Exergen TemporalScanner TAT-5000S-US Series Operation Manual

Exergen TemporalScanner TAT-5000S-US Series Operation Manual

Accurate temperature with a gentle forehead scan

Advertisement

TemporalScanner
TemporalScanner
Operation Manual
Changing the Way the World Takes Temperature
Exergen TAT-5000S-US
TAT-5000S-US Series
Accurate Temperature with a
Gentle Forehead Scan
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TemporalScanner TAT-5000S-US Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Exergen TemporalScanner TAT-5000S-US Series

  • Page 1 TAT-5000S-US Series TemporalScanner ™ Accurate Temperature with a Gentle Forehead Scan TemporalScanner ™ Operation Manual Changing the Way the World Takes Temperature Exergen TAT-5000S-US...
  • Page 2 The patented arterial heat balance technology (AHB™) automatically The link to www.exergen.com/s measures the temperature of the appears on the front label of the skin surface over the artery and the instrument as a scannable “QR”...
  • Page 3: Important Safety Instructions

    READ ALL INSTRUCTIONS BEFORE USING Additionally, the TAT-5000S series thermometers are not for use aboard aircraft Intended Use: The Exergen TemporalScanner or near High Frequency Surgical Equipment or is a handheld infrared thermometer used Radio Frequency shielded rooms, such as MRI by medical professionals for the intermittent (Magnetic Resonance Imaging) areas.
  • Page 4 Use of this equipment adjacent to or stacked service, repair, or adjustments, return your with other equipment (other than TAT-5000S thermometer to Exergen. Warning : no compatible patient monitors) should be avoided modification of this equipment is allowed. because it could result in improper operation.
  • Page 5: Introduction To Temporal Artery Thermometry

    • To Retain or Lock Reading: The reading will remain on the display for 30 seconds after button is released. If measuring room temperature, the temperature will remain on the display for only 5 seconds. Exergen TAT-5000S-US...
  • Page 6 Measurement site must be exposed. At mid-line, the temporal artery is about 2 mm below the surface, but can go deeply below the surface on the side of the face. Exergen TAT-5000S-US...
  • Page 7 2 dissipating, resulting in mm below the surface, but can falsely high readings. go deeply below the surface on the side of the face. Minimum measuring time: 2 seconds. Minimum time between successive measurements: 30 seconds Exergen TAT-5000S-US...
  • Page 8: Frequently Asked Questions

    30 seconds wait about 30 seconds for the skin to recover for the previously covered area to from the cold probe. equilibrate to the environment. Exergen TAT-5000S-US...
  • Page 9: Care And Maintenance

    Water can be used to remove any residual film left by the alcohol. Do not use bleach or other cleaning solutions on the sensor lens. DO NOT SUBMERSE THE THERMOMETER IN ANY CLEANING SOLUTION. Exergen TAT-5000S-US...
  • Page 10 LO A < 16 °C (61° F) Low Battery bAtt No or Very Low Battery blank display Processing Error Restart. Return to Exergen for repair if error message persists. Scanning - - - - (Normal Operation) Fahrenheit or Celsius Conversion The TemporalScanner can be used in either °F or...
  • Page 11 Return Materials Authorization (RMA) number. You will receive an email response with an RMA number and instructions on where to return your unit. Alternatively, you may contact Exergen customer service at (617) 923-9900 or service@exergen.com or contact your local distributor.
  • Page 12 3. Slide additional film under fingers while using. Resposable covers can be discarded in normal trash. The operator is responsible for checking the compatibility of the thermometer, probe cover, and monitoring equipment. Incompatible components can result in degraded performance. Exergen p/n Description 134203...
  • Page 13: Verification Testing

    In the unlikely event recalibration might be required, the thermometer must be returned to Exergen for the procedure. However, calibration can be verified in the lab or clinical units quite easily using Exergen calibration kits. See:https://www.exergen.com/professional-medical-products/products/calibration-verification-kit and: https://www.exergen.com/professional-medical-products/products/professional-product-manuals...
  • Page 14 Correction method is proprietary. Laboratory testing protocol for laboratory accuracy available upon request. EXERGEN CORPORATION 400 PLEASANT STREET WATERTOWN, MA 02472 PH (617) 923-9900 www.exergen.com TemporalScanner ™ © 2022 Exergen Corporation Document p/n 818694r1 Changing the Way the World Takes Temperature TemporalScanner ™ Exergen TAT-5000S-US...

This manual is also suitable for:

Temporalscanner tat-5000s-

Table of Contents