScanner ™ TAT-5000S-MUSB Accurate Temperature with a Gentle Forehead Scan TemporalScanner ™ Operation Manual Changing the Way the World Takes Temperature...
Page 2
The patented arterial heat balance technology (AHB™) automatically The link to www.exergen.com/s measures the temperature of the appears on the front label of the skin surface over the artery and the instrument as a scannable “QR”...
READ ALL INSTRUCTIONS BEFORE USING Additionally, the TAT-5000S series thermometers are not for use aboard aircraft Intended Use: The Exergen TemporalScanner or near High Frequency Surgical Equipment or is a handheld infrared thermometer used Radio Frequency shielded rooms, such as MRI by medical professionals for the intermittent (Magnetic Resonance Imaging) areas.
Page 4
(other than TAT-5000S service, repair, or adjustments, return your compatible patient monitors) should be avoided thermometer to Exergen. Warning : no because it could result in improper operation. modification of this equipment is allowed. If such use is necessary, this equipment and •...
• Lateral thoracic artery: slowly scan side-to- side in the area ~midway between the axilla and the nipple. Product Map of the Exergen This method of temperature assessment has TemporalScanner TAT-5000S-MUSB been shown to improve results and reduce costs...
Page 6
Measurement site must be exposed. At mid-line, the temporal artery is about 2 mm below the surface, but can go deeply below the surface on the side of the face. page 6 Exergen TAT-5000S-MUSB...
Page 7
2 dissipating, resulting in mm below the surface, but can falsely high readings. go deeply below the surface on the side of the face. Minimum measuring time: 2 seconds. Minimum time between successive measurements: 30 seconds Exergen TAT-5000S-MUSB page 7...
30 seconds wait about 30 seconds for the skin to recover for the previously from the cold probe. covered area to equilibrate to the environment. page 8 Exergen TAT-5000S-MUSB...
5 seconds and reading the temperature display for 3 film left by the alcohol. Do not use bleach or seconds before turning thermometer off. other cleaning solutions on the sensor lens. DO NOT SUBMERSE THE THERMOMETER IN ANY CLEANING SOLUTION. Exergen TAT-5000S-MUSB page 9...
Page 10
LO A < 16 °C (61° F) Low Battery bAtt No or Very Low Battery blank display Processing Error Restart. Return to Exergen for repair if error message persists. Scanning - - - - (Normal Operation) Fahrenheit or Celsius Conversion The TemporalScanner can be used in either °F or...
Page 11
Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3V/m. c. Portable and mobile RF communications equipment can affect performance. d. Device does not require any maintenance to maintain basic safety and essential performance over the expected service life. Exergen TAT-5000S-MUSB page 11...
Page 12
At 80 MHz and 800 MHz the separation distance for the higher frequency range applies. Note 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. page 12 Exergen TAT-5000S-MUSB...
Page 13
Repair If repair is required, please go to our website at www.exergen.com/rma to request a Return Materials Authorization (RMA) number. You will receive an email response with an RMA number and instructions on where to return your unit. Alternatively, you may contact Exergen customer service at (617) 923-9900 or service@exergen.com or...