YOKOGAWA EXA100 Series Quick Manual
YOKOGAWA EXA100 Series Quick Manual

YOKOGAWA EXA100 Series Quick Manual

Panel mount conductivity measurement system

Advertisement

Quick Links

EXA100 Series
This Quick Manual briefly explains the operation,
calibration and routine maintenance of the EXA Series
SC100 Converter and the dedicated conductivity sensor,
SC10XB. Please read the appropriate user's manuals
thoroughly before using this system.
References: User's Manuals
SC100 Panel Mount Conductivity Converter:
SC10XB Conductivity Sensor:
1. Key Operations
• To cancel the operation: Simultaneously press [ ] and
[ ] keys.
• To move from measurement display to setup display :
Hold down [ENT] key for at least 3 sec.
• To move from measurement display to calibration display :
Hold down [ ] key for at least 3 sec.
• To move from setup/calibration display to measurement
display :
Hold down [ ] key for at least 3 sec.
Main functions of keys
[ENT] key : Confirms the status or setting.
[ ] key: Moves up a menu item or increases the setting.
[ ] key: Moves down a menu item or decreases the setting.
2. Start-up
For start-up instructions, refer to the SC100 Panel Mount
Conductivity Converter's User's Manual, IM 12D11A01-01E.
3. Calibration
(Using Standard Calibration Solution)
Refer to Chapter 6 of the SC100 Panel Mount Converter's
User's Manual, IM 12D11A01-01E.
* Calibration should be performed if the cell constant has changed due to prolonged operation.
Rinse the conductivity
sensor well with water
or appropriate solution.
Press [ ] key
for 3 sec.
EXA
SC100
EXA
SC100
µS/cm
µS/cm
S1
S3
mS/cm
S1
S3
mS/cm
S2
S4
S2
S4
CANCEL
Calibration
SET
CAL
MEAS
ENT
Display Top
Measurement
Display
Press [ENT]
key once.
* Conductivity meter does not require calibration using standard solution as routine maintenance if the
correct cell constant has been defined upon start-up.
* For details on the calibration using standard solution, refer to Section 6.5 of the SC100 Panel Mount
Converter's User's Manual, IM 12D11A01-01E.
SC100 Panel Mount Conductivity Measurement System
IM 12D11A01-01E
IM 12D11C01-01E
Wipe thoroughly after rinse,
and then soak the sensor in
the standard solution.
Water
Standard solution
Data updated
Press [ENT]
EXA
SC100
key once.
µS/cm
S1
S3
mS/cm
S2
S4
Main display stops
Calibration result
flashing and sub-display
is reflected to the
is flashing.
measured value.
Display and Operation Keys
Status Display
• Status of
contact output
(specified by
S1
suffix code)
S2
SET
ENT
[ ENT ] key
Alphanumeric Display Table
Alphabet
LED
A
B
C
D
E
F
G
H
I
J
K
L
M
Press [ENT] key twice.
Main and sub displays
Press [ENT]
flash upon each press.
key once.
EXA
SC100
µS/cm
S1
S3
mS/cm
mS/cm
S2
S4
Wait until reading
has stabilized.
Press [ENT]
EXA
SC100
EXA
SC100
key once.
µS/cm
S1
S3
mS/cm
S1
S3
S2
S4
S2
S4
[ Quick Manual
Main Display
SC100
EXA
• Conductivity reading
during measurement
• Setting and data during
calibration/setup
Sub-Display
µS/cm
• Temperature during
S3
mS/cm
S4
measurement
• Parameter during setup
CANCEL
CAL
MEAS
[ ] key
[ ] key
Alphabet
LED
Number
N
0
O
1
P
2
Q
3
R
4
S
5
T
6
U
7
V
8
W
9
X
Y
Z
EXA
SC100
µS/cm
S1
S3
mS/cm
mS/cm
S2
S4
1st digit in Main
Decimal point
display is flashing.
is flashing.
Move the decimal point
using [ ] and [ ] keys.
Press [ENT] key to confirm.
Replace the sensor in the process.
EXA
µS/cm
mS/cm
Press [ ] key
S1
S3
S2
S4
for 3 sec.
SET
ENT
Measurement
Display
IM 12D11A01-11E 1st Edition: Mar. 2003
]
LED
Set the conductivity
value of the standard
solution using [ ] and
[ ] keys.
EXA
SC100
µS/cm
S1
S3
mS/cm
S2
S4
SC100
µS/cm
mS/cm
CANCEL
CAL
MEAS

Advertisement

loading

Summary of Contents for YOKOGAWA EXA100 Series

  • Page 1 EXA100 Series SC100 Panel Mount Conductivity Measurement System [ Quick Manual Display and Operation Keys This Quick Manual briefly explains the operation, calibration and routine maintenance of the EXA Series Main Display SC100 SC100 Converter and the dedicated conductivity sensor, •...
  • Page 2 Zero Calibration (Air Calibration: Eliminating an error resulting from wiring capacity) Refer to Section 6.4 of the SC100 Panel Mount Converter's User's Manual, IM 12D11A01-01E. Rinse the conductivity sensor well with water Dry it thoroughly. or appropriate solution. Water Press [ ] key Press [ENT] Press [ ] key.

This manual is also suitable for:

Sc100