MaxVac SV1-430-MBS20 Instruction Manual

MaxVac SV1-430-MBS20 Instruction Manual

Industrial vacuums

Advertisement

Quick Links

INDUSTRIAL
VACUUMS
SV1-430-MBS20
SV1-430-MBS
SV1-430-MLS
INSTRUCTION
INSTRUCTION
MANUAL
MANUAL
GEBRAUCHS-UND
GEBRAUCHS-UND
WARTUNGSANLEITUNGEN
WARTUNGSANLEITUNGEN
INSTRUCTIEHANDLEIDING
INSTRUCTIEHANDLEIDING
ISTRUZIONI PER L'USO
ISTRUZIONI PER L'USO
E LA MANUTENZIONE
E LA MANUTENZIONE
INSTRUCTIONS D'UTILISATION
INSTRUCTIONS D'UTILISATION
ET D'ENTRETIEN
ET D'ENTRETIEN
INSTRUCCIONES DE USO
INSTRUCCIONES DE USO
Y MANTENIMIENTO
Y MANTENIMIENTO

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SV1-430-MBS20 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MaxVac SV1-430-MBS20

  • Page 1 INDUSTRIAL VACUUMS SV1-430-MBS20 SV1-430-MBS SV1-430-MLS INSTRUCTION INSTRUCTION MANUAL MANUAL GEBRAUCHS-UND GEBRAUCHS-UND WARTUNGSANLEITUNGEN WARTUNGSANLEITUNGEN INSTRUCTIEHANDLEIDING INSTRUCTIEHANDLEIDING ISTRUZIONI PER L’USO ISTRUZIONI PER L’USO E LA MANUTENZIONE E LA MANUTENZIONE INSTRUCTIONS D’UTILISATION INSTRUCTIONS D’UTILISATION ET D’ENTRETIEN ET D’ENTRETIEN INSTRUCCIONES DE USO INSTRUCCIONES DE USO...
  • Page 2 SV1-430 INDUSTRIAL VACUUM RANGE SV1-430 RANGE MAX-VAC.COM...
  • Page 3: Table Of Contents

    WARNINGS ENGLISH The appliances described in this manual are suitable for: Vacuuming dust and liquids. INSTRUCTION Professional use (e.g. hotels, schools, hospitals, factories, shops, offices and rental agencies). MANUAL The 'M' Category is suitable for the separation of dry powders (as long as they are not explosive, inflammable and/or carcinogenic) with maximum permeability <0.1% and MAC (Maximum Allowable Concentration) ≥0.1mg/m WARNINGS...
  • Page 4: Risk Of Falling

    Use an extension cable only if in perfect conditions and make sure that the Repairs may only be carried out by specialists who keep the original spare parts cross-section is appropriate for the power of the appliance plus the power of the supplied by the manufacturer.
  • Page 5 Maintenance and cleaning must be carried out in a room with adequate ventilation and in such a way as not to endanger the operators or other persons. If the power cable is damaged, it must be replaced by the manufacturer or approved technical service centre Clean the place where maintenance is carried out in order to prevent that or in any case by a person with similar qualification so hazardous substances are dispersed into the environment.
  • Page 6: Technical Specifications

    TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS SV1-430 MBS20 SV1 430 MBS 20 Power supply voltage 230 V~ 1. Vacuum’s head with commands Frequency 50/60 V-Hz 2. Filter chamber 3. Dirt collection container Power Rating 2.4-3.4 kW-HP 4. Container closing hook Maximum airflow approx 380m 5.
  • Page 7: Operation

    OPERATION Before turning the vacuum cleaner on again, ensure that the pump has been stopped completely. Controls 1. I/0 Switch: START/ STOP first motor To move the vacuum cleaner, use the special handles situated on the front part of the machine. 2.
  • Page 8 Manual Filter Cleaning Inserting and locking the bin To clean the filter cartridge, the vacuum cleaners of the 430MBS/MLS series, are Follow the steps below to insert and lock the bin: equipped with the AirPulse Filter Cleaning system. The system works thanks •...
  • Page 9 The AirPulse Filter Cleaning system only works with the vacuum Inserting and locking the bin cleaner switched on. Follow the steps below to insert and lock the container: • Insert the container under the vacuum cleaner, aligning the closing hooks (A) with the corresponding parts (B) located on the filter chamber Emptying the container Depending on the type and quantity of material being vacuumed, it is necessary to...
  • Page 10: Maintenance

    Special vacuum maintenance must be carried out solely by specialised technicians authorised by MAXVAC. Should maintenance operations or repairs be carried out, all contaminated objects must be adequately cleaned, placed in waterproof bags and disposed of in This section describes the checks and routine maintenance operations required to compliance with the regulations in force.
  • Page 11 • Keep unauthorised personnel out of the work area. (information c/o MaxVac). This operation is the sole responsibility of an • Ensure that the necessary tools are in good conditions and readily available to electrician.
  • Page 12: Filter Replacement

    • Lock the filter to the cage by tying the special laces on the bottom side MANUAL FILTER REPLACEMENT • Insert the filter with ring and cage inside the filtering chamber, paying particular attention to align the cage to the filter shaking lever •...
  • Page 13 AIRPULSE FIL TER REPLACEMENT To reassemble the filter, operate in reverse order: • Insert the new filter in the support ring and lock it by means of the fastening Wear appropriate PPE (dust mask, latex gloves, goggles, etc.). clip (H) •...
  • Page 14: Troubleshooting

    • Switch the vacuum on, immediately assessing Clogged suction hose Check the suction its efficient operation. hose and clean it. Excessively noisy Motor(s) failure Contact the MAXVAC motors technical service centre Bag external flap Bag supporting ring SV1-430 RANGE MAX-VAC.COM SV1-430 RANGE MAX-VAC.COM...
  • Page 15: Ec Declaration Of Conformity

    Do not dispose of electrical appliances with household waste! In compliance with European Directive 2012/19/EU on waste electrical and electronic equipment (WEEE) and its implementation in accordance with national law, electric tools that have reached the end of their lifecycle must be collected separately and returned to an environmentally compatible recycling facility.
  • Page 16 Mülibodenstrasse 3 CH-8172 Niederglat Zürich, Schweiz +41(0) 43 411 4195 max-vac.com Version 1.1...