WARNING:
power to the system before installation, maintenance, cleaning, or any other
system modification could result in serious injury or death.
AVERTISSEMENT :
Négliger de débrancher toutes les sources d'alimentation du système avant
l'installation, l'entretien, le nettoyage ou toute autre modification du
système peut causer des blessures graves ou la mort.
De-energize main feed to ArcSystem and follow appropriate Lockout/Tagout
procedures as mandated by NFPA 70E. It is important to note that electrical
equipment such as breaker panels can present an arc flash hazard if
improperly serviced. This is due to the high amounts of short-circuit current
available on the electrical supply to this equipment. Any work must comply
with OSHA Safe Working Practices.
WARNING:
accessible power disconnect device cannot be serviced or operated safely.
AVERTISSEMENT :
d'utiliser ou de réparer les circuits installés sans qu'un dispositif de
déconnexion de l'alimentation ne soit accessible.

Installation Requirements

• Indoor installation only: 0–40°C (32–104°F), 5–95% non-condensing humidity.
• Dry locations only.
• Installation location must support the weight of the luminaire, driver, and applicable
mounting hardware.
CAUTION:
spaces with restricted air flow. Enclosing the luminaires or drivers
temporarily or permanently may cause damage to the luminaires or drivers.
Installation Spacing - High Output Luminaires
If you are installing ArcSystem Pro One-Cell High Output luminaires, plan the luminaire and
driver locations around the required spacing listed below.
Install with minimum spacings between
a. Center-to-center of adjacent luminaires: 609.6 mm (24 in);
b. Top of luminaire to overhead building member: 76.2 mm (3 in);
c. Luminaire center to side building member: 304.8 mm (12 in);
Assurer les dégagements minimaux suivants
a. Entre l'entraxe des luminaires adjacents 609.6 mm (24 po)
b. Entre le dessus du luminaire et l'élément de charpente se trouvant au-dessus 76.2 m
(3 po)
c. Entre le centre du luminaire et un élément de charpente 304.8 mm (12 po)
System Overview
RISK OF DEATH BY ELECTRIC SHOCK! Failure to disconnect all
RISQUE DE MORT PAR DÉCHARGE ÉLECTRIQUE!
RISK OF ELECTRIC SHOCK! Circuits that are installed without an
RISQUE DE DÉCHARGE ÉLECTRIQUE! Il est imprudent
ArcSystem luminaires and drivers are not suitable for use in
7