To change the power consumption for the entire switch, perform this task:
Command
Step 1
Switch(config)# [no] power inline consumption
default milli-watts
Step 2
Switch(config)# end
Step 3
Switch# show power inline consumption default
This example shows how to set the default PoE consumption of all powered devices connected to the
switch to 5000 milliwatts:
Switch# configure terminal
Enter configuration commands, one per line.
Switch(config)# power inline consumption default 5000
Switch(config)# end
Switch#
This example shows how to verify the PoE consumption:
Switch# show power inline consumption default
Default PD consumption : 5000 mW
Switch#
To change the power consumption of a single powered device, perform this task:
Command
Step 1
Switch(config)# interface {fastethernet |
gigabitethernet} slot / port
Step 2
Switch(config-if)# [no] power inline
consumption milli-watts
Step 3
Switch(config-if)# end
Step 4
Switch# show power inline consumption
{fastethernet | gigabitethernet} slot / port
This example shows how to set the PoE consumption to 5000 milliwatts for Fast Ethernet interface 4/1
regardless what is mandated by the 802.3af class of the discovered device, or by any CDP packet
received from the powered device:
Switch# configure terminal
Enter configuration commands, one per line.
Switch(config)# interface fastethernet 4/1
Switch(config-if)# power inline consumption 5000
Switch(config-if)# end
Switch#
Software Configuration Guide—Release 12.2(25)EW
8-4
Chapter 8
Purpose
Sets the PoE consumption (in milliwatts) of all powered
devices connected to the switch. The power consumption can
range from 4000 to 15,400.
To re-enable the automatic adjustment of consumption,
either use the no keyword or specify 15,400 milliwatts.
Exits configuration mode.
Displays the administrative PoE consumption of powered
devices connected to the switch. The administrative PoE is
not the measured PoE value.
End with CNTL/Z.
Purpose
Selects the interface to configure.
Sets the PoE consumption (in milliwatts) of the powered
device connected to a specific interface. The power
consumption can range from 4000 to 15,400.
To re-enable the automatic adjustment of consumption,
either use the no keyword or specify 15,400 milliwatts.
Exits configuration mode.
Displays the PoE consumption for the interface.
End with CNTL/Z.