Download Print this page

Lambda LJS-12 Series Instruction Manual page 6

Regulated power supplies

Advertisement

REMOTE
ON-OFF CONTROL
— The DC output of all LJS-12 power supplies can be turned on and off
remotelv bv means of digital command.
pope bevel
OOO
RT
сила
ARR
0 to 45 volts (logic "0" for ON, logic "1" for OFF)
Loading
сле
з
elses Petes
NE
1.6 ma sinking required (TTL compatible)
STORAGE
TIME
— 16 ms min. at full rated current, maximum rated output voltage, and 105 VAC input.
OVERSHOOT
No overshoot under conditions of power turn-on, turn-off, or power failure.
INPUT
AO Input 31555... 4... МЕЕ
У 105-132 VAC at 47-440 Hz. Input power: 195 Watts*.
For operation at frequencies above 440 Hz, consult
factory.
*With output loaded to full current rating.
DC Input...
u.a: des
a
2 ERORE 145 VDC +10%. Input power 195 Wattst.
TWith output loaded to full current rating.
INPUT FUSE — Fuse F1 protects the input wiring to the power supply. Overload of power supply does not
cause fuse failure.
OVERLOAD
PROTECTION
'Thermals.
м
у л ЕСУШ
se
КО! Thermostat
resets
automaticallv
when
оуег-
temperature condition is eliminated.
iġib
л жылы
ы
A
HUS
EN
Automatic
electronic
current
limiting circuit,
limits
output
current
to a preset
safe
value.
Automatic
current limiting protects the load and power supplv
when external overloads and direct shorts occur.
OVERVOLTAGE
PROTECTION
— All LJS-12 models include fixed built-in overvoltage protection circuits
which prevent damage to the load caused by. excessive power supply output voltage. See table below for
overvoltage protector firing ranges.
TRIP-POINT RANGE
MODEL
(VOLTS)
2
IM-LJS-12
OVERVOLTAGE
PROTECTOR

Advertisement

loading
Need help?

Need help?

Do you have a question about the LJS-12 Series and is the answer not in the manual?

Questions and answers