SPECIFICATION SANDFEATURES
TABLEI
VOLTAGE AND CURRENT RANGES
VOLTAGE
RANGE
MAXIMUM
CURRENT
(AMPS)
AT AMBIENT TEMPERATURE
Current range must be chosen to suit the appropriate
for entire voltage range.
REGULATED
VOLTAGE
OUTPUT
Regulation
Ripple and Noise
Temperature
Coefficient
Remote Programming
External Resistor
Programming Voltage
Remote Sensing
IM-LJS-12
maximum ambient temperature. Current ratings apply
0.490 line or load with input variations from 105-132 or
132-105 volts AC and load variations from no load to
full load.
10mV
RMS,
50mV
peak-to-peak
for
LJS-12-5-OV,
-6-OV models;
15mV
RMS,
100mV
peak-to-peak
for
LJS-12-12-OV,
-15-OV,
-20-OV,
-24-OV,
and -28-OV
with either positive or negative terminal grounded.
Change in output voltage 0.03% /°С max.
Nominal
1000 ohms/volt output.
One-to-one voltage change.
Provision is made for remote sensing to eliminate effect
of power output lead resistance on DC regulation.