Download Print this page

Description; Overload Protector; Control Board Indications; Dimensions - Nederman FilterCart Advanced+ User Manual

Hide thumbs Also See for FilterCart Advanced+:

Advertisement

Available languages

Available languages

3 Description

FilterCart Advanced+ filters out pollutants such as
fumes and dust. The FilterCart Advanced+ is only in-
tended for indoor use and is designed for extraction
and filtration of welding fumes. It must not be used
for the extraction of fluids.
NOTE!
The FilterCart Advanced+ does not have any
connections for the channelling of exhaust air.

3.1 Overload protector

See
Figure
4. The FilterCart Advanced+ is equipped
with an overload protector which means that the
power will disconnect automatically if the fan motor is
overloaded.
• C: Red light emission light indicates: disconnected
power and released overload protector.
• D: Button for re-setting the overload protector.

3.2 Control board indications

See
Figure
6.
A When the mains plug is connected the light emis-
sion diodes indicate fixed light and an alarm signal
sounds for a short time.
B
The light emitting diode indicates a blinking green
light: The FilterCart Advanced+ has been connec-
ted to the mains (stand by).
C
As the FilterCart Advanced+ has been started the
light emission diode indicates fixed green light.
The fan is in operation.
FilterCart Advanced+
D The FilterCart Advanced+ is ready for use and
after a while, the light-emitting diode indicates
fixed green light. After use for a certain time, the
airflow will be reduced through the extraction arm
and the pressure drop will increase, which will res-
ult in having to change the filter cartridge.
E
The light emitting diodes indicate fixed light: The
pressure drop has increased. Pre-warning for
changing the filter cartridge.
F
The light-emitting diodes indicate fixed light
and after about 30 s an intermittent alarm signal
starts. Change the filter cartridge. If you want to
finish the work in progress before the filter cart-
ridge is changed, the alarm signal can be stopped
by pushing once on the start button. The alarm
signal activates after about 10 minutes. Push-
ing twice on the start button makes a fan stop. As
an alternative, the fan can be stopped with the
switch on the Fume Extractor hood.
G
The light emitting diode indicates blinking red
light = alarm memory. The FilterCart Advanced+
has been stopped after the alarm start (accord-
ing to above), for example at work shifts. The filter
cartridge has to be changed.
H The light emitting diode indicates fixed red light
and an intermittent alarm signal starts. The over-
load protector has been released. Examine the
reason and reset the overload protector by push-
ing the "Motor Protector Reset"- button.

3.3 Dimensions

See
Figure
1.
A: Horizontally swivelling arm.