Download Print this page
IKA KS 130 control Operating Instructions Manual
IKA KS 130 control Operating Instructions Manual

IKA KS 130 control Operating Instructions Manual

Hide thumbs Also See for KS 130 control:

Advertisement

Quick Links

KS 130 control
KS 130 control NOL
KS 260 control
KS 260 control NOL
HS 260 control
HS 260 control NOL
Betriebsanleitung
Ursprungssprache
Operating instructions
Mode d'emploi
使用说明
DE
3
EN
18
FR
33
ZH
48

Advertisement

loading
Need help?

Need help?

Do you have a question about the KS 130 control and is the answer not in the manual?

Questions and answers

Summary of Contents for IKA KS 130 control

  • Page 1 KS 260 control KS 130 control KS 260 control NOL KS 130 control NOL HS 260 control HS 260 control NOL Betriebsanleitung Ursprungssprache Operating instructions Mode d’emploi 使用说明...
  • Page 2: Table Of Contents

    Source language: German Safety instructions In order to be able to use the device properly and safely, every user must first Contens read the operating instructions and observe the safety instructions contained Page therein. Take care of these operating instructions and keep them in a place EU Declaration of conformity where they can be accessed by everyone.
  • Page 3: Intended Use

    A (factory setting). Additional hazards to the user may occur if inflammable materials are used dur- The KS 130 control / KS 130 control NOL and KS 260 control / KS 260 ing the shaking operation.
  • Page 4: Unpacking

    The speed-controlled external rotor asynchronous motor enables precise speed device in reference to how it stands with the adjustable feet. adjustment in the range from 80 to 800 rpm (KS 130 control / KS 130 To do this, turn the appropriate device...
  • Page 5: Display

    Display Switching on Switch on the device via the power switch (rocker switch) on the front of it. After switching on, a self-test is carried out, all display elements light up, a short signal sounds and the safety-relevant functions are checked. ...
  • Page 6: Working With The Device

    Shaking function without timer If the shaking function is started by pressing the left rotary knob, the left display  shows the actual speed and the shaking function indicator LED lights up. The right display shows the time value. The device regulates the speed to reach the set speed. The display shows the Speed limit stored actual speed for 4 seconds and only the shaking function indicator LED lights up.
  • Page 7: Operating Modes

    Switching the operating mode: Operating modes The following steps are required to switch the operating modes: a.) Turn off the device with the power switch. The device can be operated in the modes described below: b.) Press and hold both rotary knobs and turn on the device with the power switch. After about 1 second, the rotary knobs can be released.
  • Page 8: Setting The Lock Function

    Audible signal function, setting saved Locking function deactivated Note: Safety-relevant signal tones, such as error messages or the timer expiration, Note: If no changes are made in 3 seconds, the setting is saved and the LED of cannot be switched off. the set indicator stops flashing.
  • Page 9: Attachments

    For gentle agitation at low speed, for example for Petri dishes or culture flasks. The dish attachments are equipped with an antislip sheet that prevents the dish Attachments recommended by IKA must be connected to the shaking table to from moving around during the agitation process.
  • Page 10: Supported Weight (Load)

    AS 260.2 Holding bracket adapter Supported weight (load) With additional holding brackets (AS2.1, AS2.2, AS2.3, AS2.4 and AS2.5) the holding bracket adapter is suitable for working with round flasks, measuring flasks In order to ensure safe and secure operation, the shaker must only be operated and Erlenmeyer flasks.
  • Page 11: Error Codes

    AS 130.4 Reactant glass adapter Error codes 2500 If an error code is encountered, an audio warning signal is generated and the error code appears on the display field. First, please try to continue operating by turning 2000 the device off and back on again. If it is still not possible to eliminate an error after 1500 an extended wait, please contact our service department.
  • Page 12: Interface And Outputs

    • RTS: (Pin 7) LOW (positive tension) / PC may send Interface and outputs • RTS: (Pin 7) HIGH (negative tension) / PC may not send • CTS: (Pin 8) LOW (positive tension) / PC recipient The device is equipped with a 15-pin SUB-D connector on the rear side of the •...
  • Page 13 NAMUR Instructions Function Display RMP_STOP_X Switching off ramp function. additional Rated value=0 (Ramp is maintained, that means , ramp can be restarted with RMP_START_X. IN_PV_X Reading the real-value. RMP_PAUSE_X Stopping the ramp function. OUT_SP_X n Setting the actual value to n up to a maximum of Freezing of real rated value and real ramp segment the set upper speed limit.
  • Page 14: Communication Between Laboratory Instrument And Pc

    For this, you need register on our website MyIKA first. This adaptor is required to connect the 15-pin connector to a 9-pin interface. After registering your device IKA will inform you about available updates for your PC 2.1 Cable devices.
  • Page 15: Maintenance And Cleaning

    - Do not allow moisture to get into the device when cleaning. - If a different cleaning or decontamination method than the method defined General accessories by IKA is planned, the user must ascertain with IKA that this method does STICKMAX Adhesive mat not damage the device.
  • Page 16: Technical Data

    Technical data KS 130 control KS 260 control HS 260 control HS 260 control NOL KS 130 control NOL KS 260 control NOL Design voltage 230 ± 10 % / 115 ± 10 % Frequency 50 / 60 Motor rating input...