ATESS HPS20000TL-US/HPS30000TL-US
Hybrid energy system User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HPS20000TL-US and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ATESS HPS20000TL-US

  • Page 1 ATESS HPS20000TL-US/HPS30000TL-US Shenzhen Atess Power Technology Co.,Ltd 3rd floor, building 9, Henglong industrial park, the fourth industrial zone of Shuitian community, Baoan district, Shenzhen, China Hybrid energy system User Manual + 86 755 2998 8492 info@atesspower.com www.atesspower.com...
  • Page 2: Table Of Contents

    Routine maintenance 3.3 The layout of the main components 7.1 Fan maintenance 3.4 Operation mode 7.2 Regular maintenance 3.5 Battery setting 7.2 Waste disposal 3.6 Protection 3.7 Storage Appendix 3.8 Dimension 3.9 Packaging information 8.1 Specification 8.2 ATESS Factory warranty...
  • Page 3: About This Manual

    Caution,risk of electric shock All relative operations must b e p r o c e e d e d b y t h e Attention that needs to be paid when operating and maintaining ATESS professional electricians. HPS20000TL-US/HPS30000TL-US T h e r e w i l l b e r e s i d u a l...
  • Page 4: Safety Instructions

    If > Warranty service for the inverter does not contain module maintenance. necessary, you can seek help from ATESS Customer Service department. > Permission from the local utility company is required before installing the Energy Storage system and only professional personnel are qualified for the operation.
  • Page 5: Installation

    Function and safety parameters discharged. Don't change the parameters of the inverter without authorization from the local utility and ATESS Energy Technology Co., Ltd. Otherwise, it might lead to injury or equipment damage and the warranty of the inverter will be voided.
  • Page 6: Product Description

    Product description 3.1 Energy Storage system 3.3 Product specification ATESS HPS20000TL-US/HPS30000TL-US hybrid inverter is designed for energy 3.3.1 Input parameter storage system, it converts DC current generated by battery bank into AC current Inverter model HPS2 00TL-US and feed into the load/grid, also it can take power from solar inverter or grid to...
  • Page 7: Important Notes

    3.3.3 Important notes Name Description Note 1:usage restrictions Display Inverter setting, browsing and operation A.if the load connecting to the inverter is impact load, HPS20000TL- status display US/HPS30000TL-US can only supply power to 4P/6P impact load at most such as 4P/6P motor. Cable inlet and outlet For input and output power cable conneciton...
  • Page 8: Communication Port

    LOAD Communication port DC/AC breaker HPS20000TL-US/HPS30000TL-US don't have AC and DC switches or load switches, customers need to add their own switches, or buy our company to design and produce switch boxes. The AC main switch can be used to disconnect the AC interface of the inverter from the grid.
  • Page 9 3.5 Working mode 3.5.3 On-grid backup priority mode (1) Grid supplies power to load and charges battery when PV power insufficient. HPS20000TL-US/HPS30000TL-US is designed with flexible working modes: (2)When the back-flow-prevention works, PV power can meet battery charge and load power.
  • Page 10: Battery Setting

    3.5.5 On/Off-gird switch Operation logic: When grid power on, HPS can switch into on-grid mode If there is a long time before installation or operation, the ATESS HPS20000TL- US/HPS30000TL-US should be stored appropriately. automatically; when grid power off, HPS can switch into off-grid mode automatically.
  • Page 11: Packaging Information

    Products installation 3.8 Packaging information 4.1 Installation condition requirements To ensure normal operation of the machine, the installation environment is required as follows: Quantity Name Unit A. The wall for mounting HPS should be solid and able to bear the weight of HPS in the long term.
  • Page 12: Installation Environment

    4.2 Installation environment 4.3 Space requirement Although HPS is with IP54 protection level, it is not recommended to install it under When installing HPS, reasonable distance should be kept for maintenance and direct sun or direct rain/snow to ensure long term performance, below installation ventilation, please refer to below figure: environment for reference: To avoid inverter life span decrease, it is recommended to install shading shield on...
  • Page 13: Tools And Spare Parts Required For Whole Machine Installation

    4.4 Tools and spare parts required for whole machine installation Steps: A:Please drill the hole according to the hole mask. Tools and spare parts required for installation is as follows: B:Please install the expansion bolt as shown. • Hoisting crane, forklift or fork lift truck (with the capacity for bearing the weight of C:Please install the wall hanger as shown in the picture.
  • Page 14: Electrical Installation

    CAUTION! Caution, risk of danger HPS30000TL-US HPS20000TL-US Model 1. HPS20000TL-US/HPS30000TL-US of AC and DC, do not have switches or circuit breakers, customers need to add their own Grid Voltage Limit 108V-132V/216-264V 188-228V switches, or buy our company design and production switch box.
  • Page 15: Ac Side Wiring

    4.6.4 AC side wiring Step 1: Cut off the distribution circuit breaker at the DC side, and ensure that no voltage on the wire at DC side. Step 2: Confirm the battery positive and negative voltage within range with a CAUTION! multimeter.
  • Page 16: Communication

    4.6.5 Earthing Rs485 communication line uses terminal blocks at both ends, and RS485 communication lines are made by parallel connection of terminals at both ends. The length should not exceed 1000 meters. As shown in Figure 4-7-1-1. Inverter must be earthing well for safety; Please make sure of the connection between PE in power distribution cabinet and PE copper in the inverter good;...
  • Page 17: Relevant Requirements

    Pilot operation Electrical Installation Inspection The chapter will introduce the procedure of pilot operation, including checking battery voltage, input and output connecting, other preparation working. Complete and firm grounding of inverter. 5.1 Relevant requirements Grid voltage matching the rated input voltage of inverter. Correct phase sequence of grid connection, and tightening torque meeting requirements.
  • Page 18: Power On Steps

    Warning: CAUTION! • After manually shutting down, you must press the power button on When connecting the load,make sure that the three-phase of the load the LCD, otherwise cannot start automatically. is corresponding to the three-phase of the HPS, otherwise it will cause the motor to reverse.
  • Page 19: Gui Instruction

    Maintenance Table 6-1 ATESS HPS-TL LCD Menu After the LCD is powered on, go directly to the home page of the interface. At this time, wait for the internal initialization of the machine for about 1 minute(If there is no data refresh after more than 2 minutes, the serial communication between the LCD and the control board is faulty).
  • Page 20: System Settings

    6.2.3 Switch on/off page Language Settings: Select language, currently it only supports Chinese, English (default language is Chinese). You can enter this page by clicking the [Switch on/off] button in any other interface. There are the on button, the off button. Used to select power on or off operation. After selecting, select [Yes] / [No] in the pop-up sub-window to confirm.
  • Page 21: Alarm Information

    6.2.6 Operation data You can enter this page by clicking the [Run Data] button below any other interface. This page mainly displays the current energy storage power generation parameters and real-time data including grid voltage, grid frequency, grid current, DC input voltage, DC input current, chassis temperature and total power generation time, etc.
  • Page 22 Description Description Description Description PV1_OverVolt_Fault GFCI_Failure INT_BAT_OverVolt_Fault RISO_Failure INT_PV1_OverCurr_Fault BAT_MainContactor_Failure INT_BAT_OverCurr_Fault AC_BypassOverPower_Failure INT_INV_OverVolt_Fault AC_U_BypassOverPower_Failure INT_INV_OverCurr_Fault AC_V_BypassOverPower_Failure INT_BL_OverCurr_Fault AC_W_BypassOverPower_Failure INT_BUS_OverVolt_Fault BAT_ Reseverd _Failure AC_NoUtility_Fault Reseverd_Failure AC_GridPhaseSeque_Fault PV2_OverVolt_Fault AC_PLL_Fault BL_OCP_Fault AC_Volt_Unbalance_Fault PV_ OCP _Fault AC_Curr_Unbalance_Fault BMS_Communication_Fault INV_A_OCP_Fault INT_PV2_OverCurr_Fault INV_B_OCP_Fault BMS_Fault INV_C_OCP_Fault BAT_OCP_Fault AC_WU_OverVolt_Fault INT_BUS_unbalance_Fault...
  • Page 23 Description Description AC_WU_UnderVolt_Fault AC_OverTemp_Fault AC_VW_OverVolt_Fault DC_OverTemp_Fault AC_VW_UnderVolt_Fault AC_BypassOverPower_Fault AC_UV_OverVolt_Fault AC_U_BypassOverPower_Fault AC_UV_UnderVolt_Fault AC_V_BypassOverPower_Fault AC_OverFreq_Fault AC_W_BypassOverPower_Fault AC_UnderFreq_Fault EPO_Stop AC_GridCurr_DcHigh_Fault KeyEmergencyStop PV1_CurrHigh_Fault LcdEmergencyStop PV2_CurrHigh_Fault NO_Bat_Fault AC_GridCurr_High_Fault BAT_MainContactor_Fault AC_L1Curr_High_Fault AC_U_Overload_Fault AC_L1CurrDc_High_Fault AC_V_Overload_Fault AC_Overload_Fault AC_W_Overload_Fault AC_Lightload_Fault GFDI_Ground_Fault AC_BackFeed_Fault GFDI_HallSense_Fault ShineMaster_Comunicate_Fault GFDI_AirSwitch_Fault...
  • Page 24 Description 6.3.2 Severe history failure table Description PV_ Reseverd _Failure PV_Thunder_Fault IGBT_Failure AC_Thunder_Fault EEPROM_Write_Failure BAT_Thunder_Fault EEPROM_Read_Failure AC_MainContactor_Failure BusVolt_Unbalance_Fault AC_SlaveContactor_Failure INT_PV3_OverCurr_Fault GFDI_Failure DC_GFDI_Fault GFCI_Failure RISO_Failure BMS_Warning BAT_MainContactor_Failure AC_BypassOverPower_Failure Table 6.3.1 General histor y failure table AC_U_BypassOverPower_Failure AC_V_BypassOverPower_Failure AC_W_BypassOverPower_Failure BAT_ Reseverd _Failure Reseverd_Failure Table 6.3.2 Severe histor y failure table...
  • Page 25: Inverter Status

    6.3.3 Inverter status Warning: Description Do not use a gas pump to clean the fan, as this may cause damage to the fan. wait Fan cleaning or replacement: check 1. Before cleaning or replacing the fan, please make sure that the DC side and AC Grid mode side of the inverter have been disconnected.
  • Page 26: Regular Maintenance

    Table 7-2. the contract shall prevail. During the warranty period, ATESS products shall promptly present the invoice and date of purchase of the products to ATESS Service personnel during maintenance. At the same time on the product the nameplate logo should be clearly visible, otherwise it will not be repaired.
  • Page 27 Warranty condition ATESS will repair or replace the product free of charge during the warranty period; the faulty machine after replacement shall be owned by ATESS; the customer shall reserve a certain amount of time for ATESS to repair the faulty machine.