Download Print this page

ETI NETCOM ADH Replacement Procedure

Automatic air dehydrator air drying canisters
Hide thumbs Also See for NETCOM ADH:

Advertisement

Quick Links

MODEL ADH
NETCOM
®
AUTOMATIC AIR DEHYDRATOR WITH ETHERNET
®
ADH
NETCOM™ AUTOMATIC AIR DEHYDRATOR
AIR DRYING CANISTERS
REPLACEMENT PROCEDURE
Replacement Kit Part Number 24054
Document Part Number 24056
South Bend, Indiana USA
|
networketi.com
1
ADH INSTRUCTION MANUAL | PART NO.
24056
REV
B

Advertisement

loading
Need help?

Need help?

Do you have a question about the NETCOM ADH and is the answer not in the manual?

Questions and answers

Summary of Contents for ETI NETCOM ADH

  • Page 1 MODEL ADH NETCOM ® AUTOMATIC AIR DEHYDRATOR WITH ETHERNET ® NETCOM™ AUTOMATIC AIR DEHYDRATOR AIR DRYING CANISTERS REPLACEMENT PROCEDURE Replacement Kit Part Number 24054 Document Part Number 24056 South Bend, Indiana USA networketi.com ADH INSTRUCTION MANUAL | PART NO. 24056...
  • Page 2: Safety Information And Warnings

    SAFETY INFORMATION AND WARNINGS Abnormal Odor or Smoke Rack Mounting In the event of smoke or a burning or Before and after rack mounting the abnormal odor, immediately interrupt ADH NETCOM, ensure that the rack power to the ADH NETCOM with the is stable.
  • Page 3: Inventory List

    ADH NETCOM AIR DRYING CANISTERS REPLACEMENT PROCEDURE This procedure addresses the TOOLS REQUIRED The following tools are needed to removal and replacement of the air perform this procedure: drying canisters in an ADH NETCOM Automatic Air Dehydrator. The first • Small straight slot screwdriver section addresses the replacement •...
  • Page 4 CANISTER REMOVAL AND NOTE: REPLACEMENT Shut off machine power. To replace the air drying canisters Disconnect unit from installation (25528 and 25529) in an ADH location and move to well-lit NETCOM Automatic Air Dehydrator work bench. Make sure to retain with AC power or an ADH NETCOM all mounting hardware.
  • Page 5 Disconnect the canister power cables by loosening the captive screw at each green power connector. See Figure 2. Carefully note the connections of the existing hoses. installation will duplicate this orientation. Because they will be re- used, carefully disconnect the air Disconnect the canister power cables hoses on the inlet side (in front) of the by loosening the captive screw at each...
  • Page 6 The inlet hoses will be re-used on the Connect the outlet hoses between new canisters, but new outlet hoses the fittings on the back of the will have to be cut from the length of canisters and the solenoid valve hose included in the kit.
  • Page 7 Duplicating the original inlet hose NOTE: orientation, connect the inlet hoses between the solenoid valve barbed Refer to Table 2 below for proper canister fittings and the inlet fittings on the placement and positioning. The inlet side front side of both canisters. of the canister is the one with the electrical leads and connector.
  • Page 8 Remove and retain the four mounting To replace the air drying canisters (25529 and 25528) in an ADH NETCOM AC screws from the four corners of the NEMA, perform the steps below. protective front cover, then slowly lift the front cover, carefully flip it over, Shut off machine power by then set it down, upside down, to rest unplugging the unit.
  • Page 9 Once green power cable Disconnect the canister power connectors have been disconnected cables by loosening the captive and the tie wraps cut, lift the existing screw at each end of the green canisters out of the chassis. Carefully power connector. See Figure 2. remove the existing inlet hoses from Carefully note the position of the the canisters and retain them for re-...
  • Page 10 The inlet hoses will be re-used With the knurled side up, route the tie wraps supplied with this kit on the new canisters, but new through the canister mounting outlet hoses will have to be cut brackets located on the chassis from the length of hose included in the kit.
  • Page 11 NOTE: Position the replacement canisters on their respective mounting brackets.Install the rear canister (#1; Refer to Table 2 below for proper canister placement and positioning. P/N 25528) first and then the front The inlet side of the canister is the one canister (#2;...
  • Page 12: Questions And Comments

    Secure place ADH are registered trademarks of ETI, reinstalling the two captive screws Inc. NETCOM is a trademark of ETI, Inc. in the two outer corners of the lid. Copyright © 2012 ETI, Inc. All rights reserved. Restore machine power by plugging the unit back in.