Download Print this page

Reefe RGS11A Installation Manual / Instruction Manual

Cutter/drainage/grinder pumps
Hide thumbs Also See for RGS11A:

Advertisement

Quick Links

Pumps for the Future
CUTTER PUMPS
DRAINAGE PUMPS
GRINDER PUMPS
Instruction Manual & Installation Guide & Warranty
Ascento Group Australia 37 Export St Lytton QLD 4178
P:
1800 807 604
E:
csv@ascento.com.au
W:
www.reefe.com.au

Advertisement

loading
Need help?

Need help?

Do you have a question about the RGS11A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Reefe RGS11A

  • Page 1 Pumps for the Future CUTTER PUMPS DRAINAGE PUMPS GRINDER PUMPS Instruction Manual & Installation Guide & Warranty Ascento Group Australia 37 Export St Lytton QLD 4178 1800 807 604 csv@ascento.com.au www.reefe.com.au...
  • Page 2: Product Specifications

    REEFE SUBMERSIBLE CUTTER & DRAINAGE & GRINDER PUMPS INSTRUCTION MANUAL & INSTALLATION GUIDE PRIOR TO INSTALLATION & OPERATION The Installer must consult a WHS supervisor PRODUCT SPECIFICATIONS and/or adhere to all relevant criteria and regulations. The installer should consult an engineer for site assessment and correct installation methods.
  • Page 3: Preparing For Installation

    INSTALLATION P REPARING FOR INSTALLATION • Do not use pump in liquids other than Before Installing the pump at a work site, you water, sewage, or chemically stable will need to have the following tools and wastewater. Do not use pump in oi l , instruments ready.
  • Page 4 4 Where a float switch is attached to the WARNING: pump, ensure the float switch is free to operate without interfering with tank • When installing the pump, pay close walls, pipe work etc. attention to its centre of gravity and weight.
  • Page 5: Electrical Wiring

    8 To prevent the pump strainer stand from becoming submerged in mud, causing it to suck in debris, mount it on • If large quantities of earth are sucked a block or firm base. up, damage resulting from erosion in the pump can lead to electrical leakage and shock.
  • Page 6: Power Cable

    or unexpected starting of the pump, leading to injury or death. • Draw power from a dedicated power outlet. Sharing the outlet with other equipment may overheat the branch WARNING: outlet and could result in a fire. • Before inserting the power supply plug - When using a three pin plug, make certain the power supply is connect as described in the...
  • Page 7: Electrical Circuit Diagra Ms

    • If it is necessary to submerse the • Do not allow power cable leads or power supply plug to become wet. connection leads of the power cable in water, first seal the leads completely in • Make sure that the cable does not a molded sleeve, to prevent electrical become excessively bent or twisted, leakage, electrical shock, fire, injury or...
  • Page 8: Before Starting

    If the pump is connected to a piping system, 3 Start the pump and check the quantity the direction of rotation can be checked as of water or the discharge pressure. follows: 4 Stop the pump. 1 Start the pump and check the quantity 5 Compare the results taken under point of water or the discharge pressure.
  • Page 9 Countermeasure: If the operating current OPERATION exceeds the rated value, pump motor overload may be a cause, or there m ay be insufficient WARNING: back pressure. Make sure the pump has been installed under proper conditions as described • Do not operate the pump in dry pit, in Installation (page well, trench etc.
  • Page 10: Operating Water Level

    and restarting will result in damage to the pump. Do not continue operation at a very low lift, low water level, o r while the strainer stand is clogged with debris. Not only will performance suffefi but such conditions may cause noise, heavy vibration, and ma/functioning.
  • Page 11 1 Washing the Pump: Remove surface should be repaired by cleaning accumulated matter from the surface up that area, drying it and then of the pump and wash it with clean applying touchup coating. water. Take special care to remove any NOTE: touchup is not supplied.
  • Page 12: Troubleshooting

    case the pump will need to be dismantled STORAGE a nd repaired. When the pump is out of use for an extended • Replacing the Oil period, wash it and dry it thoroughly, then store Remove the Oil Plug and drain all the oil, it indoors.
  • Page 13 Shut off valve closed too far Open shut off (valve) operating noise. Piping resonates Improve pipe mounting 3. Correct rotation (see page 7) Reverse rotation Ascento Grou p Australia , L y tton QLD 4178 P: 1800 807 604 W: www.reefe.com.au Page 12...
  • Page 14 WARNING <'{;jt * * fie\ DO NOT TOUCH, WHEN WET-HANDED � 0 The control box or control panel 6 should be rain, snow and moisture proof. STAND ON WET GROUND POWER-OFF immediately, in case of the following cases � OVER-HEAT ■...
  • Page 15 DO NOT PASS the cable through OILY ground or on which full with ;,-, sharp objects, chemical -� -,. __ DO NOT POWER-ON ..---z. material etc. when water is iced or frozen ·{� � , ., - 1 cable DO NOT USE if cable is of : DO NOT DRAG PUMP by NAKED COPPER WIRE ·-...
  • Page 16 Pumps for the Future REEFE CUTTER & DRAINAGE & GRINDER PUMPS Warnings & Important Information 1. (al PIPE SIZE AND TYPE: Install the pump as near as possible to the discharge to reduce the length of delivery pipe. Use as few bends as possible, every bend reduces performance.
  • Page 17 REEFE CUTTER & DRAINAGE & GRINDER PUMPS WARRANTY RECORD- FILL IN AND RETAIN THIS WITH YOUR ORIGINAL PURCHASE RECEIPT PURCHASER NAME ..................PHONE NO ..........DATE OF PURCHASE .../ .../ .... DEALER/STORE NAME ................DEALER SUBURB/TOWN ..............PHONE NO ............
  • Page 18 The following conditions are in addition to your statutory rights. This warranty covers failure due to manufacturing defects within a 12 month period for REEFE ™...