Anritsu MP1800A Operation Manual
Anritsu MP1800A Operation Manual

Anritsu MP1800A Operation Manual

Signal quality analyzer
Hide thumbs Also See for MP1800A:

Advertisement

Quick Links

A l l t e s t I n s t r u me n t s , I n c .
5 0 0 C e n t r a l A v e .
F a r mi n g d a l e , N J 0 7 7 2 7
P : ( 7 3 2 ) 9 1 9 - 3 3 3 9
F : ( 7 3 2 ) 9 1 9 - 3 3 3 2
a l l t e s t . n e t
s s a l e s @ a l l t e s t . n e t
T h e t e s t & me a s u r e me n t
e q u i p me n t y o u n e e d a t
t h e p r i c e y o u w a n t .
A l l t e s t c a r r i e s t h e w o r l d ' s l a r g e s t s e l e c t i o n o f
u s e d / r e f u r b i s h e d b e n c h t o p t e s t & me a s u r e me n t
e q u i p me n t a t 5 0 % t h e p r i c e o f n e w .
O O u r e q u i p me n t i s g u a r a n t e e d w o r k i n g , w a r r a n t i e d , a n d
a v a i l a b l e w i t h c e r t i f i e d c a l i b r a t i o n f r o m o u r i n - h o u s e s t a f f
o f t e c h n i c i a n s a n d e n g i n e e r s .
• 1 0 + f u l l t i me t e c h n i c i a n s w i t h o v e r 1 5 0 y e a r s o f
s p e c i a l i z a t i o n
• 9 0 d a y w a r r a n t y & 5 d a y r i g h t o f r e t u r n o n a l l
e q u i p me n t
• • 1 - 3 y e a r w a r r a n t i e s f o r n e w a n d
p r e mi u m- r e f u r b i s h e d e q u i p me n t
• E v e r y u n i t t e s t e d t o O E M s p e c i f i c a t i o n s
• S a t i s f a c t i o n g u a r a n t e e d
Y o u h a v e p l a n s , w e w i l l h e l p y o u a c h i e v e t h e m.
A n y p r o j e c t . A n y b u d g e t .
t
G e t a q u o t e t o d a y !
C C a l l ( 7 3 2 ) 9 1 9 - 3 3 3 9 o r e ma i l s a l e s @a l l t e s t . n e t .

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MP1800A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Anritsu MP1800A

  • Page 1 T h e t e s t & me a s u r e me n t e q u i p me n t y o u n e e d a t t h e p r i c e y o u w a n t . A l l t e s t I n s t r u me n t s , I n c .
  • Page 2 MP1800A Signal Quality Analyzer Operation Manual Ninth Edition  For safety and warning information, please read this manual before attempting to use the equipment.  Additional safety and warning information is provided within MP1800A Signal Quality Analyzer Installation Guide. Please also refer to this document before using the equipment.
  • Page 3: Safety Symbols

    Ensure that you clearly understand the meanings of the symbols BEFORE using the equipment. Some or all of the following symbols may be used on all Anritsu equipment. In addition, there may be other labels attached to products that are not shown in the diagrams in this manual.
  • Page 4 Cautions against computer virus infection  Copying files and data Only files that have been provided directly from Anritsu or generated using Anritsu equipment should be copied to the instrument. All other required files should be transferred by means of USB or CompactFlash media after undergoing a thorough virus check.
  • Page 6: About This Manual

    About This Manual A testing system combining an MP1800A Signal Quality Analyzer or MT1810A 4-Slot Chassis mainframe, module(s), and control software is called a Signal Quality Analyzer Series. The operation manuals of the Signal Quality Analyzer Series consist of separate documents for the installation guide, the mainframe, remote control operation, module(s), and control software, as shown below.
  • Page 7: Table Of Contents

    Table of Contents About This Manual..........I Chapter 1 Overview ........... 1-1 Product Overview ............1-2 Product Composition ............ 1-3 Specifications ..............1-5 Chapter 2 Preparations ........2-1 Measures Against EOS and ESD ......... 2-2 Chapter 3 Panels and Connections ....3-1 Front Panel ..............
  • Page 8: Chapter 1 Overview

    Chapter 1 Overview This chapter provides an overview and the specifications of the MP1800A Signal Quality Analyzer (hereinafter, referred to as “MP1800A”). Product Overview ............1-2 Product Configuration ........... 1-3 1.2.1 Standard Configuration ........1-3 1.2.2 Options ............. 1-4 1.2.3 Optional Accessories ........1-4...
  • Page 9: Product Overview

    MU181020A 12.5 Gbit/s PPG and MU181040A 12.5 Gbit/s ED, among the installable modules, the number of controllable modules can be increased to 2, 4 or 6 by selecting an optimal option to the MP1800A. The MP1800A is equipped with LCDs, keys and a rotary encoder for easy operation.
  • Page 10: Product Configuration

    Product Configuration 1.2 Product Configuration 1.2.1 Standard Configuration Table 1.2.1-1 shows the standard configuration of the MP1800A. The latest information is available on the Anritsu website. http://www.anritsu.com/en-US/Products-Solutions/Products/MP1800A.aspx Table 1.2.1-1 Standard Configuration of MP1800A Item Model Product Name Q’ty Remarks Main unit...
  • Page 11: Options

    Chapter 1 Overview 1.2.2 Options Table 1.2.2-1 shows the options for the MP1800A. All options are sold separately. Table 1.2.2-1 Options Installed at Shipment Model Product Name Remarks MP1800A-x01 GPIB GPIB remote interface MP1800A-x02 LAN remote interface MP1800A-x07 OS Upgrade to Upgrades the OS from Windows XP to Windows 7.
  • Page 12: Specifications

    320 mm (W)  177 mm (H)  450 mm (D) (Protrusions excluded) Mass 13.0 kg (excluding modules and blank panels) Operating voltage: +10% or –15% from the rated voltage The information on options and application parts for the MP1800A is available on the Anritsu website at http://www.anritsu.com.
  • Page 13 Chapter 1 Overview 1-6.
  • Page 14: Chapter 2 Preparations

    Chapter 2 Preparations This chapter describes preparations for using MP1800A. Measures Against EOS and ESD ......... 2-2 2.1.1 How to use the GND connection cable .... 2-2 2.1.2 How to use the ESD Discharger ....... 2-3...
  • Page 15: Measures Against Eos And Esd

    (EOS) or electrostatic discharge (ESD). 2.1.1 How to use the GND connection cable There is a risk of damaging MP1800A due to EOS if MP1800A and other peripheral equipment (including experimental circuits) are not connected to the common ground.
  • Page 16 Measures Against EOS and ESD 2.1.2 How to use the ESD Discharger There is a risk of damaging MP1800A if the coaxial cable you connect to MP1800A is charged electrostatically. To prevent MP1800A from being damaged by ESD, remove electrostatic charges from the cable by using the ESD Discharger before cabling the connectors.
  • Page 17 Chapter 2 Preparations 2-4.
  • Page 18: Chapter 3 Panels And Connections

    Chapter 3 Panels and Connections This section describes panels and connections of the MP1800A. Front Panel ..............3-2 Rear Panel ..............3-4 Side Panel ..............3-5...
  • Page 19: Front Panel

    Be sure to use the wrist strap when using the MP1800A. Power switch Turns the power to the MP1800A on/off. When this switch is turned off while the power cable is connected, the Standby LED above the switch lights.
  • Page 20 Numeric keypad Numeric value or unit keys for input. USB port Two Revision 1.1 USB ports are provided. Turn the connected measuring instruments off before turning off the MP1800A. Volume Volume adjustment for measurement error sound Output key Key for turning on/off the output signal from the MU181020A.
  • Page 21: Rear Panel

    Name Function GPIB connector The GPIB connector that can be used when the MP1800A-x01 GPIB option is installed. Connect a cable to the GPIB connector on the rear panel before turning on the MP1800A. Connection after turning it on may cause failure.
  • Page 22: Side Panel

    Side Panel 3.3 Side Panel Figure 3.3-1 Side panel Six slots for installing modules are provided on the left side. See the “MP1800A Signal Quality Analyzer Installation Guide” for how to install/remove the module to/from the slots.
  • Page 23 Chapter 3 Panels and Connections 3-6.
  • Page 24: Chapter 4 Maintenance

    Chapter 4 Maintenance This section describes the maintenance of the MP1800A. Daily Maintenance ............4-2 Cautions on Storage ............. 4-2 Transportation ............... 4-3 Calibration ..............4-4 Disposal ................ 4-4...
  • Page 25: Daily Maintenance

    Chapter 4 Maintenance 4.1 Daily Maintenance  Wipe off any external stains with a cloth damped with diluted mild detergent.  Vacuum away any accumulated dust or dirt with a vacuum cleaner.  Tighten any loose parts fixed with screws, using the specified tools. 4.2 Cautions on Storage Wipe off any dust, soil, or stain on the device prior to storage.
  • Page 26: Transportation

    4.3 Transportation Use the original packing materials, if possible, when packing the MP1800A for transport. If you do not have the original packing materials, pack the MP1800A according to the following procedure. When handling the MP1800A, always wear clean gloves, and handle it gently so as not to damage it.
  • Page 27: Calibration

    Confirm the notes described in the Signal Quality Analyzer Series Installation Guide and observe national and local regulations when disposing of the MP1800A. Before disposal, dismantle or physically destroy any non-volatile memory media in the MP1800A to ensure that data in memory cannot be recovered by third parties. 4-4.