SC92 Portable Conductivity Meter
Start-up and Safety Precautions
IM 12D03E02-01EN
IM 12D03E02-01EN
1st Edition

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SC92 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for YOKOGAWA SC92

  • Page 1 User’s Manual SC92 Portable Conductivity Meter Start-up and Safety Precautions IM 12D03E02-01EN IM 12D03E02-01EN 1st Edition...
  • Page 2 Otherwise battery leakage may occur, causing damage to or malfunction of the meter. • Use both meters and sensors made by YOKOGAWA. Otherwise, it will result not only voiding of our warranty, but also may impair the safety and performance of the instrument.
  • Page 3 • No part of the user’s manuals may be transferred or reproduced without prior written consent from YOKOGAWA. • YOKOGAWA reserves the right to make improvements in the user’s manuals and product at any time, without notice or obligation. • If you have any questions, or you find mistakes or omissions in the user’s manuals, please contact our sales representative or your local distributor.
  • Page 4: Safety Precautions

    The product is provided on an “as is” basis. YOKOGAWA shall have neither liability nor responsibility to any person or entity with respect to any direct or indirect loss or damage arising from using the product or any defect of the product that YOKOGAWA can not predict in advance. IM 12D03E02-01EN...
  • Page 5: Compliant Standards

    Regulation(EC) 1907/2006 CE marking products n Authorized Representative in EEA The Authorized Representative for this product in EEA is Yokogawa Europe B.V. (Euroweg 2, 3825 HD Amersfoort, The Netherlands). n Identification Tag This manual and the identification tag attached on packing box are essential parts of the product.
  • Page 6 Control of Pollution Caused by the Product This is an explanation for the product based on “Control of Pollution caused by Electronic Information Products” in the People’s Republic of China. 产品中有害物质的名称及含量 有害物质 部件名称 铅 汞 镉 六价铬 多溴联苯 多溴二苯醚 (Pb) (Hg) (Cd) (Cr (VI)) (PBB) (PBDE) 本体...
  • Page 7: Instrument Check

    Upon delivery, unpack the instrument carefully and inspect it to ensure that it was not damaged during shipment. If damage is found, retain the original packing materials (including the outer box) and then immediately notify YOKOGAWA sales office. n Checking the model and suffix code Check the model and suffix code on the name plate affixed to the back side of the meter and sensor cable as shown in Figure 1.
  • Page 8: Checking Package Contents

    Part number Quantity NaCl Standard solution 0.1 mol/l NaCl K9221ZA * 1 pcs solution for calibration 250 mL *: You can download the Safety Data Sheet (SDS) from the following website: https://www.yokogawa.com/library/. IM 12D03E02-01EN 1st Edition : Aug. 30, 2024-00...
  • Page 9: Inserting The Batteries

    Preparation Insert batteries and connect the sensor. Set up according to your preference. For details, see the User’s Manual IM 12D03E02-02EN. 2.1 Inserting the Batteries Put AA alkaline batteries into the meter. (1) Unscrew the battery cover on the back of the meter counter-clockwise to unlock the battery cover.
  • Page 10: Connecting Sensor

    2.2 Connecting Sensor Connect a conductivity sensor to CH2. Connectable one is SC92SN. It is no problem to connect the sensor while the power is ON. Connect the sensor to the meter properly as follows. (1) Align the slot of the electrode connector with the pin of the electrode connector on the meter and insert it.
  • Page 11 2.3 Setup You can setup the followings if you like. Refer to the IM 12D03E02-02EN for details. P1 COND (Conductivity setup): Set cell constant, Select conductivity unit, Calibration mode setting, Temperature compensation factor setting, Reference temperature setting, Clear Calibration Data P2 DATA (Data setup): Data log interval setup, All data clear P3 GEN (General setup):...
  • Page 12: Operation

    NOTE Operate the keys with your fingers. l How to change the measurement parameter SC92 can measure both conductivity and resistivity. When in measurement mode, press the MODE key to switch measurement parameters. How to measure (1) Remove the cap of sensor when the sensor has one.
  • Page 13: Saving Data

    (3) In the default auto stable mode, an automatic stability check starts and flashes. When the measured value has stabilized, the switches from blinking to lit to indicate the stabilized measured value. after stability Figure 5 Conductivity measurement example (auto stable mode) Saving data In a measurement mode, press the ENT key.
  • Page 14: Auto Calibration

    Standard Solution Calibration The default setting for calibration method is automatic calibration. Auto calibration After immersing the conductivity sensor in the solution, press the CAL key. The calibration method (AUTO) being set is displayed. blinks, and the stability check of the measured value begins.
  • Page 15: Maintenance And Storage

    Maintenance and Storage Maintenance See IM 12D03E02-02EN for details. • After the measurement is finished, wash off any contaminant or measurement solution adhering to the sensor with water and store it. • Wipe off any contaminant on the body with a soft cloth. If the contamination is severe, use a neutral detergent.
  • Page 16: Revision Record

    Revision Record Aug. 2024/1st Edition Newly published Yokogawa Electric Corporation 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750, JAPAN http://www.yokogawa.com/ IM 12D03E02-01EN 1st Edition : Aug. 30, 2024-00...