Kolibri KBR-500 Calibration Procedure

Advertisement

Quick Links

KBR-500
Calibration Procedure
The contact image sensor (CIS) within the unit is precisely calibrated at the factory. However, with regular
use, the sensor's sensitivity may alter, potentially causing False Errors. To address this, the unit can be
recalibrated using the white calibration card provided with the product.
Please follow the steps to calibrate the sensors:
1. Make sure the unit is powered ON.
2. Use the control panel to navigate: press MENU, then select Service Menu, enter the password 9999, and
choose CIS calibration. You will see a calibration screen with the instruction. "Please put the white paper"
olibri
KBR-500
3. Carefully slide the calibration card in from the front, stopping when it doesn't make contact with the
impeller wheels.
KBR500-02232024-CP
www.kolibriusa.com
olibri
olibri
KBR-500
olibri
KBR-500
© 2024 Kolibri USA

Advertisement

loading
Need help?

Need help?

Do you have a question about the KBR-500 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kolibri KBR-500

  • Page 1 CIS calibration. You will see a calibration screen with the instruction. "Please put the white paper" olibri olibri KBR-500 KBR-500 3. Carefully slide the calibration card in from the front, stopping when it doesn't make contact with the impeller wheels. olibri KBR-500 KBR500-02232024-CP www.kolibriusa.com © 2024 Kolibri USA...
  • Page 2 KBR-500 7. The calibration process is now complete. IF, after... calibrating the unit, this does not resolve the issue, please see the support section on the Kolibri USA website at www.kolibriusa.com, or contact Kolibri Support at support@kolibriusa.com for further troubleshooting.